Combine 2 PZEM Energy Meters online monitoring with Blynk App using NodeMCU for Solar.

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 มิ.ย. 2020
  • This project shows you how to DIY online monitoring for more than 1 PZEM meter using Blynk App, NodeMCU and 2 PZEM Energy Meters. The two PZEM meters can be of PZEM-014 or PZEM-016 AC Energy Meters, PZEM-017 DC Energy Meters or combined of AC and DC Energy meter. The system just send data from the commercial Energy Meter to the Blynk Server which has a web interface for online monitoring through its app. It is very suitable for recording Solar PV System or household energy or power consumption. For more information, kindly go to my blog page.
    Solarduino blog page : solarduino.com/how-to-combine...
    We would need readers like you to support us in order to keep growing. You can support us in the following ways :
    1) Donate & fund raising
    2) Purchase components from our Aliexpress Affiliate links
    3) Like & Share videos & posts
    Aliexpress Affiliate Links :
    1) Aliexpress Mainpage - s.click.aliexpress.com/e/_d6XZp98
    2) AC Meter with LCD Display - s.click.aliexpress.com/e/5UAzX0Xm
    3) DC Meter with LCD Display - s.click.aliexpress.com/e/DWRlRbHQ
    4) PZEM-016 AC Meter - s.click.aliexpress.com/e/BHG96Oso
    5) PZEM-017 DC Meter - s.click.aliexpress.com/e/pN9UUmMs
    6) Serial to RS485 converter - s.click.aliexpress.com/e/5yJDPXSC
    7) Node MCU - s.click.aliexpress.com/e/_sMC6Vj
    8) Node MCU Base - s.click.aliexpress.com/e/_dUP917q
    9) Ferrule Lugs & Crimper Sets -s.click.aliexpress.com/e/nX0FGyuC 10) Terminal Plier Set - s.click.aliexpress.com/e/_d6ozNbf
    11) Arduino Starter Kit - s.click.aliexpress.com/e/_d71x0Cg
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 35

  • @Solamiser
    @Solamiser 7 หลายเดือนก่อน

    Thanks very much for this video. With your help I have managed to get a modified version of your sketches working on a Clone Nano using Softwareserial and your modified Modbusmaster library. My plan is to use the 2 x PZEM016 to measure solar generated power and load power. Subtracting one from the other I can get grid import/export power. By using a software PID controller (part of Nano sketch) with a fixed power setpoint of zero, I can automatically adjust the battery charging rate to achieve zero grid import or export where possible during daylight hours whilst keeping the battery topped up as much as possible. This should reduce my utility bill. Thanks again for your help. Your videos and write ups are very clear and useful. Keep up the good work!

  • @haitran3724
    @haitran3724 3 ปีที่แล้ว

    good men

  • @fouriegildenhuys374
    @fouriegildenhuys374 9 หลายเดือนก่อน

    Thanks for the great video. Will this have bi-directional capabilities? For example, will the PZEM-016 (AC) be able to measure when I am consuming or feeding energy to the grid?

  • @magnetus26
    @magnetus26 ปีที่แล้ว

    this is so nice I was looking for something like this thank you
    I do have a question how hard is to make 2 x AC and 1 x DC code?
    also i dont know anyyhing about blynk, I like to know if I use this code can I monitor outside my home network for example from work using my cell phone data or from my parents using their wifi
    thank you so much

  • @richmartin7293
    @richmartin7293 ปีที่แล้ว +1

    Hi
    The mobile app no longer available in the United State for iPhone
    Is there another app I can used

  • @chalongjitome2222
    @chalongjitome2222 3 ปีที่แล้ว +1

    hi I am not able to solve the address collision problem, sometimes it can show both AC and DC, and after some time the value cannot be saved. Where should I solve the problem?

  • @GordonLiaw
    @GordonLiaw 3 ปีที่แล้ว

    nice vid! Will I be able to use this to monitor my 3 phase energy usage at home?

    • @solarduino1374
      @solarduino1374  3 ปีที่แล้ว

      Hi, for 3 phase better get the digital power meter for monitoring. It will be alot easier in wiring. Most of them should come with rs485 communication protocol to allow user to collect data..

    • @muhamadfaizalismail4280
      @muhamadfaizalismail4280 3 ปีที่แล้ว

      @@solarduino1374 can use it to measured 3 phase also right?

