![HVACAMJAD troubleshoot tips](/img/default-banner.jpg)
- 1 342
- 1 348 557
HVACAMJAD troubleshoot tips
เข้าร่วมเมื่อ 26 ธ.ค. 2021
FRIENDS WELCOME = HVACAMJAD
This channel will give the Helpful tips IN theory and practice for easy trick & troubleshooting.about Chiller, HVAC,Package Unit, So if anyone needs knowledge about the refrigeration and HVAC & Airconditioning so you can LIKE, SHARE, SUBSCRIBE, And if anyone has any questions about HVAC& Air conditioning you can ASK & subscribe for AC KNOWLEDGE📚📚📚 Thanks for supporting
Keep loving🙏
Inspired them
#hvacinformation
#hvacgayan
#spiredingzone
#airconditioner
#youtubewalebaba
#spiredinggayan
#hvac
#actechnician
#acrepair
#anshvlogs
#emmvlogs
#coolingpoints
TH-cam account
youtube.com/@HVACAMJADTROUBLESHOOT
Instagram account.
asgarkhan8310?igsh=MWJhcjJ4cWtoNDFldQ==
Facebook account
khanamjad635?mibextid=ZbWKwL
This channel will give the Helpful tips IN theory and practice for easy trick & troubleshooting.about Chiller, HVAC,Package Unit, So if anyone needs knowledge about the refrigeration and HVAC & Airconditioning so you can LIKE, SHARE, SUBSCRIBE, And if anyone has any questions about HVAC& Air conditioning you can ASK & subscribe for AC KNOWLEDGE📚📚📚 Thanks for supporting
Keep loving🙏
Inspired them
#hvacinformation
#hvacgayan
#spiredingzone
#airconditioner
#youtubewalebaba
#spiredinggayan
#hvac
#actechnician
#acrepair
#anshvlogs
#emmvlogs
#coolingpoints
TH-cam account
youtube.com/@HVACAMJADTROUBLESHOOT
Instagram account.
asgarkhan8310?igsh=MWJhcjJ4cWtoNDFldQ==
Facebook account
khanamjad635?mibextid=ZbWKwL
compressor comman problem in hindi ll #compressor #hvactraining #hvacamjad
compressor comman problem in hindi ll #compressor #hvactraining #hvacamjad
มุมมอง: 347
วีดีโอ
Air conditioner question in hindi & troubleshoot tips, l #hvactraining #airconditioner #hvacamjad
มุมมอง 28514 วันที่ผ่านมา
Hvac interview questions and answers Part 1 HVAC unit troubshoot tips part 1 th-cam.com/video/bjnrgYf2vJo/w-d-xo.htmlsi=dvN8K-YQnRC3fC4N Video Part 2 th-cam.com/video/wI_04IZRsx8/w-d-xo.htmlsi=o1HmSzYymTm3SYhs Compressor kaise check Kare th-cam.com/video/O53TphDupkU/w-d-xo.htmlsi=yt_9KEvNP9lil4VZ
hvac interview questions in hindi, #hvactraining #troubleshooting #hvacamjad
มุมมอง 18414 วันที่ผ่านมา
Hvac interview questions and answers Part 1 HVAC unit troubshoot tips part 1 th-cam.com/video/bjnrgYf2vJo/w-d-xo.htmlsi=dvN8K-YQnRC3fC4N Video Part 2 th-cam.com/video/wI_04IZRsx8/w-d-xo.htmlsi=o1HmSzYymTm3SYhs Compressor kaise check Kare th-cam.com/video/O53TphDupkU/w-d-xo.htmlsi=yt_9KEvNP9lil4VZ
package AC not heating ll HVAC troubleshoot, ll #electrical #acwork #hvacamjad
มุมมอง 263หลายเดือนก่อน
package AC not heating ll HVAC troubleshoot, ll #electrical #acwork #hvacamjad
high suction pressure resolved in hindi, #hvacamjad #hvactraining #hvacwork
มุมมอง 246หลายเดือนก่อน
high suction pressure resolved in hindi, #hvacamjad #hvactraining #hvacwork
AC COMPRESSOR trip kyu hota hai, l compressor tripping problem & solution #hvactraining #hvacamjad
มุมมอง 187หลายเดือนก่อน
AC COMPRESSOR trip kyu hota hai, l compressor tripping problem & solution #hvactraining #hvacamjad
LOW SUCTION PRESSURE AC TROUBLESHOOT ll #hvacamjad #hvactraining
มุมมอง 2362 หลายเดือนก่อน
LOW SUCTION PRESSURE AC TROUBLESHOOT ll #hvacamjad #hvactraining
water service with jet pump l package AC preventive maintenance l zamil package AC l water service
มุมมอง 992 หลายเดือนก่อน
water service with jet pump l package AC preventive maintenance l zamil package AC l water service
belt drive pulley alignment practically in hindi ll pulley adjustment hvac ll #acwork #hvacwork
มุมมอง 2682 หลายเดือนก่อน
belt drive pulley alignment practically in hindi ll pulley adjustment hvac ll #acwork #hvacwork
