Well done sir, I had thought that what you explained was common sense until I became involved in a rebuilding project. The carpenter didn’t understand the superior strength of the 100 year old true dimensional hardwood joists, the contractor disputed the interior walls as supporting walls. I am showing them this lecture to support my positions, although today’s professionals only want to work with new materials.
During the pandemic there has been a significant increase in DIY'ers. So, your presentation is very much appreciated. I just had a brief discussion with a structural engineer this past week. I have since been researching more and more about forces on trusses and joists. All this is to help with an extension project and attic conversion in the future, after the supply chain issue and lumber prices hopefully will decline. Thank you. I also really appreciate the images and drawings. The more the merrier because visual presentations add so much more clarity and depth to any presentation, and yours was really important💯👍🇨🇦
@@BenGromicko Thank you. I have viewed a few more of your vids. The long one on inspecting cracks trusses was really informative. Keep up the good work. I will check out the link you sent. 👍🇨🇦😉
@@revolution6133 Here in Canada I am hoping that the Bank of Canada measures with their slow increase in interest rate hikes will somewhat curve the lumber prices amongst other pricing issues. Yes, patience is key. In the meantime I continue to save money, investing it in trading with solid companies that have a long history of increasing and sustaining their dividend. So, no rush because I get paid as I wait and keep reassessing the construction industry situation here in Atlantic Canada, East coast. Stay strong, keep safe.💯🇨🇦🍁
In our world there seems to be no end to rules and regulations, many which are based upon uneducated opinions and wild guesses that haven't had much thought put into them and are effectively useless. But when it comes to this subject, there is relatively precise data available from actual tests, so the results are predictable and can be measured. I wish all builders were aware of this. Start with your design needs, error toward the heavy side if unsure, and calculate what you need to achieve that. That's a much better approach than taking a wold guess and seeing how it turns out. And, it's always better to go a little heavier duty than needed to go a little cheaper and try to compensate some other way for marginal or sub-par performance. You never hear anyone say they wish their floor or roof wasn't so strong. Along this line, you might even find out that you can use a smaller framing member than your hunch and still meet the design goals.
@@G53X0Y0Z0 I have a very different opinion of codes versus requirements. People should not be building anything unless they know enough to use codes, but I think codes should be more like certifications rather than requirements. Requirements are often discriminatory and political whereas codes are just standards. For instance, bars/clubs have much less regulations to meet than churches (at least where I live). We saw this firsthand when bureaucrats decided which establishments were essential, closing outdoor dining of small restaurants while allowing massive gatherings of corporate establishments. Non-sensical (and anti-science) requirements were placed on stores that actually facilitated viral spread rather than reducing it, in the name of science of course. Many of these destructive and financially burdening requirements are still in place across the world. It was a perfect extreme to illustrate why requiring anything, even if the reasoning sounded good at first, is a violation of freedom which should never be allowed.
Good stuff: I really liked your explanation of joists wanting to lay flat in the middle of a span and how that ties in to blocking reduces deflection. I've always heard that blocking doesn't make a floor "stronger", while experience has taught me that midspan blocking makes it "better" Your video clarified my thinking on this. Thanks!
I've always heard that about blocking as well, but like you, I've always had a different opinion. It is just common sense that mid-span blocking will help distribute the load evenly across more of the joists at the point of maximum deflection.
What it doing is bracing against lateral torsional buckling. That’s what this “flopping” that he talked about is. Bracing the top flange by nailing the subfloor to it and bracing the bottom flange by nailing a drywall ceiling to it does the same thing.
Glad it was helpful! Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
WOW THANK YOU. I recently bought my first house and have been working on repairing the sag in the middle of the floor. I've been sistering a bunch of the joists with new wood and its taking me a lifetime due to the incredible amount of work. Also I wasn't sure if I was taking the best approach from an engineering stand point and this helps a lot. I'm going to to utilize these bridge blocks to significantly reduce the amount of work I will need to successfully complete my DIY job. Thanks again for this knowledge, it's very valuable to me
Solid bridging will strengthen a great deal as once tied together function as a whole unit…if over eight ft. in length install two rows I did it to my house and I have 2x8s that span a bit over 12 ft, …I put in two rows of blocking and it work very well…much cheaper then sistering especially these days…good luck…
Allowable deflection. I used to design I-joist floors in their beginning. Most people thought I-joists were designed to span super far, but the fact is, they were designed to be super predictable. I always designed floors to over perform, because most home owners expected better performance. Most home owners would be surprised to know, at the time, 9 1/2" I-joist DID NOT out perform 2x10s in a simple span. As a designer, I was always thankful that 'unacceptable deflection' was a long way from failure.
I hope this video gets watch by those in trades who believes mid span blocking is not really necessary. No, it is a MUST for a wood floor joists. In my own build i blocked every joist tight and glued. The difference before and after is incredible. It doesn’t only help to stiffen the floors but it reduces vibrations.
The number of blocks and the spacing of the blocks often overlooked. Too often people put a single row of blocks in the middle and call it good. A block every 4 feet along the length of joist is a cheap investment and a huge improvement in structural integrity and strength. Structural screws instead of nails are actually faster to install and are by far stiffer and stronger than nails as well. No such thing as too many blocks.
@@briangc1972 Totally agree from my experience. Material doesn’t cost much to blocking but it is a little labour intense if it is done right. To me blocks needs to be a tight fit and glued and screwed. If you are nailing a loose block you are asking for squeks as the joists deflect.
VERY WELL done! I didn’t learn much by way of practice (observation and mimicry have made sure all my DIY projects have been safe and compliant); but, now I understand WHY many requirements are what they are, and WHY certain practices seem ‘right’ and others seem ‘wrong’. In particular, I have a much better appreciation of the role of joist hangers and blocking. THANKS!
Plenty of comments from DIYers here. As a contractor and carpenter with 30 years experience, I’ll say this was excellent information. I’d caution DIYers, though, that building inspection, building science and actually building are very different things. Proper execution is critical, often overlooked and generally learned on the job. Also, the engineer I work with, who I’ve collaborated with on more than a dozen projects over 15 years, consults me of all the designs he does for me to see which is most practical in the field. He has enough humility to know that he doesn’t know more about building than I do, and over the years he has politely slapped me down enough times for me to realize I know less about structural work than I’d like to think. And a DIYer certainly knows less about both than either of us. So I think it’s great people doing their own work and I get the appeal, but keep in mind that often you don’t know what you don’t know and no amount of TH-cam can do much to change that. And if you don’t have permits, you don’t even have an inspector to keep you straight, the bare minimum really. My advice is to ingratiate yourself to a builder and see if you can get some paid consultation time. Again, you don’t know what you don’t know. I’ve made tens of thousands of dollars fixing work that homeowners did themselves.
Fair play that was extremely well presented and explained. I’m in the UK and, although, we have our own building regs, this made complete sense. Well done! 👍🙂🏴
floor decks people perceive to be "unacceptable" is really due to the deck weight per sq ft being "light". a "light" deck produces a lot of vibrations when people walk across the deck and describe this as "bouncing". if you would have placed 1-1/2" of of gypsum leveler on top of that same deck configuration, hence increasing its weight per sq ft, the deck would produce less vibrations and be perceived to perform better. vibration reduction is also done with blocking/ bridging along the joists, sheathing the underside of decks and perpendicular partitions to the floor joist direction. these items mostly dampen vibrations by connecting all the diaphragm/ floor elements together at more "points" to absorb vibrations induced by loads/ people walking- good video!!
