Sir, aac block ko hum residential area main use kr skte hai kya ? Because residential area main aas padose ke ghr ekdum sat ke bnte hai, toh incase agr padose vala apne ghr ka renovation ya pura tod kar bnata hai toh apne ghr main aac block wall main crack ya wall failure to nhi hoga?
sir, block jointing mortar adhesive use karna chahiye, mortar nahi kyo block ka properties alag hai mortar se bonding nahi ho pata hai future me cracks aa sakte hai
If beam is at 4ft and you want to extend room size to 5ft, can we use aac block there? it is just partition wall for kitchen and should be use band at 4ft height for this partition wall also?
भाई मुझे भी मकान बनाना है क्या aac block का घर मजबूत रहेगा मकान भूकम के झटको से गिर तो नही जायेगा और aac block गाटर पटिया का 2 से 3 मंजिल का मकान ठीक रहेगा aac block में। चटक तरेड तो नही आयेगी aac block ओर 2 से 3 मंजिल में कितनी AAC block लग जायेगी
Sir, aac block ko hum residential area main use kr skte hai kya ? Because residential area main aas padose ke ghr ekdum sat ke bnte hai, toh incase agr padose vala apne ghr ka renovation ya pura tod kar bnata hai toh apne ghr main aac block wall main crack ya wall failure to nhi hoga?
Please drop a video on normal plaster and ready mix plaster
sir, block jointing mortar adhesive use karna chahiye, mortar nahi kyo block ka properties alag hai mortar se bonding nahi ho pata hai future me cracks aa sakte hai
I am suffering from tht cracks so many leaks in my building....This brick has ruined my future Fuck AAC bricks
If beam is at 4ft and you want to extend room size to 5ft, can we use aac block there? it is just partition wall for kitchen and should be use band at 4ft height for this partition wall also?
Yes AAC BLOCKS will crack if used over a height of 1200 mm
6 layer k baad 1 rcc band aata hai
भाई मुझे भी मकान बनाना है क्या aac block का घर मजबूत रहेगा मकान भूकम के झटको से गिर तो नही जायेगा और aac block गाटर पटिया का 2 से 3 मंजिल का मकान ठीक रहेगा aac block में। चटक तरेड तो नही आयेगी aac block ओर 2 से 3 मंजिल में कितनी AAC block लग जायेगी
Honeycomb are seeing. It is not good for the strength of the wall or building
Matlab
Usko kahase meligi
Yes celery leak hui hai
Can i use the acc blocks below the plinth level wall which we construct underground. Kindly reply to me ASAP.
No it's not load bearing properly use 9" red brick or chira stone
can rcc band be given without column? we are building partition wall but it does not have column in the ends
Colums Is must because bar of bend transfers load to columns
1000 block me kitane rooms banege
It depends upon the size of the aac block.
5 rooms
Room size?.??
Around 800 sq feet area if 200 x 150 x 600 used
Sill band mein sariya bhi daala jaata hai kya ?
Yes
bend me sariya bhi jayega kya
Yes
Dada aac bolokes kotay paojace bolbe dada
না বলবো না
@@janasmp6985😢 bolo na
Bhai 10×10 ft ghor me AAC block kitne logega. Block ki size ki hisab se batao please 🙏
100 pcs lagege ji size 25” length ,8” height , 4” width ki size k block
@@lakshaychoudhary5378 30x30 me kitne pcs lagenge
Aac block useless hai
Kyu