  • I replace a faulty hi pressure switch on an Air Conditioning system

ความคิดเห็น • 118

  • @Beasus_
    @Beasus_ 4 หลายเดือนก่อน +2

    Appreciate the video, man. Ignore the negative comments; this video was exactly what I needed, clearly explained the disassembly process, and gave cautionary advice when needed. Keep it up.

  • @rollzolo
    @rollzolo 3 ปีที่แล้ว +5

    Carrier 20 plus years. Never maintained. Works like the first day. Most high bless my home

  • @TheGgin
    @TheGgin 6 ปีที่แล้ว +2

    Nice job and video, good to see some units still have Schrader cores on the pressure switches as some are brazed in now and I think Trane has the 1/4" flare, but a tag that at least tells you there is no core. Makes it easy not to pump down or recover to replace this switch.

    • @thehvachacker
      @thehvachacker  6 ปีที่แล้ว +4

      I wish everyone used pins if the switches are wrenched on. A brazed on safety switches like Carrier and Rheem use at least don't loosen and leak. I find its easier to disconnect wiring when they fail and add an external pressure switch on a swivel t on the service port.

    • @robertjackson7590
      @robertjackson7590 ปีที่แล้ว

      @@thehvachacker this is what you need to do a video on...

  • @justanotheryoutuber5228
    @justanotheryoutuber5228 2 ปีที่แล้ว +5

    Nice to have it Schradered in vs brazed in

  • @WaterBearOfficial
    @WaterBearOfficial ปีที่แล้ว +1

    De minimis ! Good to know theres a schrader valve behind it. You should consider getting a small tripod for better camera angles.

  • @TheReason101
    @TheReason101 9 หลายเดือนก่อน +3

    How dou you know if it has a schrader?

  • @sknight0391
    @sknight0391 5 ปีที่แล้ว +1

    I'm with you man...."My Knee Hurts too!"

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +1

      Our knees weren’t designed for how we work

  • @MultiMaverix
    @MultiMaverix 2 ปีที่แล้ว +1

    Thank you very helpful.

  • @robjaws1000
    @robjaws1000 4 ปีที่แล้ว +3

    I need to change the High Pressure Switch on a Lennox 13ACX-030-230-12. The factory switch is Sensata model #100103-03. I understand the original switch is obsolete and was replaced by an automatic reset switch. I wasn't getting cooling, so I went outside and realized nothing was running. Started troubleshooting and found I wasn't getting 24VAC at the control contact. Pressed the reset hard and could get it to start but it was flaky and would just shut back off. I cleaned the coils, which weren't too bad, but still no luck. So I bypassed the switch just to make sure it was the high pressure switch shutting it off. It was that switch and it sounded fine, so I let it run for a few minutes and was getting cold air and normal amperages. I am going to have an AC tech check the pressure for good measure, but I suspect it is just a bad switch. Do you know if my model has the shrader valve under the high pressure switch? It is threaded on, but I can't find that info anywhere online. Thanks!

    • @poljam6171
      @poljam6171 4 ปีที่แล้ว

      Hi what replacement part number for Sensata #100103-03?thanks

    • @robjaws1000
      @robjaws1000 4 ปีที่แล้ว +2

      @@poljam6171 The replacement sensor is Lennox 93W01 Sensata 100087-12. My unit did have a shrader core for anyone looking for it (to prevent loss of refrigerant).

    • @cxbxtx
      @cxbxtx 3 ปีที่แล้ว

      Hi Rob, how can we find out whether the AC unit has schrader valve or not? Mine is of model 13ACX-048-230-17.

  • @shawnmiller8185
    @shawnmiller8185 ปีที่แล้ว +3

    Kool I just had to know it had scrader behind it

  • @marlenecalvert6673
    @marlenecalvert6673 3 ปีที่แล้ว +15

    NO clue WHAT you were doing?! This video just shows the "general area" of the switch (bottom of the AC) and the backs of your hands?