I'm new to learning this and very eager... illustrations with each parts you're discussing will make it easier and avoid misunderstanding by newbies like me without engineering background. Tysm
I live in a 16' wide row home ( actually closer to 15' wide when you subtract the 10" poured concrete basement walls. While I was drilling 4 or 5 holes thru each basement joists noticed the two doubled up ones that provide extra support I guess for where stairwell is took a lot longer to drill my 3/4" diameter holes. While pulling wire noticed the doubled up joust were 3 by 12 and a different guess stronger species of wood. Bet contractors have not did this use in many years. While an electrical apprentice we were taught to avoid the middle third of all joists whenever possible. Also believed it was better to drill two 3/4" holes at least two inches apart then a big 1.25" hole for wires.
I used 2x 6x 30' iron C purlin. I welded back to back to make into an "I " beam. For my Floor joists. No squeeking here. I put the 3/4 inch plywood across two sections to see deflection in floor then I spaced out I beams until no floor deflection. I also put another 1/2" plywood glued to 3/4" layer opposite direction. Very very strong floor.
My house was built in 1935. Over the living room are 6x8 joists (exposed, no blocking). True measurements are 5-1/2 x 7-1/4. They are on 32” centers, 15 foot spans. Walls are concrete block with open cells. I don’t know how much they bear. The first joist is on the edge of the stairwell and has the bedroom wall sitting on it, it is visibly deflected or curved downwards and has cracks along roughly the middle sides. The rest of the joists look good, straight, no cracks. The sub floor above is 1x12 knotty pine panelling with Douglas fir floor on top.
Very good informative video. Try to find a span table for your jurisdiction and you will find that the allowable span increases with the addition of solid blocking, cross bridging, cross bridging with strapping under the joist and also with construction adhesive with the subfloor. I believe in our area the max span for 2x10 ss spf on 16" oc is 16' 1" with 2 rows of crossbridging with strapping and glued 5/8" subfloor as opposed to about 13' 5' with just subfloor and one row of strapping which is the bare minimum.
My od carpenter rule of thumb, when using softwood framing lumber, was to divide the span, and, add 2, so for a 16 foot span, you would use a 2x10 for a normal load. Using structural fir, makes them stiffer, or switching from 16inch spacing to 12 inch spacing also increases strength, Adding blocking between joists stiffens floors because is limits deflection. Now we use a lot of structural lumber, or engineered floor systems, here we generally rely on the reccomendations of the supplier.
Hi Keith. Here in Canada our code will allow a 2x10 to span approximately 13'-8" to 14' depending on bringing and strapping. 2x12's are 15'-6" or slightly better. These are @ 16" o.c.. it was an interesting talk.
@@warrenshalm550 I live in estreme north east Minnesota, our county does not enforce a building code on resedential structures. Most licensed contractors do use the national codes. Your spans sound about what I have used, of course if you specify structural grade fir, as opposed to just softwood lumber, you will get much stiffer floors. As I said, using 12 on centers will also allow for longer spans with a given joist. Also using bridging to avoid deflection also helps. Most of our floors are now down with TJI's or some other floor truss system. The TJI's are lighter, have knock outs for electrical and plumbing, and, can be ordered in long lenghts, so even if you use a center beam or wall you can use a continuous joist, we can get them up to 32 feet in lenght. They have also replaced solid wood rafters in a lot of roof framing.
You're absolutely correct Keith. The betyer grades of lumber have greater spans and of course engineered lumbere has become popular for reasons you state. What has driven the choice in the last year for us has been availability shortages. That is in everything related to construction.
Thanks. Folks should know that a structural engineer can analyze issues for little money. I opened a ceiling and found one 2x4 holding a roof load. I knew I could use a simple 4x6 beam but couldn’t contact the clients to approve the design change. I went to a local structural engineer. He quickly entered the data of the existing structure in that area into his computer program. I was able to use three select structural 2x4’s laminated together and keep them hidden above the ceiling drywall. $200 well spent!
I learned more information, useful information, here than any other video designed to easily propogate as an ad-hoc, overly generalized, and otherwise useless answer my question. At least now I know how to mitigate my problem.
I built a "pit" for servicing my trucks and searched for guidelines for the beams I used. I couldn't find anything that applied to what I was building so I erred on the side of safety. The pit was constructed outside between my deck and my garage so I don't have to worry about air quality like pits built in a garage floor. I started by building a 10 x 10 concrete pad with two sections of concrete filled block pillars 8" x 32" at the end (actually, these pillars are part of a concrete filled concrete block wall, so the pillars are effectively 16 x 32 also). Then 4 concrete filled concrete block pillars 16" x 32". I spanned the pillars with 2-2x12's and 4 2x10's to create each "beam" with added blocking and 2x10's for decking. The beams are about 14' long, supported by the 3 pillars on each side. My trucks weigh around 9500 lbs. and I was real nervous when I tested it the first time. I set up a tape measure at the middle of the longest span and was unable to detect any deflection whatsoever. Obviously I over engineered my project, but at least I know that I can change the oil in a semi without having to rebuild it bigger.
Deck boards presumably contribute significantly to mimising joist rotation. Is this element factored into deck framing when determining joist spans, blocking requirements, joists thickness etc?
Zero chance a 3x10 will span 20' safely or without insane deflection. Sistered 2x10s would be better, but you should honestly be looking at sisters 2x12s or larger. It gets to the point where you should be using engineering beams, LVLs or engineered members.
Quick question. I have a fifty by fifty gym in the basement which is in planning stages. Is there a way to construct this without poles for support. I wanted to keep it as one large open air gym but I don’t know how to support the floor above. Any thoughts? Thanks
Nice video but need to explain how many feet a 12' 20', etc, joist can span without deflection. How close can you put the joists together to help witt deflection. How wide joists need to be to withstand deflection for 12' , 20' 25' etc. How much weight can a most common pine wood 2×4, 2x6, 2x10, 2x12, etc. Hold before deflection. Is there a right direction to put in the joist based on the grain?
does r301.7 apply to roof joists on a flat style roof ? I recently observed 5/8 inch deflection on a 20 foot span with 10.5 inch wide joists on 24 inch centers when the roof was loaded with a 1500 lb. piece of equipment in the center of the span. the center area had blocking added to help spread the load out over a larger area in the roof structure . This "dead load " would be added to the capacity of the roof when supporting snow and rain in winter .
Thank you for putting this together Ben. I’m in the process of building a torsion box for a CNC table, and your presentation helped me with a few terms and concepts. :)
I am currently restoring (not rebuilding) a home that is about 100 years old. They used 2x6s and 2x8 for the floor joists. Many have cracked on the sill plates. I am keeping with the same pattern but replacing joists of the same size using joist hangers, structural bolts for sistering, blocking, and post supports. it is a small house, 1300 sqft, so without over-engineering things, I think updated lumber and structural support should be enough to keep this house sitting for much longer. It is also grandfathered into our local building codes so I do not need to perform intense structural changes or have them inspected to modern codes.
