if compressor tripping LP and HP,
how many reasons
• PCB tripping light bli...
and All your questions will be answered
on this channel about air conditioning
इस चैनल पर आपके सभी सवालों का जवाब
दिया जाएगा एयर कंडीशनिंग के बारे में
so Please subscribe to the channel for
easy way to learn air conditioning work
एयर कंडीशनिंग का काम आसानी से सीखने
के लिए कृपया चैनल को सब्सक्राइब करें
So join my TH-cam ▶️ channel
तो मेरे यूट्यूब ▶️ चैनल से जुड़ें
And this channel talks about A to Z air conditioning on each and every topic
और यह चैनल हर विषय पर A to Z एयर कंडीशनिंग
के बारे में बात करता है
in this channel you will get complete information about Chiller, Air Conditioning & HVAC, Split, Freestand, Window, Ductable,Washing Machine,Unit,etc, and it is explained very clearly and practically in videos in a very easy and simple way.
इस चैनल में आपको चिलर, एयर कंडीशनिंग और एचवीएसी, स्प्लिट, फ्रीस्टैंड, विंडो, डक्टेबल, वॉशिंग मशीन, यूनिट आदि के बारे में पूरी जानकारी मिलेगी और इसे बहुत ही आसान और सरल तरीके से वीडियो में बहुत स्पष्ट और व्यावहारिक रूप से समझाया गया है।
i have uploaded the video of what is the problem in the HVAC, or air conditioning unit and its solution.and open video link and watch video
मैंने एचवीएसी या एयर कंडीशनिंग यूनिट में क्या समस्या
है और उसके समाधान का वीडियो अपलोड किया है।aur
वीडियो link खोलें और वीडियो देखें
#homework#airconditioner#ac#electricity #hvac #hvacwork #airconditioner #ac #electricity#compressor how troubleshoot the hvac system l What is the common problem of the HVAC system? #split #overheat#overheating #hvacwork #airconditioning
vfd dc blower motor speed How to increase,
• Ductable fcu unit vfd ...
AC Blast kyu Hota part 1
• Air Conditioning Kyu B...
how to troubleshoot hvac
• how to troubleshoot hv...
error F2 inverter
• ERROR F 2 . INVERTER C...
error F 5 inverter
• ERROR F5 #inveter #hva...
indoor outdoor wiring inverter
• connection AC indoor t...
error code PO inverter
• error code P0 #erro...
• Video
girls are cleaning the filter of the split AC
indoor to outdoor wiring duct AC
inverter compressor
• Indoor to outdoorLearn...
compressor overheat
details explained in Hindi P2
• why does the compresso...
fire alarm system wiring
• Fire alarm system wiri...
valve repairing
• Video
COND motor wiring
• package unit condensso...
screw compressor rotor
• screw compressor & ROT...
ice on the expansion valve
• How much reason for th...
cooling coil ice PAC AC
• PACKAGE UNIT कूलिंग कॉ...
ABB VFD wiring
• ABB VFD CONTROL WIRING...
TW & CX wiring
• TW and CX model wiring...
chiller SSPS
• This type of SSPS is u...
how to find out the problem
• How to find out proble...
3 phase compressor pumping failure
• What are the effects o... u
zamil package wiring
• full wiring practical ...
why compressor getting high amps
• why compressor takes h... (E)
• 3 फेज कंप्रेसर ज्यादा ... (H)
dainik error F3
• daikin error code F 3 ...
compressor grounded and replace
• package unit new scrol...
How many reasons are
there for bearer tripping
• How many reasons are t...
how to test pumping pressure
• how to test compressor... i
compressor over heating why
compressor overheating P 1
social media link 🔗
UTUBE
/ @hvacamjadtroubleshoot
follow Facebook page
HVACAMJAD
www.facebook.c...
facebook 📷
www.facebook.c...