  • @ilovenythismuchilovenewyor5801
    @ilovenythismuchilovenewyor5801 3 ปีที่แล้ว +2

    so why did you have to change the hp switch?? was the fan and compressor short cycling on and off ??

  • @renecuevas4128
    @renecuevas4128 2 ปีที่แล้ว +3

    Found most AC units in fl with High Pressure switches in BYPASS MODE

  • @search4truth616
    @search4truth616 4 ปีที่แล้ว

    The Lennox unit I just repaired at my home has a pressure switch with a reset switch on it. The outdoor unit would not power on at all. I pushed the button on the High Pressure Switch and the unit started running again. I felt a distinct click when I pushed the button which you can not feel in subsequent pushing.

  • @ali1339
    @ali1339 4 ปีที่แล้ว +2

    Hi
    Hi,
    A mice or a chipmunk chewed my outside unit high pressure switch's wires and disconnected them, so my outside unit is not running anymore. Can I reconnect them with wire nut or soldering or even with electrical tape? if so, does it make any effect on how the switch supposed to work?
    Thanks

    • @thehvachacker
      @thehvachacker  4 ปีที่แล้ว

      You can reconnect the wires if enough is left for a splice. Just don’t short the wire to ground or you will burn up a transformer. If the chipmunk hasn’t done that already

    • @ali1339
      @ali1339 4 ปีที่แล้ว

      Both of wires have the same color - Yellow with a Red stripe - can I reconnect them in any order? I'm not sure which one goes to which.

    • @thehvachacker
      @thehvachacker  4 ปีที่แล้ว +1

      That’s wired in series u can reconnect either way

    • @sonyaduncan5963
      @sonyaduncan5963 4 ปีที่แล้ว

      D

  • @caru3257
    @caru3257 ปีที่แล้ว

    I don’t remember how I lost your videos but I think it was when I replaced a phone.

  • @fishyouall
    @fishyouall 4 ปีที่แล้ว +1

    Great Video!
    I just figured out that my problem is high pressure switch . how do I reset it on old system? I cant locate any buttons. are they resetable? or I need to replace it?
    Thanks in advance!

    • @999raiderz
      @999raiderz 4 ปีที่แล้ว

      Some are resettable and some aren't. There will be a button on the top of the switch if its resettable.

  • @davidgutreuter4191
    @davidgutreuter4191 4 ปีที่แล้ว

    I have a ac/heat pump. The control board shows a high pressure switch fault. The system works fine in the ac position but when you switch the thermostat to heat it blow the 3amp fuse on the control board.

  • @amodio79
    @amodio79 3 หลายเดือนก่อน

    Any chance you could tell me if Ducane has a scrader valve? Thanks

  • @FEZLERKINS2011
    @FEZLERKINS2011 3 ปีที่แล้ว +3

    I agree with the comment below......Please consider the person watching your video.............I cannot watch the video all over the place!

    • @FEZLERKINS2011
      @FEZLERKINS2011 3 ปีที่แล้ว +2

      Also, remember the people watching your video are not professionals so you need to fully explain and show what you are doing!

  • @Rine23
    @Rine23 5 ปีที่แล้ว +2

    I’d start using gloves when you touch refrigerant. Plenty of guys bust my balls for it but trust me, over years of work in the field you will develop a nasty chemical burn that will never go away. My dad has it and my old boss has it.

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว

      It is a good idea yet connecting refrigerant hoses is a lot safer today than when I first started. I have gotten frostbite burns from refrigerant. Today we have ball valves and low loss fittings. When I started your hi side hose was discharging all the liquid out of it when disconnecting. Today we can safely connect and disconnect with almost no refrigerant coming out

  • @sanjeevmalhotra9326
    @sanjeevmalhotra9326 4 ปีที่แล้ว +1

    How can I tell if my LP Switch has a schrader valve. It has a hex nut below but I am not sure if it is directly bolted on the pipe, or on a schrader valve. It is a Lennox XC17-036 unit from Year 2013.