A old school builder taught me years ago about spans. Get your length and half it and plus one is the best I’ve ever heard. So on a 20 ft Span half it plus one and it’s a 11 inch timber
If you want to increase the load bearing capabilities of your joists without too much of an additional expense, fasten a steel strap to the bottom of each joist (it can be every other joist depending on your load bearing requirements for the floor). Steel strapping comes in 25 foot lengths up to 16 gage with lots of holes the entire length. Use 2 to 3 inch deck screws every 4 to 6 inches. The result is that all "tension" is moved to the bottom of the joist with the "neutral plane at (or near) the bottom of the joist, leaving all of the joist as the "compression area". "Deflection" will be greatly reduced compared to a joist without the steel strap. "Weight bearing" capability will probably be at least double that of a joist without the steel straps. A good idea is to extend the ends of the strap around the ends of each joist a couple of inches and fasten with two deck screws. I use this idea on fence posts that always eventually rot right at ground level to keep them from being knocked over too easily!
@@jamesrussell6870 Thanks! I didn't know it was called "load sharing bridging". I've never seen this done by anyone else, and for me it was just solving a problem using basic physics. I'm a DIY handyman type with no formal training in construction.
If you an at the load limit of a joist, and change the centers to 12 inch centers and glue and screw the sub floor would it be as good as if you used wider joists on standard centers?
I clicked the video thinking to get some guidelines about what size joists and what spacing to use in what situations, which I'll have to look into further... But it did make me thinking about the blocking: If putting blocking halfway the span prevents the joist to flop over, effectively halving the span over which the joist can twist, does halving the span again by adding blocking every quarter of the span add much stiffness to the construction, or are the gains compared to just one row of blocking in the middle negligible? We're talking about a span of 175" which will be realized with 3" x 9" joists (can't go higher because of ceiling height). I'm thinking about placing them 19.2" on center with 1 or if useful 3 rows of blocking. I could do 16" on center, but I prefer not to as the beams will stay visible from below and more beams closer together would result in a busier looking ceiling, even without blocking...
What was the load per square foot regulations for floors back in the early 1900s? I know currently it’s 40lbs per square foot, my house was built in ‘26 and I was wondering if it would be safe to put a 670 pound safe upstairs?
When doing my new home construction, my builder stated a span of 14 ft. was too wide to use the standard LVL's. My homework revealed the possibility of using a Flitch beam. Instead of ordering it from Australia, I made one in my garage. You might consider looking this up, if you run into the same issue.
Thanks for this video. I was worried that the floor spans in my Minecraft castle might be too long, but this helped me to understand why some of the historical floor plans I've seen had >10 m wide rooms with wooden floors -- medieval contractors probably didn't care about floor sag as much as we do today (and trusses probably helped too). Now I can build my 10 m wide wood floors without worrying about historical accuracy. I'll just have to remember not to put all my chests in the middle of the room.
i can't find resources to explain the charts. trying to design 2nd floor. post frame 8' apart columns 2x8" 3 ply. 20'x40. put leger board into columns baloon frame style at the gable end and in the middle of floating slab add pier columns for the opposite side leger board. I can add up the lbs going onto each column but I don't understand how to read the LVL charts.
So if my calculations are correct, using L/360 when using 12’, 2x6 lumber for a shed floor joist means it is acceptable that the 2x6 bow a maximum of 0.4 inches? I’m currently using 3, 2x6 joists 16” on center spanning 12 feet. I did do blocking. The center joist is currently bowed 1/4” and I’m not done adding all the totes with seasonal items on the loft. I’m thinking about sistering at least the center joist. Thoughts?
Very interesting and above all informative .. tone, voice and content are perfect … just wish you were able to provide us with drawings or pictures for each case it makes it way easier for your audience to understand faster or make sure we have the same idea in mind … I’m nonetheless very grateful for the great explanation you granted us with in this video!
I am a visual person so I have to see it so having a pictures or drawings illustrations that would be perfect that would be nice if could do part 2 with images would be amazing. Just a thought. Thank you so much.
One point I would like to add from the real world is the effect of knots in joists. During an inspection, I saw a garage ceiling with 2 x 8 joists. Three consecutive joists had a knot in the bottom edge about three inches deep. They had deflected about two inches and were starting to crack along their length from the top of the knot. I would say that the framer should have been hung from those joists for using those particular pieces, but he'd probably escape unharmed.
Great information, I have a 1950s single story with water damaged floor and floor joist. They're 2x8s could I replace them with 2x10 with a notch cut out on the outer bottom edge?
I wouldn't do it. That notch in the bottom creates a perfect place for a split to start as well as making the extra two inches useless. Find a way to lower the support base or use 2 x 8s
@@stratocruising i looked underneath and the floor joist have sunken in at the end on the outer foundation. Its at most 1/8 to 1/4 in. can a shim work underneath there or would the joist need to be sistered?
@@luisfigueroa7851 Not exactly sure what has deformed; has the outer foundation (Wood, I assume) collapsed slightly or is the floor joist now smaller than 2" x 8' at the end? if it is the first, a shim would work, but make it broader than the joist bearing on it to spread the load out over a larger surface. If it is the later, I'd sister it for the first 2-3 feet
@@stratocruising thank you, I think its the first where the wood that rest on the foundation (in my situation) has settled or got squished over time. Ill make my plan of act soon. Again thank you for the information.
Can anyone give an answer, making a horizontal roof with 5 x 30 cm wood joists (30 cm being vertically) would the joists in 5 meters length bend from it's own weight and snow ? And what is the max spacing required between joists, is 70 cm enough ?
i understand this question is for my structural engineer but wanted to see if you would have an answer. we have a 32 feet wide 130 feet long structure.. the floor would be hollow core precast slabs. what would be the size of the columns and beam to hold the weight of each precast slabs without any support in between 32 feet width?
We have a newer home less then 2 years old with 2x10 floor joists and I noticed that one of the joists has a horizontal crack about 18 inches long on one end of the joist that rests on an LVL beam. This crack is in the middle area of the joist width as you indicated in the video and is about 1/16 of an inch wide. There is nothing significantly heavy sitting over the area in the floor above the joist. Is this any kind of concern?
No, it will not fail. Easy to repair if there are no wires or pipes going thru that section. Just sister some 2x10 or 3/4” plywood on both sides. Construction glue and nails.
If sistering is not possible get some large mending plates and hammer them on the cracks. I would squeeze some construction adhesive inside the crack before doing this.
Unfortunately there is a lot of wiring that passes through the joist so that would require pulling all the wiring from the panel. I will monitor it for now as it has not changed in size or diameter.
@@p51mustang31 Cut 3/4" plywood as if there were no wires, then drill for the wires and cut the patch to split it at the wires. The glue and screw it in place. Do that to both sides.
What I see a LOT in houses I've worked on for restoration is holes for wiring and plumbing being drilled far too close to the tension portion of a joist, sometimes even notches cut right out of the bottom. Not only is this annoying because when cutting through or tearing down ceiling drywall you have a high risk of damaging electrical and plumbing (not to mention people who do that never put up nail guards), but it effectively reduces the strength of each joist by how much was cut or drilled out. What's more, if someone else goes in and drills additional holes in at the proper distance, now they're cutting though the new tension point that the first person created, further reducing the load the joist can handle.