Instagram📷
/ khan
amjad635?igshid=ZDc4ODBmNjlmNQ
bhot acchi thi video bhai shukriya
Maa shaa Allah, alhamdulillah,
Thank for liking my video jnab ❤️👍
Very knowledgeable
Explanation. Thanks
Thank
Good one sir jii
Thank
Mashallah very good sir
Thank
U r explain very well bro
👍👍❤️💯💯❤️❤️👍👍
Bahut achi video h.uske saath agr digram paper ka mil jata
OK sir
And thanks for liking my video bro 👌👍
Hi sir I watch your video, so effective thank you ❤
Thanks for liking my video 👍
मेरा वीडियो पसंद करने के लिए धन्यवाद 👌
Bhaijaan nicely explain
Thank for liking my video bro 👍❤️
MashaAllah very good sir g
❤❤❤❤❤❤
❤️💯❤️
Nice
Thanks
Meri payer ka bahi jo admi aj pehela kammpe ayata o admi ko aj video dekhra ha he to insaallah o admi ko technition ho jaiyega jeche ap batya.point by point ap puro system me bataya diya.masallah
Alhamdulillah ...
Amjad bhai ALLAH APPKO IS VIDEO'S KA SADAQA -E- ZARAIYA jisa appke iska sawab ata farmana aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaamen..
Ameen
Jazakallah khair bhai
Mashallah Bhai
Very good explanations sir
Thanks bro for liking my video
Super
Thanks
❤
Same card for skm .... manufacture in India
Well explained
Thank
Bhai oil pressure switch aur lp hp ki ek vidio banaye jazakallah khair 👍👍👍👍👍
Ok bro
All efficiency depends on type of tropical compressor..... Cos multi type gas compressor not have any efficiency...
Hi
Hello🙋♂️
Hi
Hello👋
Zamil paket ac ke parts ke bhi nalege de please sir
Ok 👌bro
Bhai agar pcb me lp hp cheka kar na hai ... Unit off ho to ......continite bata ga ki nhi dono me lp me aur hp me ....batao bhai
Jnab is ke 2 Tarah ka wiring
Hota hain kuch unit main off
Nhi batayega aur kuch unit
Main continuety batayega
Sir model CX075HSS zamil ke wringing ke bare me ho sake tu video ka link de .thanks
th-cam.com/video/kO8c5MsQoqw/w-d-xo.html
bro please open video link and
watch the video CX model ka wiring
Bhai zamil coolline package unit dx hai jo ddc painal me air flow switch likhkar arha hai .... Jaise on karo do ye 3 mint baad hai .. kya check karo bhai batao plzz
Aap ne sawal thora sa short mai
Kiya hain
Aapka sawal hai ki air flow ka ddc panel mai alarm araha hain aur
3 min Baad unit off or trip ho jata hai
Agar aisa ho raha hain
Tou sabse phale v belt
Check karo fully tight or not?
2nd air flow switch check karo
Aur air flow switch ka flexible
Hose bhi check karo?
3rd damper fully open or not?
4th bag filter bhi check karo
Clean or not?
What is the reason of compressor trip 3,4 hours worked , normal pressor normal amper there is there is no indication but compressor will trip what is the reason sujest me please
Bro
FYI
What is the unit model?
The model of the unit is very important, because each model has different spare parts.
And whether the compressor contactor is overloaded or available in this model?