    • @thehvachacker
      @thehvachacker  4 ปีที่แล้ว +2

      it has a Schrader pin under the lp switch. Is your switch faulty or your system pressure low. Lennox had a class-action lawsuit over leaking evap coils. That would give a low-pressure shutdown. Also, cold morning have caused the 5 lp switch openings that cause the lp lock out also

    • @sanjeevmalhotra9326
      @sanjeevmalhotra9326 4 ปีที่แล้ว +1

      @@thehvachacker I will be measuring the system pressure in a day or two as my set of gauges are with someone who is out of town. I have two similar units and yes on one unit the Evaporator coil was replaced under warranty.
      Once I know the system pressure, I will know exactly the root cause. I did bypass the LP switch, and the compressor, and fan turned up, but I did not run for more than 45 sec so I could not measure the temp diff to see if we were cooling.
      Question - what is Lennox policy on warranties when we drop the stupid maintenance plans from installers which end up being more than the cost of the system over time.

    • @sanjeevmalhotra9326
      @sanjeevmalhotra9326 4 ปีที่แล้ว +1

      I checked the Class Action suit. My first replacement was done under warranty, if this failed I am over the 5 year from date of install claim - lets see
      topclassactions.com/lawsuit-settlements/closed-settlements/145764-lennox-evaporator-coil-class-action-settlement/

    • @sanjeevmalhotra9326
      @sanjeevmalhotra9326 4 ปีที่แล้ว +1

      The vapor side pressure is 25, and cannot test anything else as the system is shut down due to the fact the LP switch is open. I suspect a leak. Guess this might rule out the switch and problem lies somewhere else.

    • @thehvachacker
      @thehvachacker  4 ปีที่แล้ว

      The system is shut down due to low pressure. 25 is the reason the system is shut down on a low pressure fault

  • @SuperSincere1
    @SuperSincere1 3 ปีที่แล้ว +1

    Quick question- do you HAVE to use a indoor freeze stat with low ambient pressure switch?

    • @thehvachacker
      @thehvachacker  3 ปีที่แล้ว

      I would always recommend it. If your running an ac system in cold weather situations.

  • @renecuevas4128
    @renecuevas4128 2 ปีที่แล้ว

    We use Swivel T in HP switches or Low. But they Leak for sure

    • @robertjackson7590
      @robertjackson7590 ปีที่แล้ว

      I'm helping a friend solve this problem on a Trane that's out of warranty and was going to tee on th service fitting and was worried about that they might leak over time. What's the solution? Leave the Tee off and screw the switch straight to the service fitting?

  • @charley_1421
    @charley_1421 5 ปีที่แล้ว +2

    I’m new in the field what is that relay wired to do?

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +1

      That is a hi-pressure switch. If the head pressure/ hi side pressure gets too high it opens the 24 volts circuit to the contactor in the condenser to shut down the compressor.

  • @hg2.
    @hg2. 4 ปีที่แล้ว +1

    Phew - need to know that wiring.

  • @davidgutreuter4191
    @davidgutreuter4191 4 ปีที่แล้ว

    I have a nordyne ac/heat pump. The control board shows a high pressure switch fault but the ac and heat still seem to be working normally. Should I go ahead and replace the switch.

    • @thehvachacker
      @thehvachacker  4 ปีที่แล้ว

      Need to know the pressure to see if it’s the switch or something else.

  • @HellTriX
    @HellTriX 3 ปีที่แล้ว +1

    This looks like the High pressure switch that I need, What is this part number?

    • @ricardofletes6629
      @ricardofletes6629 2 ปีที่แล้ว

      Same did you find out the part

    • @robertjackson7590
      @robertjackson7590 ปีที่แล้ว

      A service tech said that in Florida the HPS was bypassed on most bc it will "never" see a high pressure issue. Looks good on paper but in the real world the system will only fail in a way that drops pressure.