Hi, i live in Mass, and I want a marble fireplace the guy who selling it says its about 600 lbs I live on the 3rd floor the room is 384 square feet. It's about 20 feet long and 12 feet wide. Would it be safe to have? I am not good in math and don't know anything about the subject. I'd appreciate any help
I just did some 2x10 blocking in my basement area for the living room above, that is always bouncing when the kids play. Some of the blocks fit ok and some are a little tight/loose. I used long general purpose wood screws. Floor seems more stable, but when I walk into the living room in the morning I hear a few loud cracks/pops. Seems like it's only once or twice a day. It's not my subfloor since I screwed the plywood down before laying 3/4" hardwood a year ago. What's this popping noise and should I be concerned? This is only a 21" section I blocked. My span is 14' and the house is 32 years old. Home was built with the 1x3 diagonal bracing, but that stuff wasn't helping it seems.
The popping sound is the loose fit of the blocking. Since you screwed in the blocks, remove the loose ones and replace with tighter fitting blocks. Add more blocking every 4' along the length of the joists and cut them to fit less loose. One row of blocking in the middle is not adequate.
Related to notches in the ends of joists. I remember reading something that claimed that strength of the joist is more complicated than simply the depth at the ends, i.e. that if you have a 2x12 joist and you cut 2" x 2" out of the bottom corner on each end, the joist is not reduced to effectively a 2x10 joist, that it's still stronger than a plain 2x10. Is that true?
Best joist would be a steel plate sandwiched between timber. Any timber joist in a house would be bouncy one way or another, prone to horizontal cracks in the middle over 30-50 years, unless it's the size of a tree trunk. Builders make houses just enough to coope with the regs, calculations are 'just enough', no space for 'just in case' load would be 100-200kg more. Omnishambles. Steel frames for structure and glass and wood for decor ought to be the future.
the home inspectors im my area will do a slow drive by and look at the framing inbetween swigs of old grand dad and give a thumbs up. Its ok because the “framers” here from south of the border have no carpentry education at all. The city here will approve anything since they arent responsible for problems and the builders go in and out of business yearly. Very shoddy work in the south.
wow...in simple terms....thanks...this video was just what I needed...all my beams are solid teak and I was worried about the span I am building....not anymore!
Great information and well explained, and you hit many important points. However, I learn best with diagrams and photos. If you revise this video, please add a diagram or photo for each point you make. If that were the case, this would be a KILLER video!
I wonder if joist flop over is similar to when I was a little kid and decided to do a tight rope walk on the edge of the cat's litter box. I balanced myself so the plastic edge of the litter box was supporting my weight, but it tipped over at mid-point. I think it's because the plastic started to buckle causing a twist in my applied weight. There was a solid support for my weight at the box corner but when I got mid-point something like torsion was created. Of course, my mom was not happy about me using the cat box for stress testing.
So how far can my double lvl span?? (1 3/4x7 1/4).. addition to my garage 30x30. Using these lvls cause I have 5 million tgi’s in my garage. I’m doing a triple 2x10 in center, piers 7.5’ so 5 piers in center. On my gable side is my steel which I know is good. The overframe side that lands on my existing garage roof is where I’m putting these lvls. 8’ away.
This is simply an EXCELLENT summary for the layman, who is not a structural engineer. Thanks so much!
Glad it was helpful!
Simple, clear and well structured.
Each relevant section is presented and can thus be further researched. Thank you.
Thanks, Alex.
Well done sir, I had thought that what you explained was common sense until I became involved in a rebuilding project. The carpenter didn’t understand the superior strength of the 100 year old true dimensional hardwood joists, the contractor disputed the interior walls as supporting walls. I am showing them this lecture to support my positions, although today’s professionals only want to work with new materials.
If the joists are bearing on the interior walls, then they are “supporting walls”.
Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
@@mikewilson9349duh
During the pandemic there has been a significant increase in DIY'ers. So, your presentation is very much appreciated. I just had a brief discussion with a structural engineer this past week. I have since been researching more and more about forces on trusses and joists. All this is to help with an extension project and attic conversion in the future, after the supply chain issue and lumber prices hopefully will decline. Thank you. I also really appreciate the images and drawings. The more the merrier because visual presentations add so much more clarity and depth to any presentation, and yours was really important💯👍🇨🇦
Thanks for watching the video. The information about spans comes from Glenn at buildingcodecollege.com/.
@@BenGromicko Thank you. I have viewed a few more of your vids. The long one on inspecting cracks trusses was really informative. Keep up the good work. I will check out the link you sent. 👍🇨🇦😉
Lumber prices won’t be going down for a long time. Local lumber prices are going up every week!
@@revolution6133 Here in Canada I am hoping that the Bank of Canada measures with their slow increase in interest rate hikes will somewhat curve the lumber prices amongst other pricing issues. Yes, patience is key. In the meantime I continue to save money, investing it in trading with solid companies that have a long history of increasing and sustaining their dividend. So, no rush because I get paid as I wait and keep reassessing the construction industry situation here in Atlantic Canada, East coast. Stay strong, keep safe.💯🇨🇦🍁
Speaking with Engineer’s is always good also research the Building Codes of your state Chapter 25 gives you basic Span charts for Rafters and joists.
As an engineer, I think codes are really cool. They take a lot of research and experience and produce simple guides.
So true, and yet, people dread and fear codes.
Thanks, Austin. I agree with you.
In our world there seems to be no end to rules and regulations, many which are based upon uneducated opinions and wild guesses that haven't had much thought put into them and are effectively useless. But when it comes to this subject, there is relatively precise data available from actual tests, so the results are predictable and can be measured. I wish all builders were aware of this. Start with your design needs, error toward the heavy side if unsure, and calculate what you need to achieve that. That's a much better approach than taking a wold guess and seeing how it turns out. And, it's always better to go a little heavier duty than needed to go a little cheaper and try to compensate some other way for marginal or sub-par performance. You never hear anyone say they wish their floor or roof wasn't so strong. Along this line, you might even find out that you can use a smaller framing member than your hunch and still meet the design goals.
@@G53X0Y0Z0
I have a very different opinion of codes versus requirements. People should not be building anything unless they know enough to use codes, but I think codes should be more like certifications rather than requirements. Requirements are often discriminatory and political whereas codes are just standards.
For instance, bars/clubs have much less regulations to meet than churches (at least where I live). We saw this firsthand when bureaucrats decided which establishments were essential, closing outdoor dining of small restaurants while allowing massive gatherings of corporate establishments. Non-sensical (and anti-science) requirements were placed on stores that actually facilitated viral spread rather than reducing it, in the name of science of course. Many of these destructive and financially burdening requirements are still in place across the world. It was a perfect extreme to illustrate why requiring anything, even if the reasoning sounded good at first, is a violation of freedom which should never be allowed.
@@Austin1990 wrong soapbox.
Good stuff: I really liked your explanation of joists wanting to lay flat in the middle of a span and how that ties in to blocking reduces deflection. I've always heard that blocking doesn't make a floor "stronger", while experience has taught me that midspan blocking makes it "better" Your video clarified my thinking on this. Thanks!
I've always heard that about blocking as well, but like you, I've always had a different opinion. It is just common sense that mid-span blocking will help distribute the load evenly across more of the joists at the point of maximum deflection.
What it doing is bracing against lateral torsional buckling. That’s what this “flopping” that he talked about is. Bracing the top flange by nailing the subfloor to it and bracing the bottom flange by nailing a drywall ceiling to it does the same thing.
