#22 -Analog Input Scaling Function | 4-20 mA & 0-10V Analog Signal|Delta PLC | P-2 | (HINDI)

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 พ.ค. 2020
  • #Anlog_Signal_4_20mA #Analog_Input_0_10V #DELTA_PLC_SCALING #ANALOG_PROGRAMMING_DELTA_PLC #DELTA_SCALING
    In this Video We are going to learn How to Use analog signals in our DELTA PLC. And how to use scaling function including programming for 0-10v/ 4-20mA input.
    These videos are only to understand how Embedded, Robotics, and Automation work for Education purposes.
    Hit Like button, Share, Comment
    Please Subscribe for more with BELL Icon
    Don't miss out on new Videos.
    *If Anyone has Any Copyrights issue please Send
    Email - teckybuzz@gmail.com
    TH-cam - / teckybuzz
    Instagram- / tecky.buzz
    Facebook- / tecky.buzz.3

ความคิดเห็น • 108

  • @shaileshvora3278
    @shaileshvora3278 2 ปีที่แล้ว +2

    Dear sir, Simply superb. I have never seen anything like this . Very nice, very much simple way to explain. I need such videos for EH series PLC & functions "TO" & "FROM"

  • @sandhyaprabhu6996
    @sandhyaprabhu6996 27 วันที่ผ่านมา

    Fabulous sir.🙏🙏

  • @PadaliyaDarshan
    @PadaliyaDarshan 3 ปีที่แล้ว +2

    good learning for all ........
    and continues go ahead..........

  • @mohammadpathan4668
    @mohammadpathan4668 4 ปีที่แล้ว

    Nice explanation ! Thank you .

  • @NadeemQuamar.
    @NadeemQuamar. ปีที่แล้ว +1

    Thank YOU sir

  • @AR-ELECTRICALS-HV
    @AR-ELECTRICALS-HV หลายเดือนก่อน

    Very good

  • @parasramthakur7106
    @parasramthakur7106 3 ปีที่แล้ว

    Thank you Sir for guide PLC programming learning

  • @semalkumar5633
    @semalkumar5633 4 ปีที่แล้ว +1

    Very good explanation..

  • @Ammeribne
    @Ammeribne 3 ปีที่แล้ว

    Really its helpful ❤️❤️

  • @youtubecreators1997
    @youtubecreators1997 ปีที่แล้ว

    Great sir

  • @rathankumar6066
    @rathankumar6066 4 ปีที่แล้ว

    Thank you sir..

  • @rajusoni6540
    @rajusoni6540 2 ปีที่แล้ว

    very informativ video

  • @vijaybakshi8888
    @vijaybakshi8888 2 ปีที่แล้ว

    excellent teacher.

  • @nehrunagar6191
    @nehrunagar6191 3 ปีที่แล้ว +1

    very nicely explained :)
    keep making more videos on Plc programming!

    • @mohammadkaisaralam354
      @mohammadkaisaralam354 ปีที่แล้ว

      sir how to use gain for vfd?and how to control gain in hmi and plc.plz sir i want to know.

  • @made2automate
    @made2automate 3 ปีที่แล้ว +3

    Great Videos Sir:), Learning from you!

  • @sharadpawar5552
    @sharadpawar5552 ปีที่แล้ว

    Thank u thank v much Sir

  • @sharadpawar5552
    @sharadpawar5552 ปีที่แล้ว

    Sir or advance me lectures banao..
    Ur lectures in details sir

  • @electronicsideas1361
    @electronicsideas1361 3 ปีที่แล้ว

    FANTASTIC VIDEOS. I NEED ECODER SETTING AND SCALING

  • @sagarengineering2941
    @sagarengineering2941 4 ปีที่แล้ว

    nice video

  • @rjcarillo1414
    @rjcarillo1414 ปีที่แล้ว

    Can you speak in English please? Your videos are extremely good and it would help a lot of people if you can speak in English

  • @vanipuntambekar1180
    @vanipuntambekar1180 3 ปีที่แล้ว +1

    very helpful videos :)
    kindly make videos on DCS as well
    Thank you!

  • @Logicmart5754
    @Logicmart5754 2 ปีที่แล้ว

    Nice explanation in simplest way. Just improve your voice, it's a bit low.