  • @josecarlossilva8404
    @josecarlossilva8404 3 ปีที่แล้ว +1

    congratulations on the video, the software provided by PZEM, can I change the slave address?

    • @solarduino1374
      @solarduino1374  3 ปีที่แล้ว

      Yes you can. If you have the programming cable (Serial USB port to RS485), PZEM software allows user to set address and shunt rating (for DC meter). You need to activate voltage measurement port in order to set the address.

    • @josecarlossilva8404
      @josecarlossilva8404 3 ปีที่แล้ว

      Ok, I Will buy PZEM dc and Ac monitoring using the PLC .
      Thank you Very much!

  • @TuanNguyen-jp3dh
    @TuanNguyen-jp3dh ปีที่แล้ว

    How can I use it with 2 sets of pzem-004T
    Please show me. Thank you

  • @sittiphanthiarachatanant3253
    @sittiphanthiarachatanant3253 3 ปีที่แล้ว

    2 dc meter, I set a address 0x02,why dont it changed?

  • @msTechOk
    @msTechOk 3 ปีที่แล้ว

    Can you share code combine 3 pzem 2 dc and 1 ac. I try copy code in this blog..but the meter pzem dc only one reading data meter?.thanks

  • @emvpthechannel2050
    @emvpthechannel2050 2 ปีที่แล้ว

    Can I use esp32 dev kit with this?

  • @giuseppecalasci3716
    @giuseppecalasci3716 ปีที่แล้ว

    Come faccio a cambiare indirizzo ?

  • @haitran3724
    @haitran3724 3 ปีที่แล้ว

    can i use 3 pzem 017?

    • @solarduino1374
      @solarduino1374  3 ปีที่แล้ว +1

      Technically it should work but you may need to modify the code quite abit especially to overcome the congested traffic to Blynk app

  • @dimasgandewa7375
    @dimasgandewa7375 3 ปีที่แล้ว +1

    2 ac code not working, please cek email, please help me🙏

  • @kusm4nLim
    @kusm4nLim ปีที่แล้ว

    I tried to install it and follow the instruction but I only can get one data meter either one or two. Please help me how to set the address step,, thanks

    • @solarduino1374
      @solarduino1374  ปีที่แล้ว

      Hi, it seems there are many people facing the same issue as the main problem is the addresses are not sussessfully set via the code (sometimes it may not work). In order to set the address with successfully, I suggest you to get the USB to rs485 cable and set it manually via pc software. After changed the address, it should work then.

    • @kusm4nLim
      @kusm4nLim ปีที่แล้ว

      @@solarduino1374 any reference can I follow?
      Thank you

    • @solarduino1374
      @solarduino1374  ปีที่แล้ว

      @@kusm4nLim hi, in my blog I have attached the software for the PZeM to change address, you just need to get the USB to rs485 cable

    • @kusm4nLim
      @kusm4nLim ปีที่แล้ว

      @@solarduino1374 ok Thanks
      I found same code may be miss type.
      On the line Blynk.virtualwrite(v5,Pzemvoltage) I think it would have 2 Pzemvoltage2.
      Correct me if I wrong.
      Thanks

    • @kusm4nLim
      @kusm4nLim ปีที่แล้ว

      @@solarduino1374 its working. After I reset the address again.
      Thank you very much

  • @haitran3724
    @haitran3724 3 ปีที่แล้ว

    2 X DC Energy Meter.ino NOT WORKING

    • @solarduino1374
      @solarduino1374  3 ปีที่แล้ว

      Most probably is address setting issue. Kindly double check the address. If you have serial USB RS485 cable, try set using manufacturer software..

    • @haitran3724
      @haitran3724 3 ปีที่แล้ว

      @@solarduino1374 I did as instructed in your blog. How to install them?

    • @haitran3724
      @haitran3724 3 ปีที่แล้ว

      @@solarduino1374 2 DC pzem they share the same address.
      For example
      Blynk.virtualWrite (V0, PZEMVoltage);
      Blynk.virtualWrite (V5, PZEMVoltage);
      They share a V0 address

    • @solarduino1374
      @solarduino1374  3 ปีที่แล้ว

      Kindly send your issues at solarduino.com@gmail.com...We can have private chat via email. Thanks