Glad it was helpful! Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
WOW THANK YOU. I recently bought my first house and have been working on repairing the sag in the middle of the floor. I've been sistering a bunch of the joists with new wood and its taking me a lifetime due to the incredible amount of work. Also I wasn't sure if I was taking the best approach from an engineering stand point and this helps a lot. I'm going to to utilize these bridge blocks to significantly reduce the amount of work I will need to successfully complete my DIY job. Thanks again for this knowledge, it's very valuable to me
Solid bridging will strengthen a great deal as once tied together function as a whole unit…if over eight ft. in length install two rows I did it to my house and I have 2x8s that span a bit over 12 ft, …I put in two rows of blocking and it work very well…much cheaper then sistering especially these days…good luck…
Thank for watching.
Excellent delivery of the information. Thank you.
Thank you, Mike.
Allowable deflection. I used to design I-joist floors in their beginning. Most people thought I-joists were designed to span super far, but the fact is, they were designed to be super predictable. I always designed floors to over perform, because most home owners expected better performance. Most home owners would be surprised to know, at the time, 9 1/2" I-joist DID NOT out perform 2x10s in a simple span. As a designer, I was always thankful that 'unacceptable deflection' was a long way from failure.
Good comment. Thank you for watching. And I love your brother's movie.
Straight forward to the point. No stupid commentary. Also, the formulas are a plus. 👍
Thank you.
So much info jam packed in this video. Gonna have to throw it on repeat. Great work!
Awesome, thank you! Thanks for watching the video. The information about spans comes from Glenn at buildingcodecollege.com/.
Interesting information. I learned a few things today. Thank you for taking the time to share and teach.
Glad it was helpful! Thanks for watching the video. The information about spans comes from Glenn at buildingcodecollege.com/.
I hope this video gets watch by those in trades who believes mid span blocking is not really necessary. No, it is a MUST for a wood floor joists. In my own build i blocked every joist tight and glued. The difference before and after is incredible. It doesn’t only help to stiffen the floors but it reduces vibrations.
Thank you for watching. That information is from Glenn Mathewson from buildingcodecollege.com/. Check him out.
The number of blocks and the spacing of the blocks often overlooked. Too often people put a single row of blocks in the middle and call it good. A block every 4 feet along the length of joist is a cheap investment and a huge improvement in structural integrity and strength. Structural screws instead of nails are actually faster to install and are by far stiffer and stronger than nails as well. No such thing as too many blocks.
@@briangc1972 Totally agree from my experience. Material doesn’t cost much to blocking but it is a little labour intense if it is done right. To me blocks needs to be a tight fit and glued and screwed. If you are nailing a loose block you are asking for squeks as the joists deflect.
VERY WELL done! I didn’t learn much by way of practice (observation and mimicry have made sure all my DIY projects have been safe and compliant); but, now I understand WHY many requirements are what they are, and WHY certain practices seem ‘right’ and others seem ‘wrong’. In particular, I have a much better appreciation of the role of joist hangers and blocking. THANKS!
Thank you! Cheers! That information is from Glenn Mathewson from buildingcodecollege.com/. Check him out.
Plenty of comments from DIYers here. As a contractor and carpenter with 30 years experience, I’ll say this was excellent information. I’d caution DIYers, though, that building inspection, building science and actually building are very different things. Proper execution is critical, often overlooked and generally learned on the job. Also, the engineer I work with, who I’ve collaborated with on more than a dozen projects over 15 years, consults me of all the designs he does for me to see which is most practical in the field. He has enough humility to know that he doesn’t know more about building than I do, and over the years he has politely slapped me down enough times for me to realize I know less about structural work than I’d like to think. And a DIYer certainly knows less about both than either of us. So I think it’s great people doing their own work and I get the appeal, but keep in mind that often you don’t know what you don’t know and no amount of TH-cam can do much to change that. And if you don’t have permits, you don’t even have an inspector to keep you straight, the bare minimum really. My advice is to ingratiate yourself to a builder and see if you can get some paid consultation time. Again, you don’t know what you don’t know. I’ve made tens of thousands of dollars fixing work that homeowners did themselves.
Glad you enjoyed watching the video.
Fair play that was extremely well presented and explained. I’m in the UK and, although, we have our own building regs, this made complete sense. Well done! 👍🙂🏴
Thank you. I love the UK. Can't wait to come back and visit.
Excellent assemblage of information and great presentation. I enjoyed watching it.
Thank you, Steevo.
Ben you did a great job explaining that hidden life of a joist...thanks dude
Glad it was helpful! Thanks for watching the video. The information about spans comes from Glenn at buildingcodecollege.com/.
floor decks people perceive to be "unacceptable" is really due to the deck weight per sq ft being "light". a "light" deck produces a lot of vibrations when people walk across the deck and describe this as "bouncing". if you would have placed 1-1/2" of of gypsum leveler on top of that same deck configuration, hence increasing its weight per sq ft, the deck would produce less vibrations and be perceived to perform better. vibration reduction is also done with blocking/ bridging along the joists, sheathing the underside of decks and perpendicular partitions to the floor joist direction. these items mostly dampen vibrations by connecting all the diaphragm/ floor elements together at more "points" to absorb vibrations induced by loads/ people walking- good video!!
Bingo !
Thanks for watching and commenting, Brett.
I'm new to learning this and very eager... illustrations with each parts you're discussing will make it easier and avoid misunderstanding by newbies like me without engineering background. Tysm
I agree. We’ll do that for the next video.
I live in a 16' wide row home ( actually closer to 15' wide when you subtract the 10" poured concrete basement walls. While I was drilling 4 or 5 holes thru each basement joists noticed the two doubled up ones that provide extra support I guess for where stairwell is took a lot longer to drill my 3/4" diameter holes. While pulling wire noticed the doubled up joust were 3 by 12 and a different guess stronger species of wood. Bet contractors have not did this use in many years. While an electrical apprentice we were taught to avoid the middle third of all joists whenever possible. Also believed it was better to drill two 3/4" holes at least two inches apart then a big 1.25" hole for wires.
Thanks for watching.
I used 2x 6x 30' iron C purlin. I welded back to back to make into an "I " beam. For my
Floor joists. No squeeking here. I put the 3/4 inch plywood across two sections to see deflection in floor then I spaced out I beams until no floor deflection. I also put another 1/2" plywood glued to 3/4" layer opposite direction.
Very very strong floor.
Nice.
So your floor is 1 1/4" ?
What did you use for adhesive?
My house was built in 1935. Over the living room are 6x8 joists (exposed, no blocking). True measurements are 5-1/2 x 7-1/4. They are on 32” centers, 15 foot spans. Walls are concrete block with open cells. I don’t know how much they bear. The first joist is on the edge of the stairwell and has the bedroom wall sitting on it, it is visibly deflected or curved downwards and has cracks along roughly the middle sides. The rest of the joists look good, straight, no cracks. The sub floor above is 1x12 knotty pine panelling with Douglas fir floor on top.
Good to hear, David. Thanks for watching.
So good, rebuilding a deck inside a warehouse, you put all my worries to rest. Thank you
Thank you for watching.
I have so much appreciation for this presentation I love this practical application of science!
Glad it was helpful!
This is the side of TH-cam for men, fathers, and builders of America.
Thanks for watching.
Very good informative video. Try to find a span table for your jurisdiction and you will find that the allowable span increases with the addition of solid blocking, cross bridging, cross bridging with strapping under the joist and also with construction adhesive with the subfloor. I believe in our area the max span for 2x10 ss spf on 16" oc is 16' 1" with 2 rows of crossbridging with strapping and glued 5/8" subfloor as opposed to about 13' 5' with just subfloor and one row of strapping which is the bare minimum.
Thank you.