  • @rajeshkumarmauryamaurya380
    @rajeshkumarmauryamaurya380 3 ปีที่แล้ว +1

    Sir delta plc mein Modbus communication ka video banaiye

  • @excellentenginers
    @excellentenginers 3 ปีที่แล้ว +1

    aapka analog scaling part 22 dekha bahot acchi tarah se aapne samjaya hey.hame aur bhi jankari chahiye to aapse kaise le sakte hey.from.kirti sanghvi

    • @TeckyBuzz
      @TeckyBuzz  3 ปีที่แล้ว

      simple or videos dekh kr 😊 insta pr follow karo agar apko koi question hai wahan drop kar sakte jo comment m drop kar sakte

  • @kishanmarvaniya1489
    @kishanmarvaniya1489 2 ปีที่แล้ว

    Dear sir
    Load cell module ke upar aesa ku6 video banao

  • @RanveerSingh-bb4nm
    @RanveerSingh-bb4nm 3 ปีที่แล้ว

    sir ,
    make videos
    scaling of load cell with hmi and plc programming

  • @husum7875
    @husum7875 ปีที่แล้ว

    Sir. How can i do for reading two 4..20ma transmitters.. Iam using tp70p-21ex1r.. And thank you very much for helping me

  • @mariyamelectricaltutorial818
    @mariyamelectricaltutorial818 2 ปีที่แล้ว +1

    Sir pressure transmitter value 4ma to drive 50hz per ghumna chahiye agar value badhati hai to 50 se kam hona chahiye is ka program bna digiye sir

    • @TeckyBuzz
      @TeckyBuzz  2 ปีที่แล้ว

      dm on my instagram

  • @alaminkhan965
    @alaminkhan965 2 ปีที่แล้ว

    Delta invertor ms300 auto troly program waring rev fwr

  • @arifulislamarif4009
    @arifulislamarif4009 7 หลายเดือนก่อน

    Dear Sir,
    sir i have a question If I want to increase or decrease frequency in Delta VFD by counter then how to program. I have a sensor that will count 200 then give an output, then when it counts 300 it will give an output, then when it counts 500 it will give an output, based on this output the frequency should be changed. How to do this program.

  • @zafariqbal8953
    @zafariqbal8953 3 หลายเดือนก่อน

    D1110 main jo value a rhe hy wo to decimal plus float value hy lekin is main to MOV ki command use ki hy to float value lo lost ho jae ge. jaise 0 to 10 volt main MOVR use kia hy k point k baad value b ae to uper phir DMOVR kiun use ni ki??????

  • @karneashok
    @karneashok 4 ปีที่แล้ว +1

    Hi, can you brief us on controlling two pump one by one according to pressure transmitter. on/of should be as per set time

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว +2

      yes. apko pressure transmitter se value read karni hai uski scaling karni hai then apni desired range k according range compare karao . let maan lo 10 bar pr apko motor on chahiye so compare logic se timer run karao jitni der k liye apko motor on chahiye utna timer set kariye or timer Ki TT bit se output le lijye

  • @AR-ELECTRICALS-HV
    @AR-ELECTRICALS-HV 2 หลายเดือนก่อน

    Can you program the plc as per my requirment

  • @shailendravishwakarma8445
    @shailendravishwakarma8445 3 ปีที่แล้ว

    Sir Delta plc me load cell scaling ke bare me btaye

  • @chickenz4604
    @chickenz4604 3 ปีที่แล้ว +1

    NICE VIDEO Sir! Thx! I am also using Delta PLC but i have difficulty for the analog input current from the flowmeter. When there is no water flow at all the flow should be zero right, but the raw value still generates numbers fluctuates from 0-35 (Range should be 0 - 32000). And when I measure the current, it shows 4mA or minimum value. Please help me!