HVAC TROUBLESHOOTING ll #hvacamjad #hvactrainingvedioes #acwork
มุมมอง 1432 หลายเดือนก่อน
HVAC TROUBLESHOOTING ll #hvacamjad #hvactrainingvedioes #acwork
compressor terminal blast reasons ll compressor C S R terminal burn? #hvacamjad #acwork
มุมมอง 1292 หลายเดือนก่อน
compressor terminal blast reasons ll compressor C S R terminal burn? #hvacamjad #acwork
electrical duct heater ll hace electrical heating air conditioner wiring
มุมมอง 1102 หลายเดือนก่อน
electrical duct heater ll hace electrical heating air conditioner wiring
3 phase compressor troubleshooting in hindi ll how to check HVAC COMPRESSOR, #hvacamjad #hvacwork
มุมมอง 3962 หลายเดือนก่อน
3 phase compressor troubleshooting in hindi ll how to check HVAC COMPRESSOR, #hvacamjad #hvacwork
phase condenser fan motor wiring l learn condenser fan motor star and delta wiring l zamil packageAC
มุมมอง 2112 หลายเดือนก่อน
phase condenser fan motor wiring l learn condenser fan motor star and delta wiring l zamil packageAC
AC TROUBLESHOOT ll package AC troubleshooting ll #hvacamjad #acwork
มุมมอง 1822 หลายเดือนก่อน
AC TROUBLESHOOT ll package AC troubleshooting ll #hvacamjad #acwork
DDC panel kya hota hai full details ll what is #ddc ll DDC PANEL shnieder #hvacamjad #hvac
มุมมอง 2472 หลายเดือนก่อน
DDC panel kya hota hai full details ll what is #ddc ll DDC PANEL shnieder #hvacamjad #hvac
AC cooling not working, ac thanda nahi kar rahi hai, how to repair air conditioner at home, in Hindi
มุมมอง 1642 หลายเดือนก่อน
AC cooling not working, ac thanda nahi kar rahi hai, how to repair air conditioner at home, in Hindi
AC not blowing cold air ll #hvactrainingvideos #airconditioner #hvacamjad
มุมมอง 982 หลายเดือนก่อน
AC not blowing cold air ll #hvactrainingvideos #airconditioner #hvacamjad
why ice formation on cooling coil in hindi - urdu ll cooling coil freezing ll #split #acwork
มุมมอง 1103 หลายเดือนก่อน
why ice formation on cooling coil in hindi - urdu ll cooling coil freezing ll #split #acwork
monitoring Relay phase & voltage in hindi ll #hvacamjad #hvactrainingvideos
มุมมอง 2293 หลายเดือนก่อน
monitoring Relay phase & voltage in hindi ll #hvacamjad #hvactrainingvideos
what is RCBO circuit breaker ll RCBO breaker kaise kaam karta hai, #electrical #breaker #hvacrepair
มุมมอง 563 หลายเดือนก่อน
what is RCBO circuit breaker ll RCBO breaker kaise kaam karta hai, #electrical #breaker #hvacrepair
how to check compressor defective or not in hindi - urdu ll faulty compressor test with maltimeter
มุมมอง 2083 หลายเดือนก่อน
how to check compressor defective or not in hindi - urdu ll faulty compressor test with maltimeter
how to check transformer primary & secondary using Clampmeter (in hindi-urdu ) #hvactrainingvideos
มุมมอง 1733 หลายเดือนก่อน
how to check transformer primary & secondary using Clampmeter (in hindi-urdu ) #hvactrainingvideos
how to install filter drier (refrigeration) in hindi - urdu ll. #airconditioner #hvacrepair
มุมมอง 2163 หลายเดือนก่อน
how to install filter drier (refrigeration) in hindi - urdu ll. #airconditioner #hvacrepair
what to check before turning on AC in hindi - urdu ll AC चालू करने से पहले क्या जांचें? #hvac
มุมมอง 2723 หลายเดือนก่อน
what to check before turning on AC in hindi - urdu ll AC चालू करने से पहले क्या जांचें? #hvac
AC motor shaft broken in hindi - urdu ll what happened if condenser motor damage ll #hvacrepair
มุมมอง 1273 หลายเดือนก่อน
AC motor shaft broken in hindi - urdu ll what happened if condenser motor damage ll #hvacrepair
what is the LP & HP pressure switch l LP और HP क्या है और यह कैसे काम करता है in hindi - urdu
มุมมอง 1733 หลายเดือนก่อน
what is the LP & HP pressure switch l LP और HP क्या है और यह कैसे काम करता है in hindi - urdu