What direction of grain resists deflection best? Flat (plain) sawn or quarter sawn?
@@grounded7362 good question.
Thanks for making the video. Certainly helped to understand the basics, now i can learn more.
Glad it was helpful!
This is a great video. No nonsense and very well explained.
Thank you very much 👍
Glad it was helpful! The content was provided by Glenn at buildingcodecollege.com/.
My od carpenter rule of thumb, when using softwood framing lumber, was to divide the span, and, add 2, so for a 16 foot span, you would use a 2x10 for a normal load. Using structural fir, makes them stiffer, or switching from 16inch spacing to 12 inch spacing also increases strength, Adding blocking between joists stiffens floors because is limits deflection. Now we use a lot of structural lumber, or engineered floor systems, here we generally rely on the reccomendations of the supplier.
That's great stuff, Keith. Thank you for sharing.
Hi Keith. Here in Canada our code will allow a 2x10 to span approximately 13'-8" to 14' depending on bringing and strapping. 2x12's are 15'-6" or slightly better. These are @ 16" o.c.. it was an interesting talk.
@@warrenshalm550 I live in estreme north east Minnesota, our county does not enforce a building code on resedential structures. Most licensed contractors do use the national codes. Your spans sound about what I have used, of course if you specify structural grade fir, as opposed to just softwood lumber, you will get much stiffer floors. As I said, using 12 on centers will also allow for longer spans with a given joist. Also using bridging to avoid deflection also helps. Most of our floors are now down with TJI's or some other floor truss system. The TJI's are lighter, have knock outs for electrical and plumbing, and, can be ordered in long lenghts, so even if you use a center beam or wall you can use a continuous joist, we can get them up to 32 feet in lenght. They have also replaced solid wood rafters in a lot of roof framing.
You're absolutely correct Keith. The betyer grades of lumber have greater spans and of course engineered lumbere has become popular for reasons you state. What has driven the choice in the last year for us has been availability shortages. That is in everything related to construction.
Thanks. Folks should know that a structural engineer can analyze issues for little money. I opened a ceiling and found one 2x4 holding a roof load. I knew I could use a simple 4x6 beam but couldn’t contact the clients to approve the design change. I went to a local structural engineer. He quickly entered the data of the existing structure in that area into his computer program. I was able to use three select structural 2x4’s laminated together and keep them hidden above the ceiling drywall. $200 well spent!
Thank you for watching our videos and commenting here.
Your explanations are excellent. Thank you!
Glad you like them!
I learned more information, useful information, here than any other video designed to easily propogate as an ad-hoc, overly generalized, and otherwise useless answer my question. At least now I know how to mitigate my problem.
Thanks for watching.
Well explained, visual aids, photos, etc, would also help tremendously.
Thanks for watching the video. The information about spans comes from Glenn at buildingcodecollege.com/.
Thankyou for the help you've given in this presentation . . . Chris . . . Norwich, England
Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
I built a "pit" for servicing my trucks and searched for guidelines for the beams I used. I couldn't find anything that applied to what I was building so I erred on the side of safety. The pit was constructed outside between my deck and my garage so I don't have to worry about air quality like pits built in a garage floor. I started by building a 10 x 10 concrete pad with two sections of concrete filled block pillars 8" x 32" at the end (actually, these pillars are part of a concrete filled concrete block wall, so the pillars are effectively 16 x 32 also). Then 4 concrete filled concrete block pillars 16" x 32". I spanned the pillars with 2-2x12's and 4 2x10's to create each "beam" with added blocking and 2x10's for decking. The beams are about 14' long, supported by the 3 pillars on each side. My trucks weigh around 9500 lbs. and I was real nervous when I tested it the first time. I set up a tape measure at the middle of the longest span and was unable to detect any deflection whatsoever. Obviously I over engineered my project, but at least I know that I can change the oil in a semi without having to rebuild it bigger.
Great information and feedback, Hot Shot Truckin'. Thanks for watching and sharing that information.
Fantastic video! Clear and concise.
Glad it was helpful!
One of the better explanations I've watched
Thanks.
Thank you very much. This all makes sense to me now. My attic build will be better for it. Cheers
Great to hear! That info comes from Glenn Mathewson of buildingcodecollege.com/.
Deck boards presumably contribute significantly to mimising joist rotation. Is this element factored into deck framing when determining joist spans, blocking requirements, joists thickness etc?
Good question. Yes. Thanks for watching.
Can a 3x10 custom milled fir span 20'? Or two sistered 2x10's?
@@manfrummt good question.
Zero chance a 3x10 will span 20' safely or without insane deflection. Sistered 2x10s would be better, but you should honestly be looking at sisters 2x12s or larger. It gets to the point where you should be using engineering beams, LVLs or engineered members.
Quick question. I have a fifty by fifty gym in the basement which is in planning stages. Is there a way to construct this without poles for support. I wanted to keep it as one large open air gym but I don’t know how to support the floor above. Any thoughts? Thanks
Great question for your local licensed GC.
Lots of good info here! I'm building my own barndominium and I'm at the joist stage. I appreciate it
You're welcome.
Nice video but need to explain how many feet a 12' 20', etc, joist can span without deflection.
How close can you put the joists together to help witt deflection. How wide joists need to be to withstand deflection for 12' , 20' 25' etc. How much weight can a most common pine wood 2×4, 2x6, 2x10, 2x12, etc. Hold before deflection. Is there a right direction to put in the joist based on the grain?
Thanks for watching.
does r301.7 apply to roof joists on a flat style roof ? I recently observed 5/8 inch deflection on a 20 foot span with 10.5 inch wide joists on 24 inch centers when the roof was loaded with a 1500 lb. piece of equipment in the center of the span. the center area had blocking added to help spread the load out over a larger area in the roof structure . This "dead load " would be added to the capacity of the roof when supporting snow and rain in winter .
Thanks for watching.
Thank you for putting this together Ben. I’m in the process of building a torsion box for a CNC table, and your presentation helped me with a few terms and concepts. :)
Glad it was helpful!
douglas
What's a torsion box?
And what does that CNC machine do?
We have a small Woodwork factory.
I am currently restoring (not rebuilding) a home that is about 100 years old. They used 2x6s and 2x8 for the floor joists. Many have cracked on the sill plates. I am keeping with the same pattern but replacing joists of the same size using joist hangers, structural bolts for sistering, blocking, and post supports. it is a small house, 1300 sqft, so without over-engineering things, I think updated lumber and structural support should be enough to keep this house sitting for much longer. It is also grandfathered into our local building codes so I do not need to perform intense structural changes or have them inspected to modern codes.
Thanks for watching, Michael. And for commenting.
A old school builder taught me years ago about spans.
Get your length and half it and plus one is the best I’ve ever heard.
So on a 20 ft Span half it plus one and it’s a 11 inch timber
That's a great tip. I like it.
Well, I’m glad someone else out there is advocating for a minimum of L/360 TL deflection!
Yep. That info comes from Glenn Mathewson of buildingcodecollege.com/ who wrote that content.
@6:40 marker about "greater the 212"... what does that mean explained? Width×Highth ..ratio maybe?
Hm. I'll take a closer look.
Please explain height vs width greater than 212.