    • @TeckyBuzz
      @TeckyBuzz  3 ปีที่แล้ว

      Do proper scaling

    • @chickenz4604
      @chickenz4604 3 ปีที่แล้ว +1

      @@TeckyBuzz its already proper the scaling

  • @manumichael7870
    @manumichael7870 2 ปีที่แล้ว +1

    I have one dowt . CT coil how to connect Delta PLC. And volte meter also

    • @TeckyBuzz
      @TeckyBuzz  2 ปีที่แล้ว

      anlog CT and voltmeter aata hai usko analog channel se input lo

    • @manumichael7870
      @manumichael7870 2 ปีที่แล้ว

      Up koi analog ct and volt meter model bolekatho meruko help ojayeka

  • @vaibhavkumbhar3151
    @vaibhavkumbhar3151 ปีที่แล้ว

    Flow totalizer function kaise use kare

  • @roymaghraj9456
    @roymaghraj9456 3 ปีที่แล้ว +1

    Hi ...I understand a little hindi... wish it be in English.. well explained.
    How do you change existing input configuration 0 to 10v into 4 to 20ma and vice versa on wpl version 2.50

    • @TeckyBuzz
      @TeckyBuzz  3 ปีที่แล้ว

      D1115 move 0 for volt move 1 for current

  • @ujjwaldhibar9489
    @ujjwaldhibar9489 10 หลายเดือนก่อน

    sir i can not configure between DVP14SS211T and with 2no. DVP08SN11T & 2nos. DVP04AD-S.
    here 5 nos analog i/p and 18 nos digital o/p , I NEED ALSO WITH ADDRESSING, PLEASE HELP ME.

  • @shohaghossain9157
    @shohaghossain9157 9 หลายเดือนก่อน

    Why use memeory bit M1000?
    Why not use M0.0?
    Anyone can help me.

  • @sheharyarkhan4429
    @sheharyarkhan4429 ปีที่แล้ว +1

    2 float values mei comparison kese krskte hain
    Jese mei chah rha hn k 4.75 se 9.5 tk meri output active rhay aur jese hi uske opar value jae mera output reset hjae

    • @TeckyBuzz
      @TeckyBuzz  ปีที่แล้ว

      float compare bit hai

    • @sheharyarkhan4429
      @sheharyarkhan4429 ปีที่แล้ว

      @@TeckyBuzz bana lia mei ne danish bhai, mei ne dosra comparison lagakey max value 9V set kri aur output reset kradia

  • @ishtiyaqueansari9106
    @ishtiyaqueansari9106 2 ปีที่แล้ว

    danis sir kiya delta plc dvp12sa2 me analog hote hai agal se mudul us kar ke

    • @TeckyBuzz
      @TeckyBuzz  2 ปีที่แล้ว

      no sa2 analog support ni hai

  • @vaibhavkumbhar3151
    @vaibhavkumbhar3151 ปีที่แล้ว

    Hi sir

  • @vimal5820
    @vimal5820 4 ปีที่แล้ว +1

    By default voltage selection mode me rehta hai, ya hame value move Kara k mode change Karna padta hai

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว +1

      default voltage pr rehte hain bht se plc EX SX wagera m 0 by default hota hai lkin ap move kar k sure bhi kar sakte ho

    • @chiragpanchal4031
      @chiragpanchal4031 4 ปีที่แล้ว

      Sir, agar 1 set karte hai to all 4 analog channel 4-20ma hi Leni padegi ya voltage ki channel bhi le sakte hai?

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว +1

      @@chiragpanchal4031 yes but kisi kisi plc m seprately option available hai

  • @RajeshYadav-be7ds
    @RajeshYadav-be7ds 2 ปีที่แล้ว

    Boss mai dharm Kate ka kam krta hu mujhe hmi,plc use kr k kata me kaise use krte hai iska program kaise banega

  • @RajeshYadav-be7ds
    @RajeshYadav-be7ds 2 ปีที่แล้ว

    Boss pracyice k liye koi delta ki plc batayiye jo analog and digital support kre

    • @TeckyBuzz
      @TeckyBuzz  2 ปีที่แล้ว

      koi bhi model le lo SE SS EX jo apke budget m ho

  • @gurjeetsaini2711
    @gurjeetsaini2711 2 ปีที่แล้ว

    If there is multiple sensor in field than each sensor will have individuals coding???