if yes then check overload continuity and also check overload setting and need to check some things like
condenssor coil dirty or not
voltage
air filter
dumper
V belt loose or tight
Lp or hp Koi bhi kharab ho Gaya hai to bypass kaise kare zamil AC m
Video banayenge bhai laikin hp aur lp ko sirf testing ke liye hi bypass karen
Ager no ko nc me connect ker de to kya hoga
Bhai agar aisa karoge to aapko connection direct kar dena chahiye aur phir auxiliary ka koi kaam nhi
Aur agar no ko nc karoge jab compressor
off hoga tab bhi compressor on ka indication dikhayega
Sir thermostat w1 w2 wire ka name kiya
Bhai
W1 heater stage 1
W 2 heater stage 2 ke liye
Zmail package unit ..device naam ka introduction btaye
Ok 👌
Sir 1A aur 1B kaha se aa raha he samjae zara Q k waha per video kuch stop ho gae he
th-cam.com/video/aqtBBLhgL-Y/w-d-xo.htmlsi=ZPZ-hDG-hoqF6clP
Please watch bto
th-cam.com/video/U2cJAEcmkhw/w-d-xo.htmlsi=BPGeu_i6yFM_p7U4
th-cam.com/video/ZGTYyEiKqO4/w-d-xo.htmlsi=d3myt9izA4X0IDxr
th-cam.com/video/TxswAZYzWM8/w-d-xo.htmlsi=VRru1DkGN7BP4EeA
Amjad bhai ap ka nmber mil skta hy mujhey air cooled chiller ke bare me ap se pochna hy me zamil compny me neya aya ho plz
bhai
Aapka koi sawal hain comments
Box mein Kare, ek saath jawab
sabko mil jyega
Aur raha number ki baat sorry
And please 🙏 bro kyuki bahut
Hi Jyada call message araha hai
Mere phone pe, aur mai khud ek
Technician hoon season ka time
Hai mere par bahut work and
report load Bahut jyada hain,
So please don't mind bro
Sir realy ke bare me video bane he tu link sher kare AR realy FR realy
I will make a video but please🙏wait bhai
Asslam O Alikum sir
Pcb say 2 numbar compressor ko power ni milti sab kuch ok he gas sarwais sab
Sir 2 numbar comp ko katni time ke bad pcb sy power milti he
Or sir aik or ac he os me Lp sy trip krta he comp k on hote hi lp sy trip krta he or jasay hi comp bad hota he Lp sy contine krta he on hote hi ni krta gas bi ok he
Bhai
Compressor two 2 ko do se 3 minutes
Ke baad pcb se command milta hai
Aur agar comp 2 on nhi ho rha hai
Tou sab se phle C & Y2 mein 24 volt
Check karo
Aur dusra ac pcb mein jab bhi light💡 blinking kare, and check some things like
loose connection, lp, hp switch, freon,
Condenser coil dirty or not
Air filter dirty or not
V belt
Air dumper
Sir power bi ari he pcb bi ok he new he
Or Lp switch ko jampr krdu tu si chal ta je amp bi si he gas bi jampar se khota ho tu lite on hojati he jampar pr si chal ta he gas sab kuch ok he lp switch ka tu problam ni Lp switch cc kye on hote hi off hoja he osi time he 5 sec bi comp on ni hota
@@AbrarAhmad-sx7iq
Bhai
Agar pcb replaced kiye ho
Tou pcb mein DP switch hai
Aur dp switch number 1,2,3
Ko on kardo aur karna chahiye
Aur dp number 1 always off rakhne
Please
@@AbrarAhmad-sx7iq
Us main ek aur bhi switch hain
Anti ice usko bhi check karlo
Wo kaha pr he sir anti ice
Bahot confused karke bataa rahe ho 😢😢
Bhai kis tarah ka confusion ho rha bhai ko?
Bhai mujhe apka number chahiye
Bhai pls number nhi maang kyu
Bahut jyada message aur call
Araha hai aur sabka jawaab dena
Bahut muskil hain please🙏 don't mind
Zamil AC m Lp or hp kharab ho Gaya ho to bypass kaise kare plz bataye
Sar aap apna mobile number dijiye
bhai
Aapka koi sawal hain comments
Box mein Kare, ek saath jawab
sabko mil jyega
Aur raha number ki baat sorry
And please 🙏 bro kyuki bahut
Hi Jyada call message araha hai
Mere phone pe, aur mai khud ek
Technician hoon season ka time
Hai mere par bahut work and
report load Bahut jyada hain,
So please don't mind bro