If you want to increase the load bearing capabilities of your joists without too much of an additional expense, fasten a steel strap to the bottom of each joist (it can be every other joist depending on your load bearing requirements for the floor). Steel strapping comes in 25 foot lengths up to 16 gage with lots of holes the entire length. Use 2 to 3 inch deck screws every 4 to 6 inches. The result is that all "tension" is moved to the bottom of the joist with the "neutral plane at (or near) the bottom of the joist, leaving all of the joist as the "compression area". "Deflection" will be greatly reduced compared to a joist without the steel strap. "Weight bearing" capability will probably be at least double that of a joist without the steel straps. A good idea is to extend the ends of the strap around the ends of each joist a couple of inches and fasten with two deck screws. I use this idea on fence posts that always eventually rot right at ground level to keep them from being knocked over too easily!
Thanks for the feedback. The info of this video came from Glenn at buildingcodecollege.com/
Interesting comment, thanks.
Load sharing bridging is code in most places..
@@jamesrussell6870 Thanks! I didn't know it was called "load sharing bridging". I've never seen this done by anyone else, and for me it was just solving a problem using basic physics. I'm a DIY handyman type with no formal training in construction.
@@paparayg It's just called bridging. Primarily for sharing load with adjacent members...
Love this!!! About to take the residential contractor exam.
Nice. Best wishes to you. Post how it goes.
Thank you. This explained a lot of questions I had about why stick frames are built the way they are.
Thanks for watching, Cindy.
If you an at the load limit of a joist, and change the centers to 12 inch centers and glue and screw the sub floor would it be as good as if you used wider joists on standard centers?
Thanks for commenting. Good question.
I added blocking to a 1922 home we owned. It made a huge difference.
Glad to hear it.
I clicked the video thinking to get some guidelines about what size joists and what spacing to use in what situations, which I'll have to look into further... But it did make me thinking about the blocking: If putting blocking halfway the span prevents the joist to flop over, effectively halving the span over which the joist can twist, does halving the span again by adding blocking every quarter of the span add much stiffness to the construction, or are the gains compared to just one row of blocking in the middle negligible?
We're talking about a span of 175" which will be realized with 3" x 9" joists (can't go higher because of ceiling height). I'm thinking about placing them 19.2" on center with 1 or if useful 3 rows of blocking. I could do 16" on center, but I prefer not to as the beams will stay visible from below and more beams closer together would result in a busier looking ceiling, even without blocking...
Thank you for watching and making a good comment.
What was the load per square foot regulations for floors back in the early 1900s? I know currently it’s 40lbs per square foot, my house was built in ‘26 and I was wondering if it would be safe to put a 670 pound safe upstairs?
Good questions. Thank you for watching.
When doing my new home construction, my builder stated a span of 14 ft. was too wide to use the standard LVL's. My homework revealed the possibility of using a Flitch beam. Instead of ordering it from Australia, I made one in my garage. You might consider looking this up, if you run into the same issue.
I will. Thank you.
Thanks for this video. I was worried that the floor spans in my Minecraft castle might be too long, but this helped me to understand why some of the historical floor plans I've seen had >10 m wide rooms with wooden floors -- medieval contractors probably didn't care about floor sag as much as we do today (and trusses probably helped too). Now I can build my 10 m wide wood floors without worrying about historical accuracy. I'll just have to remember not to put all my chests in the middle of the room.
Great to hear! That info comes from Glenn Mathewson of buildingcodecollege.com/.
Good to the point, helpful information! Liked it a lot! Thank you!
Thank you, Nico.
Do I need support on every 2x6 joist spanning approx. 11 feet in the middle or will adding joist hangers on those joist be sufficient?
Good question.
i can't find resources to explain the charts. trying to design 2nd floor. post frame 8' apart columns 2x8" 3 ply. 20'x40. put leger board into columns baloon frame style at the gable end and in the middle of floating slab add pier columns for the opposite side leger board. I can add up the lbs going onto each column but I don't understand how to read the LVL charts.
Thank you for commenting and for watching our videos.
Well presented for those who need to learn the basics.👍👍👌👌
Thanks a lot
So if my calculations are correct, using L/360 when using 12’, 2x6 lumber for a shed floor joist means it is acceptable that the 2x6 bow a maximum of 0.4 inches? I’m currently using 3, 2x6 joists 16” on center spanning 12 feet. I did do blocking. The center joist is currently bowed 1/4” and I’m not done adding all the totes with seasonal items on the loft. I’m thinking about sistering at least the center joist. Thoughts?
Correction, I’m talking about a shed loft, not shed floor.
Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
For an unknown heavy static load spread over the 12' width of the loft: 2x8 minimum or 2x10 prudent.
Very interesting and above all informative .. tone, voice and content are perfect … just wish you were able to provide us with drawings or pictures for each case it makes it way easier for your audience to understand faster or make sure we have the same idea in mind … I’m nonetheless very grateful for the great explanation you granted us with in this video!
Good comment and advice, Thomas. I'll do better next time.
I am a visual person so I have to see it so having a pictures or drawings illustrations that would be perfect that would be nice if could do part 2 with images would be amazing.
Just a thought.
Thank you so much.
Thanks, I am building a log cabin with 30 foot span however I am installing footing piers every 10 feet and was wondering about floor joist loads
Yes.
You need help buddy!
Thanks Ben, learnt something and enjoyed your presentation. I know that seasoned and unseasoned timber have different ratings as well.
Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
Are joist hangher usefull. When (what condition) should you put them in?
Are 9 in joist long enough for a house floor?
Thank you for watching. That information is from Glenn Mathewson from buildingcodecollege.com/. Check him out.
One point I would like to add from the real world is the effect of knots in joists. During an inspection, I saw a garage ceiling with 2 x 8 joists. Three consecutive joists had a knot in the bottom edge about three inches deep. They had deflected about two inches and were starting to crack along their length from the top of the knot. I would say that the framer should have been hung from those joists for using those particular pieces, but he'd probably escape unharmed.
😅
You're correct. Good point about knots in solid lumber. They're like bored holes.
Great information, I have a 1950s single story with water damaged floor and floor joist. They're 2x8s could I replace them with 2x10 with a notch cut out on the outer bottom edge?
I wouldn't do it. That notch in the bottom creates a perfect place for a split to start as well as making the extra two inches useless. Find a way to lower the support base or use 2 x 8s
@@stratocruising i looked underneath and the floor joist have sunken in at the end on the outer foundation. Its at most 1/8 to 1/4 in. can a shim work underneath there or would the joist need to be sistered?
@@luisfigueroa7851 Not exactly sure what has deformed; has the outer foundation (Wood, I assume) collapsed slightly or is the floor joist now smaller than 2" x 8' at the end? if it is the first, a shim would work, but make it broader than the joist bearing on it to spread the load out over a larger surface. If it is the later, I'd sister it for the first 2-3 feet
@@stratocruising thank you, I think its the first where the wood that rest on the foundation (in my situation) has settled or got squished over time. Ill make my plan of act soon. Again thank you for the information.
Thanks for watching, Luis. Good question.
Good info on holes in joists, but what about the diameter of holes? Can I safely run a 3" drain line through a 2 X 10 Joist?
Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
Explained perfectly 👍 Thanks
Glad it was helpful!
Can anyone give an answer, making a horizontal roof with 5 x 30 cm wood joists (30 cm being vertically) would the joists in 5 meters length bend from it's own weight and snow ? And what is the max spacing required between joists, is 70 cm enough ?