  • @geecrawdad
    @geecrawdad 5 ปีที่แล้ว +1

    Would you know if a 1993 Tempstar 5500, Model # CH5524VKA2 has a low pressure switch that has a schrader valve? Or how I could find out ? I can see that it does screw on like yours. I don't want to find out the hard way. Thanks!

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว

      I am not sure you. Why are you trying to take it off?

    • @geecrawdad
      @geecrawdad 5 ปีที่แล้ว +1

      @@thehvachacker. Thanks. Well, I'm not really having a problem yet but this unit hasn't been serviced in over 12 years and I don't know how long before that. So because of its age I'm hoping to prevent any problems. I've replaced the contactor, the run cap, added a start cap & relay. I also intend to replace the defrost board, coil temp sensor and the low pressure switch. I guess this is what happens when you retire - you look for things to do even if they don't need to be done. I did find out that I could put the pressure sensor on the low side service port if I want to avoid the possibly missing schrader valve. By the way, this pressure sensor measures open. I thought it is supposed to be closed. Or does that change after it's installed in the system? Thanks!

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +1

      It needs to have pressure on it to close the switch . Those switches rarely ever go bad. That I never changed one for preventive reasons. You can put an access t on the suction valve port or spin it off and if gas keeps coming out spin it right back on. Then you might need some gas if anything escaped. Have you tried to download the installation or service manual for that system? Most have a pin under but not all. It’s usually a gamble that most techs take having alittle gas to put in if no pin was there.

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +1

      Why change anything just keep the parts and if it breaks change it? I always tried to work on the if not broke don’t touch it motto. Too many times I try to play with something and create more unnecessary work and headaches.

    • @geecrawdad
      @geecrawdad 5 ปีที่แล้ว

      @@thehvachacker Yeah, I know you're right. I was thinking that the system is so old, something is bound to go. Maybe I'll just wait cause I have a similar tendency to try to solve one problem and create two. I do have the manual another tech gave me a link for. Do you think I should read it? Just kidding! Thanks for your responses. By the way, if you're still in the mood to answer newbie questions - what's the dense black material around the coil temp sensor? Is it insulation or just to keep it in place?

  • @Arieldny
    @Arieldny 4 ปีที่แล้ว +1

    Please explain the wiring better. Tell us more of what’s going on.

  • @randallowens7691
    @randallowens7691 3 ปีที่แล้ว +1

    Do you not put nylog on yours sorry if not spelled right

    • @thehvachacker
      @thehvachacker  3 ปีที่แล้ว

      Sometimes yet nylon eats up gaskets on my tools. Many times I just use vacuum pump oil works just as good as nylog

  • @jesushuerta3890
    @jesushuerta3890 2 ปีที่แล้ว

    How do you bypass you high pressure switch

  • @biblebloopers946
    @biblebloopers946 2 ปีที่แล้ว +1

    Man, i have a tough time watching your videos because you hold your breath so much and then you let the air out of your lungs. Constant gasping for air in every video. But i do like your videos

    • @JPNZenii
      @JPNZenii 2 ปีที่แล้ว +2

      That’s probably the dumbest complaint on the internet.

  • @pablogaviria9265
    @pablogaviria9265 2 ปีที่แล้ว +2

    WOW. I’m getting DIZZY Watching this Video !

  • @cooldude2245
    @cooldude2245 2 ปีที่แล้ว

    If that switch is bad will the contactor pull in?

    • @jamessherman3197
      @jamessherman3197 2 ปีที่แล้ว +3

      No. They are connected in series on your 24v circuit to the contactor relay. To diagnose a bad switch, check continuity through both legs. They are typically normally closed.

  • @KaioStryker
    @KaioStryker 5 ปีที่แล้ว

    Hmmm, my tech said he'd have to do about 4-$500 worth of removing refrigerant to replace the switch and then putting refrigant back in the system.