    • @TeckyBuzz
      @TeckyBuzz  2 ปีที่แล้ว

      yes
      you have to address each

  • @RahulSingh-fz7sy
    @RahulSingh-fz7sy 4 ปีที่แล้ว +1

    Sir.... Please is video series Ko complete Karo aap analog pura Karo aap

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว +1

      is video ko dekho sari cheez cover kari hai

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว +1

      is series m or video bhi hain

    • @RahulSingh-fz7sy
      @RahulSingh-fz7sy 4 ปีที่แล้ว +2

      Ohkk.... Sir pr jo level sensor hote h control valve hote h unse plc se connection kar ke... Vfd Ko kese control Karte h

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว +1

      @@RahulSingh-fz7sy is video k last m yehcheez bhi apko smjh aa jayegi kaise use kar sakte ho next videos m output k upr hoga

    • @RahulSingh-fz7sy
      @RahulSingh-fz7sy 4 ปีที่แล้ว +1

      Sir... 8962665784 mere what's up no h please aap connected rahiye mere se.. Me bhi industry me job karta hu aap ke video help Karte h bhut

  • @vertexmfg
    @vertexmfg 2 ปีที่แล้ว +1

    Hello Sir

  • @ishtiyaqueansari9106
    @ishtiyaqueansari9106 2 ปีที่แล้ว

    sir mujhe delta plc and hmi chaye kaha se milengi me saudi me ho 🤗🤗 sir koi online site batao please

  • @chiragpanchal4031
    @chiragpanchal4031 4 ปีที่แล้ว +1

    Sir, how to find resolution in plc? Pls let me know

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว

      resolution sensor ka sensor ki data sheet/ manual m hoga or plc ka model ka according uski manual m hoga

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว

      mostly plc ka resolution 10 - 12 bit ka hota hai

    • @chiragpanchal4031
      @chiragpanchal4031 4 ปีที่แล้ว +1

      Thank you sir,
      I have 14SS2 delta plc. Muje 2 analog input use karne hai. Muje kon se type ka expansion module use karna chahie?

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว

      @@chiragpanchal4031 DVP04 le lo

  • @ishtiyaqueansari9106
    @ishtiyaqueansari9106 3 ปีที่แล้ว +1

    my dear sir please dop as series ka software kase download kare please help 🥺🥺🥺

  • @abhilashmasavalli1832
    @abhilashmasavalli1832 3 ปีที่แล้ว +1

    Keep your camera little bit down.

  • @MaheshPatil-ne8uq
    @MaheshPatil-ne8uq 4 ปีที่แล้ว +1

    DMOVR F2.000E +03 D10 what is problem

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว

      float point set karo 3 pr yani decimal ki 3 values hi show kare

  • @user-xc9bc1km2l
    @user-xc9bc1km2l 7 หลายเดือนก่อน

    Mpg program sir

  • @sanjuvlog3460
    @sanjuvlog3460 ปีที่แล้ว +1

    Sir ye ek channel k liye hai

  • @shopatsuthar2495
    @shopatsuthar2495 3 ปีที่แล้ว +1

    Sir your email

    • @TeckyBuzz
      @TeckyBuzz  3 ปีที่แล้ว

      See in description

  • @cuteaadya2891
    @cuteaadya2891 4 ปีที่แล้ว +1

    What is your instagram id

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว +1

      tecky.buzz

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว

      just replace 10 with your value

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว

      please watch till end

    • @cuteaadya2891
      @cuteaadya2891 4 ปีที่แล้ว +1

      I watched till end. Mere matlb h ki agr voltage 10 voltage se extra measure kari ho like 230V or 440V

    • @TeckyBuzz
      @TeckyBuzz  4 ปีที่แล้ว

      @@cuteaadya2891 haha good question
      i think abhi koi esa sensor aaya ni hai market jo analog signal ki value +24 v se uper deta ho
      in future koi aaya toh plc ki range honi chahite itni 220v 440v honi chahiye ap uske according scaling kar apaoge
      waise kuch device aate hain jo high volt ko convert karte hain low voltage m
      like 0-220v voltmeter convert kar deta 0-10 v then ap is supply ko apne plc m scaling karte like 0-2000 bits ko 0 220v
      😀😀 i hope smjh aaya hoga
      220v plc k channel pr kabhi kat dena plc kharab ho jayegi

  • @rajeshkumarmauryamaurya380
    @rajeshkumarmauryamaurya380 3 ปีที่แล้ว +1

    Sir delta plc me MFM meater ka video banaiye