Good question. Ask Glenn Mathewson of buildingcodecollege.com/ who wrote that content.
i understand this question is for my structural engineer but wanted to see if you would have an answer. we have a 32 feet wide 130 feet long structure.. the floor would be hollow core precast slabs. what would be the size of the columns and beam to hold the weight of each precast slabs without any support in between 32 feet width?
Thank you for watching. That information is from Glenn Mathewson from buildingcodecollege.com/. Check him out.
Slab on grade for the floor. If you mean second story floor? Your ignorance is showing!😄
We have a newer home less then 2 years old with 2x10 floor joists and I noticed that one of the joists has a horizontal crack about 18 inches long on one end of the joist that rests on an LVL beam. This crack is in the middle area of the joist width as you indicated in the video and is about 1/16 of an inch wide. There is nothing significantly heavy sitting over the area in the floor above the joist. Is this any kind of concern?
No, it will not fail. Easy to repair if there are no wires or pipes going thru that section. Just sister some 2x10 or 3/4” plywood on both sides. Construction glue and nails.
If sistering is not possible get some large mending plates and hammer them on the cracks. I would squeeze some construction adhesive inside the crack before doing this.
Thank you for watching. That information is from Glenn Mathewson from buildingcodecollege.com/. Check him out.
Unfortunately there is a lot of wiring that passes through the joist so that would require pulling all the wiring from the panel. I will monitor it for now as it has not changed in size or diameter.
@@p51mustang31 Cut 3/4" plywood as if there were no wires, then drill for the wires and cut the patch to split it at the wires. The glue and screw it in place. Do that to both sides.
What I see a LOT in houses I've worked on for restoration is holes for wiring and plumbing being drilled far too close to the tension portion of a joist, sometimes even notches cut right out of the bottom. Not only is this annoying because when cutting through or tearing down ceiling drywall you have a high risk of damaging electrical and plumbing (not to mention people who do that never put up nail guards), but it effectively reduces the strength of each joist by how much was cut or drilled out. What's more, if someone else goes in and drills additional holes in at the proper distance, now they're cutting though the new tension point that the first person created, further reducing the load the joist can handle.
Thank for watching the video about simple spans of floor joists. The content was provided by Glenn Mathewson at buildingcodecollege.com/.
Hi, i live in Mass, and I want a marble fireplace the guy who selling it says its about 600 lbs I live on the 3rd floor the room is 384 square feet. It's about 20 feet long and 12 feet wide. Would it be safe to have?
I am not good in math and don't know anything about the subject. I'd appreciate any help
Thank you. The content is from buildingcodecollege.com/.
Topic very well explained! :) But in my opinion it would be even 100x better with ilustrations of what you are describing at the moment.
Great suggestion!
Beautiful explanation- concise
Glad it was helpful!
Very interesting information. Thank you! Almost couldn't see the speaker other than his arms and face... 🙂
Sorry about that.
Excellent video!
I am certain to refer to it in coming project.
Please do!
I just did some 2x10 blocking in my basement area for the living room above, that is always bouncing when the kids play.
Some of the blocks fit ok and some are a little tight/loose. I used long general purpose wood screws. Floor seems more stable, but when I walk into the living room in the morning I hear a few loud cracks/pops. Seems like it's only once or twice a day. It's not my subfloor since I screwed the plywood down before laying 3/4" hardwood a year ago. What's this popping noise and should I be concerned? This is only a 21" section I blocked.
My span is 14' and the house is 32 years old. Home was built with the 1x3 diagonal bracing, but that stuff wasn't helping it seems.
Glad you enjoyed watching the video.
The popping sound is the loose fit of the blocking. Since you screwed in the blocks, remove the loose ones and replace with tighter fitting blocks. Add more blocking every 4' along the length of the joists and cut them to fit less loose. One row of blocking in the middle is not adequate.
Loose blocking is NO blocking! My old boss made me tear out and start over.
An old joiner once told me half span plus 1, so a span of 10 feet/2=5+1=6, joist required=6x2
I was taught the same.
I love those old-timer rule of thumbs.
@@BenGromicko Dont use a screw when a nail will do, Geof Hirst RIP
@@georgeliquor2931 Nice.
Related to notches in the ends of joists. I remember reading something that claimed that strength of the joist is more complicated than simply the depth at the ends, i.e. that if you have a 2x12 joist and you cut 2" x 2" out of the bottom corner on each end, the joist is not reduced to effectively a 2x10 joist, that it's still stronger than a plain 2x10. Is that true?
Good question. Ask Glenn Mathewson of buildingcodecollege.com/ who wrote that content.
Just stumbled across this vid and WOW!! Awesome! Thank you for sharing this information!!
Glad it was helpful!
Best joist would be a steel plate sandwiched between timber. Any timber joist in a house would be bouncy one way or another, prone to horizontal cracks in the middle over 30-50 years, unless it's the size of a tree trunk. Builders make houses just enough to coope with the regs, calculations are 'just enough', no space for 'just in case' load would be 100-200kg more. Omnishambles. Steel frames for structure and glass and wood for decor ought to be the future.
Good comments. Thanks for watching.
Awesome information & explanation!!
Glad it was helpful!
Thanks for the Info, The Outline how it was explained was great
Glad it was helpful! Thanks for watching the video. The information about spans comes from Glenn at buildingcodecollege.com/.
TY I actually learned some things from this video.
All homes should be inspected by an InterNACHI certified home inspector at www.nachi.org/certified-inspectors. Thanks for commenting. - Ben.
the home inspectors im my area will do a slow drive by and look at the framing inbetween swigs of old grand dad and give a thumbs up. Its ok because the “framers” here from south of the border have no carpentry education at all.
The city here will approve anything since they arent responsible for problems and the builders go in and out of business yearly. Very shoddy work in the south.
Thanks for watching and commenting.
This is fantastic information. Thank you!
Glad it was helpful! The info came from Glenn at buildingcodecollege.com/
wow...in simple terms....thanks...this video was just what I needed...all my beams are solid teak and I was worried about the span I am building....not anymore!
That info was provided by Glenn Mathewson from buildingcodecollege.com/.
This is really helpful but can you please have visuals for those that Learn with visual presentations.
Yes. The content was provided by Glenn at buildingcodecollege.com/.
Great information and well explained, and you hit many important points. However, I learn best with diagrams and photos. If you revise this video, please add a diagram or photo for each point you make. If that were the case, this would be a KILLER video!
Thank you. The content is from buildingcodecollege.com/.
Where is there the same analysis to steel framing? Thanks.
Not sure.
Amazing video, thank you 🙌🏽
You're so welcome!
I wonder if joist flop over is similar to when I was a little kid and decided to do a tight rope walk on the edge of the cat's litter box. I balanced myself so the plastic edge of the litter box was supporting my weight, but it tipped over at mid-point. I think it's because the plastic started to buckle causing a twist in my applied weight. There was a solid support for my weight at the box corner but when I got mid-point something like torsion was created. Of course, my mom was not happy about me using the cat box for stress testing.
Thanks for watching. The info of this video came from Glenn at buildingcodecollege.com/
So how far can my double lvl span?? (1 3/4x7 1/4).. addition to my garage 30x30. Using these lvls cause I have 5 million tgi’s in my garage. I’m doing a triple 2x10 in center, piers 7.5’ so 5 piers in center. On my gable side is my steel which I know is good. The overframe side that lands on my existing garage roof is where I’m putting these lvls. 8’ away.
Good questions.
Why you need blocking or something underneath like drywall
Blocking is strengthening.