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +3

      It depends on the machine. Some of these switches are brazed to the copper and if that the case they need to pull a good vacuum which might take 2-5 hours. Every system is designed different

    • @KaioStryker
      @KaioStryker 5 ปีที่แล้ว

      The HVAC Hacker thanks, it looks like it’s connected to the copper.

    • @ilovenythismuchilovenewyor5801
      @ilovenythismuchilovenewyor5801 3 ปีที่แล้ว

      stop thinking every serviceman is a crook .... we paid to go to school or put in our time to learn to fix these type issues so we are worth every red cent . go ahead and go buy the 1000s we spend in tools too just so u can use tben once in a a blue

  • @leou84
    @leou84 ปีที่แล้ว +4

    Worst instruction video yet. Wow!

  • @MrIslos
    @MrIslos 5 ปีที่แล้ว

    My presure switch opens and close every second, do you think that is a bad switch? Will any switch work or do I have to get exact the same?

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว

      You need to get the switches rated and designed for your systems operating pressure

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +1

      Also verify it's not a pressure issue yet an issue with the switch

  • @jimmydavis6954
    @jimmydavis6954 2 ปีที่แล้ว

    I can't tell whether you had to pump it down or not it looks like you didn't

    • @thehvachacker
      @thehvachacker  2 ปีที่แล้ว

      I did pump the system down.

    • @JMPIMP254
      @JMPIMP254 2 ปีที่แล้ว

      @@thehvachacker why if you just had to replace a hps?

  • @lex6794
    @lex6794 ปีที่แล้ว +1

    I can't tell where the second wire goes in you gotta redo this video.

    • @FrizzyGaming_
      @FrizzyGaming_ ปีที่แล้ว +1

      Facts , video was a complete waste of time smh

    • @austinamd4416
      @austinamd4416 12 วันที่ผ่านมา +1

      Well just check where wires are connected on old switch and put them back

    • @lex6794
      @lex6794 12 วันที่ผ่านมา

      @@austinamd4416 Thanks man

  • @99neworleans
    @99neworleans 7 หลายเดือนก่อน +2

    You know how to fix that conditions but you don't know how to make a video, it needs to be edit when you get home

    • @jacobbell1934
      @jacobbell1934 27 วันที่ผ่านมา

      Nah it’s fine

  • @BongBlasta
    @BongBlasta ปีที่แล้ว +4

    camera angles suck!

  • @waylandleong
    @waylandleong 15 วันที่ผ่านมา

    Sorry but I can't see anything didn't get anything out of this video you should redo it

  • @Yankee3164
    @Yankee3164 4 ปีที่แล้ว

    How many hours should it take to replace a faulty high pressure switch in a couple years old Trane residential unit?
    I ask because I just had one replaced and it took the tech 3 hours. Your video makes it look like only a few minutes to complete the work.

    • @thehvachacker
      @thehvachacker  4 ปีที่แล้ว +1

      That depends on if the switch is threaded on and has a Schrader pin behind it. If not system refrigerant needs to be recovered, then system evacuated, and recharged.

    • @Yankee3164
      @Yankee3164 4 ปีที่แล้ว +2

      @@thehvachacker So, 3 hours could be a reasonable time?

    • @jonlovean018
      @jonlovean018 4 ปีที่แล้ว +1

      @@Yankee3164 yes absolutely, I've quoted 4 hours before if its brazed in. If there is refrigerant to be recovered that has to happen, then sweat the old one out, install the new one, pressure test and then evacuate. Then comes start up and testing 3 to 4 hours is fair

  • @sherriethames6503
    @sherriethames6503 23 วันที่ผ่านมา

    Not trying to be negative but if you're going to produce a teaching video, you have to figure out how to film your work rather than the ground between your knees.. When you reviewed it, you knew it wasn't good enough.

  • @luvazpe
    @luvazpe 3 ปีที่แล้ว

    Price range of this job?