How to start the motor directly? in urdu - hindi l मोटर को कैसे चालू करें? ac motor direct test
มุมมอง 1313 หลายเดือนก่อน
How to start the motor directly? in urdu - hindi l मोटर को कैसे चालू करें? ac motor direct test
how to check capacitor in hindi - urdu
มุมมอง 1574 หลายเดือนก่อน
how to check capacitor in hindi - urdu
Air conditioner capacitor testing in urdu - hindi l Compressor capacitor ko kaise check Kare #hvac
มุมมอง 1654 หลายเดือนก่อน
Air conditioner capacitor testing in urdu - hindi l Compressor capacitor ko kaise check Kare #hvac
What type of welding rod can be use like copper, sliver, brass rod
Brass brazing rods is used for welding copper
To iska poora banayiye janab.
👍
Assalamualaikum sir Package unit m thermostat bilkool off hai ye thermostat kharab ho gya h es ko new thermostat change kar ne par package unit off hona chahiye
Walaikum Salam wr wb bhai Yes agar thermostat ok hain Aur jab aap Thermostat ko Turned off karte hain to unit off hona chahiye laikin agar Thermostat Turned off karne ke baad bhi Unit off nhi ho rha hai tou Aap sabse phale command Check karo ki command Stop huwa ki nhi
Sir aap Whatsapp number hame chahiye
+91, 7079911568
Sir aap Whatsapp number chahiye plz trablshoot mastar h aap m aap ka video roz dekh ta hu chainal subscribe kiya hu
Sir ak thermostat hai jo room temperature thik hai 23 h par thermostat m dikh raha room temperature 36 us ka fault room sensor hai sir q du saraa thermostat thik dikh raha h 23 room temperature h
Bhai Yes Laikin bhai sabse phale temperature sensor ko changed kar ke check kare Kyu ki khabhi khabhi thermostat ka Battery week hone se bhi aisa hota hai kuch company ke thermostat mai
Sir zamil ka thermostat hai wo room temperature 36 dika raha aur do sara thermostat 23 room dono akhi jagah h dosara wala thermostat sensor kharab h
Jnab Is ke 3 reasons ho sakta hain 1st temperature sensor 2nd thermostat malfunctioning 3rd thermostat ki battery week Hone se bhi kuch company ke thermostat mai bhi aisa hota hai Bro,
video main samajhya theek per video ney sari mehnat kharab kardi hey video dubara say banain
मेहनत कभी बेकार नही होती, कोशिश करने वालो की कभी हार नहीं होती। bhai ❤️
Pls make a video on cx220 model blower connection
Please watch this video bro th-cam.com/video/kO8c5MsQoqw/w-d-xo.htmlsi=rrzzGuOCQX_hQkAJ
BRO thermostat working but idoor fan and indoor not working what is the fault
Dear there could be many reasons for this bro and u need to check a few things and check thermostat settings And fan settings can be auto or manual if it is in auto then always keep it on manual & also the command signal coming from the thermostat to the PCB needs to be checked
New unit
Salaam brother My condition is little critical can you help me in this same chiller When i ON the chiller circuit 1 is off because work is going on circuit 2 when i ON the compressor starts and maybe 3 to 4 seconds after that it close and i get alarm of ALM SUCT PSI 1 or sometime ALM SUCT PSI 2 or sometime UNSAFE SUCT please can you advice me. Thanks
Also ALM PT1000
Walaikum Salam bro There are many reasons for this You need to check some things First of all check the water pressure In and out line 2nd gas pressure Standing pressure and actual pressure 3rd filter core in out Line temperature 4th What is the water temperature setting And actual And Insufficient refrigerant will cause the pressure in the system to be abnormal, resulting in a decrease in suction pressure, low-pressure alarm of the chiller, and equipment shutdown. The leakage of refrigerant can be from the compressor, condenser, filter, expansion valve and evaporator, etc
Nice ❤
❤
Nice
Hi
Jb assalamualaikum ahu ka filter saaf hai magar bms me ganda dikha raha hai.
