Steel Joist Design

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 พ.ย. 2024

ความคิดเห็น • 17

  • @jericpaguio19
    @jericpaguio19 ปีที่แล้ว

    Thank you Engr. currently 4th year CE student po ako, your videos are so helpful po.

  • @oellejoven1758
    @oellejoven1758 2 ปีที่แล้ว

    Thank Engr. for the very informative and added knowledge...God bless...

  • @harfeljayhiolen8950
    @harfeljayhiolen8950 ปีที่แล้ว +1

    Salamat engr

  • @joeannerebeto6256
    @joeannerebeto6256 ปีที่แล้ว

    hello po engineer naging popular na ngayun dito sa pinas ang cold formed steel using structure FrameCad software can analyzed the safety of whole structure? at naging popular at ginagamit na ng mga progressive country anu po sa tingin ninyu?

  • @habitnprofession6088
    @habitnprofession6088 5 หลายเดือนก่อน

    Sir dun po sa 4 meter span is okey lang kahit steel angle seat lang ang maging girder? meaning wala na po sa midspan.?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  5 หลายเดือนก่อน

      That's the most practical way of treating it. However, we need to calculate if steel angle would be capable. Thanks

  • @jephtisomosot9267
    @jephtisomosot9267 ปีที่แล้ว

    hello sir, same lang po ba strength ng GI at BI?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  ปีที่แล้ว

      GI could be made of mild steel ( structural grade min fy 276mpa), it is just treated to resist corrosion, while BI is a low carbon alloy steel and not recommended to use as structural material. Thanks

  • @DrongoDag
    @DrongoDag ปีที่แล้ว

    I wish there was an english subtitle

  • @juliusbriones7523
    @juliusbriones7523 2 ปีที่แล้ว

    Engr. good day, may binigay na design para sa renovation sa office ginamitan ng 1.3mmx50x150 c purlins ang lumabas sa apacing is 3meters lang kasi may intermediate beam sa 6mx6m grid span. at 1" or 25mm thk ficem board floor panel masyadong mabigat ang panel. ano sa tingin nyo engr. salamat po
    malaking tulong sa amin ang blog nyo sir. TY again

  • @mabinimanardas42
    @mabinimanardas42 ปีที่แล้ว

    sir can we use expanded bolt sa angle connections ?

  • @conradoyaranonjr2943
    @conradoyaranonjr2943 2 ปีที่แล้ว

    ..sr my tanung lng po ako kng anu tamang bakal na gagamitin sa buhos na na 2 story kng ilan bakal bawat poste kng ang sukat nya ay 5x9m...tama na ba ung 12mm sa poste...

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 ปีที่แล้ว +2

      Minimum sa poste 4-16mm, if you want 12mm you will need 8pcs. I think you can save money if you use 16mm Thanks

    • @conradoyaranonjr2943
      @conradoyaranonjr2943 2 ปีที่แล้ว

      @@jsdesign_engineeringtv3633 ..thanks po sa rply..sr ilan nman pong poste pg ganyan sukat kng 16mm ung gagamitin..

    • @harfeljayhiolen8950
      @harfeljayhiolen8950 ปีที่แล้ว

      ​@@conradoyaranonjr2943pwd 7