    • @AJ-ox8xy
      @AJ-ox8xy ปีที่แล้ว

      That depends on where you live

    • @AJ-ox8xy
      @AJ-ox8xy ปีที่แล้ว

      Average HPS costs around 50$. Assuming it is a normal switch. The job amount can vary from as little as 200$ to as much as 1200$. It all depends on where you live, how much competition you have, and how much the average client makes a year.

  • @FLdb-wj4wc
    @FLdb-wj4wc ปีที่แล้ว

    Why am i being quoted $900 to replace mine

    • @thehvachacker
      @thehvachacker  ปีที่แล้ว +4

      do they need to remove the refrigerant from your system to replace. This system has one of the easiest switches to replace, many are brazed/ welded to the copper pipe

  • @EFD620G
    @EFD620G 5 ปีที่แล้ว +2

    Cutting the wires and removing about half their length would have made it a neater job, instead of just coiling up the extra.

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +1

      Just putting the system back to how Lennox designed it

    • @frankduarte4270
      @frankduarte4270 5 ปีที่แล้ว +5

      Who’s gonna be checking how neat it is

    • @thehvachacker
      @thehvachacker  5 ปีที่แล้ว +1

      Easier to do amp draws if the wire has some play

    • @5822huron
      @5822huron 5 ปีที่แล้ว

      @@frankduarte4270 preach

  • @dennisz494
    @dennisz494 2 ปีที่แล้ว +4

    i shut this off it was so damn terrible.

  • @djkaneck1
    @djkaneck1 4 หลายเดือนก่อน +2

    Sloppy

  • @adelhassan8216
    @adelhassan8216 3 ปีที่แล้ว

    سبلت 3 طن عطل E1

  • @user-bx4zk7bv1n
    @user-bx4zk7bv1n ปีที่แล้ว +3

    Terrible video... couldn't you have found someone to hold the camera so we could see what you were doing?

  • @djkaneck1
    @djkaneck1 4 ปีที่แล้ว +8

    Worst camera shoot of all time, garbage

  • @nhojcam
    @nhojcam 2 หลายเดือนก่อน +1

    i currently have a very slow leak on my low pressure switch. was quoted $708 to replace it (June '24) from a quite reputable dealer here in my area. i said to the tech, "get outt'a here. that can't be that much." he said, "no really, that's what it costs." then, i said to him, "you are misunderstanding me. i said to get outt'a here. that means...pick up all your shit, put it away, clean up, get in your brand new company truck, and get the F outt'a here."
    i'm sorry, but i don't care good or reputable the person is who is performing the replacement... i don't even care if you can actually walk on water and your name on your birth certificate is 'AC Jesus Christ!'... there is no way on planet earth that a $30 pressure switch replacement should cost $708. I get it... evacuate the lines / save the R410a that's in the system, torch the old switch off, solder the new one on, pull vacuum to confirm good repair, and recharge the system. 1 person for maybe 2 hours total. $325 is what it should cost plus the cost of topping up any lost refrigerant. all you AC companies and techs out there charging this ridiculous amount of money can just go.suck.an.egg. #yousuck #thief #gotohell

    • @AndresH92
      @AndresH92 2 หลายเดือนก่อน +6

      Do it yourself then 😂....you forgot to mention that you had no clue what was wrong with your unit in the first place and needed an expert to figure it out. That knowledge isn't free remember that!

    • @404derpnotfound
      @404derpnotfound 2 หลายเดือนก่อน +2

      It's people like you that makes me money when your shit breaks and needs to be replaced cos you were too cheap to fix it. Spend a dollar to save a dime. Thanks for putting bread on my table 👏

    • @jacobbell1934
      @jacobbell1934 27 วันที่ผ่านมา

      Lol do it yourself then guy. Why you calling people out there if you have such a bad attitude. I think you need to get over yourself a little to a lot

  • @MikeHemby-wx1xv
    @MikeHemby-wx1xv ปีที่แล้ว +1

    It might help if your hands weren't in the way all the time. Nice try though