Walaikum Salam wa rahmatullahi wa barkatahu bhai, Iske kayi reasons ho sakta hain Sabse phale cooling coil ko check kare clean or not? Pre filter ko bhi check karo clean or not? Bag filter khabhi khabhi bahut dirty Hota hain dekhne mai saaf dikhta Hai aise confirm aur sure hona chahiye ki bag filter 100 % clean hai Ki nhi agar sab clean hai to ek baar Bag filter ko nikal kar bhi check kar sakte ho, Ye sab clean hone ke baad bhi Agar BMS mai dirty show kar raha ho tou air differential switch ka wiring, aur settings check karo Aur khabhi air differential switch Mai ek hose lagta hai aur wo bhi Dirty hone se dirty ka alarm so karta hai bhai,
Good
👍❤️✅
Assalam walikum
Walaikum Salam wr wb jnab 👍❤️
👍💐🐅
👍👍👍❤️❤️👍👍❤️👍
10:40 Acetylene ki psi sayad 15 to 20 psi hota he Or oxygen ka 40 to 45 psi hota he na sir Thoda confuse ho raha hun Bata dijiye aap ki bato ko sun ke
Please read bhai 👇 What oxy-acetylene pressure for brazing copper? Depending on what tip size you're using (1 thru 4 for 1/4" up to 1-1/8") you should set the acetylene regulator for 6-8 psi and the oxygen at 10-14 psi. If you are soldering (or brazing if you prefer) 1-3/8" copper or larger, you're better off using a rosebud torch.
@@HVACAMJADTROUBLESHOOT rosebud ka hi istemal kar ta hu mei jo unit me kaam kar rha hu wo 35 TR Petra unit he mei hamesha esi psi ko set kar ke kar ta hu
How do i find the right code
Dear bro 👇👇👇❤️✅ Make sure it's in standby mode and not running. Point the universal AC remote in the direction of your AC. Press the “Set” button and choose your AC model's code using the '+' and '-' buttons on your remote. Press “Enter” as soon as you see a code that matches the model of your air conditioning unit.
Ahu unit dono mai used hota hai bhai Is ahu unit ke colling coil pe freon gas curculate hoga Aur chiller ke liye jo ahu used hota hai us pe water aur chiller wala ahu ke cooling coil pe Expansion valve nhi laga hota hai Jab is type ke ahu ke cooling coil Mai expansion valve laga hota hai
Welcome ❤
Compressor 8 me alarm aa Raha h :- No Run Kis wajah se No Run aa Raha h
Bro Compressor 8 no run system ko reset karna hoga, Aur bhai compressor 8 mai Is system main problem thaa us problem ko rectify kar diya Gaya thaa laikin reset nhi kiya gaya thaa is liye display pe no run karke alarm araha hai aapko reset button press karna hoga jab khabhi is tarah ka alarm aye❤
ماشاءاللہ 🌹🌹🌹🌹 بہت اچھا زبردست 👍👍👍♥️♥️♥️🌹🌹🌹🌹 Good 👍
Shukriya jnab for liking my video ❤️❤️❤️👍👍👍💯💯💯✅✅👍❤️👍
Mast hai video kuch mila sikhne ko
Thank for liking my video jnab 👍✅
Good sir❤
Thank for liking my video bro 👍❤️❤️💯✅
Can a 380 scroll compressor work on 415 volt help please
yes, but need to be checked compressor amperage and sound
@HVACAMJADTROUBLESHOOT thanks 👍
Sir Rack system comprrsor ko bump down kise krte hain.
Videos banayege bhai is topics Per laikin aapko kuch intezaar karna Hoga please
Vrf system lag raha
Nhi bhai Ye central air conditioner hai
Is unit main 2 compressors hai Aur is ka piping ahu unit ke cooling coil pe ja raha hain bhai
is machine ka kiya naam hai central ac ? Mujhe lga AHU sirf chiller me use hota
Thankss
isi trah bnaye troubleshooting ki ke thora knowledge le saku
Hiter kaha par laga hota hai
Bhai heaters supply duct mai Lagta hai
Chillar mein Kai tarah ki safety switch ka use Kiya jata hai.. like High pressure switch Low pressure switch Anti freez senser Pressure relief valve Water flow sensor Return water temperature Senser Wpt Olp Oil level sensor Temperature sensor Pressure sensor single phase preventer Pds
👍💯✅❤️
Motor running 50HZ if motor running more than 50 HZ after it will trip phase loss. How can rectify this issue
Bhai Please check the parameter settings first. Secondly, are you checking in auto mode or manual mode? And Some checking is needed Check the voltage to see if it is stable and okay. Check the loose connections of power cable, control cable and BMS cable to see if any wire is loose.
Can u explain me how to calculate OPD in screw chiller..
Bhai mai topic per video Banayege
So please wait kare
Ok sir but can u tell me the formula to measure the opd
Tiger zinda hai 🥰💐🌹🐅
Nop when we tight cable also coming same problem
Bhai Need to be checked something Like Please check the voltage?
Thanks for the breakdown! I have a quick question: My OKX wallet holds some USDT, and I have the seed phrase. (alarm fetch churn bridge exercise tape speak race clerk couch crater letter). Could you explain how to move them to Binance?
A video will be released on this topic but you will have to wait.
Good job sir
Thank for liking my video bro 👍❤️
assaalm walykum ek help mil skta hai aap se
Walaikum Salam wr wb Kya help chahiye bhai
Ji assalamualaikum sir FCU ka fan speed ham high mode me rakh Rahe hai magar 2 ya 3 ghante ke Baad display me low bata raha hai problem Kya ho sakta hai...
Walaikum Salam wr wb bhai +91 70799 11568 Please send video Kuan sa company ka unit hai?
Aap No aur NC ke conecsion ke bare me batade sir NC wair kis jagah par lagta hai aur No kis jagah par use hota hai sir
bhai watch this video Baad mai aur video upload Karenge 👇👇👇 th-cam.com/video/NlLcFT5iphc/w-d-xo.htmlsi=ugY9CFjUypYaYhGh
Aap video dekh kar meri kuch problem soal hogayi hai
Alhamdulillah and thank for liking my video jnab 👍💯✅
Good job sir
Thank for liking my video bro 👍✅
Oum
👍💯
Assalamualaikum amzad Bhai. Amzad Bhai ek Trane company ka split ac hai jiska suction to thandaa hai magar discharge normal hai Kya fault AA sakta hai jb..
Walaikum Salam wr wb bhai Is ke kayi reasons ho sakta hain? Why is my discharge line not hot? Need to be checked something Like 1st ambient temperature bahut low Hone se aisa hota hain aur ho sakta hain aur check Set temperature and actual temperature may be Low load/(in some cases) 2nd check ambient temperature Filter drier bhi check kar sakte Ho agar filter drier kuch percent Block hone se bhi aisa ho sakta hain Aur agar sab ok hain phir discharge Pressure Check karo
Compressor ke trip ho ne ke lye sare reason hote he Singal phas unit .... Capacitor ka damag hona Sarvice problem Low voltage hone ke karan Candensar ka block hone ke karan Three phas unit HP ke karan Lp ke karan Wpt kr karan Olp ke karan PDS ke karan Kisi wire ka shoot hone ke karan Campresor me Electrical problem hone ke karan Prv ke karan Anty freez sensar Oil level sensor Watar flow sensar Return watar tumprechar sensar Pressure sensor Tumprechar sensar or v bahut sare Reason hote he sir q he na mei shi bol rha na btayeyga ❤
Jnab aap bahut sahi kaha Mai aapka fan ho Gaya And shukriya apna knowledge share Karne ke liye bhai 👍💯✅
Suction line pressure High hone ke kuch reason hote he Unit me Extra refrigerat hone ke karan MBN tumprechar high hone ke karan Candensing shi se na ho pane ke karan
Bilkul sahi superb bro 💯👍
👍
👍✅