How To Direct Start AC ! AC PCB Is Not Starting Compressor
ฝัง
- เผยแพร่เมื่อ 24 มี.ค. 2020
- How To Direct Start AC ! AC PCB Is Not Starting Compressor
Hi Friends,
I Am Ismail Khan And All Of You Are Most Welcome In My TH-cam Channel Ideal For Technical
In This Video I Have Explained About How To Direct Start AC When AC PCB Is Not Starting Compressor
This Is A Fault Of PCB Due To Moisture
In This Fault PCB Shows That It Is Working But Not Activating It's Relay
This Is A Trick Used In Emergency To Direct Start AC
By This Trick AC Will Run Directly Which Is Very Harmful For Compressor On Sudden Cut Off And On Of Electricity
But On Emergency You Can Do It
Watch This Video And Share It As Much As Possible
Thanks,
About The Channel :-
Dosto Mere TH-cam Channel Ideal For Technical Ke Zariye Refrigeration And Air Conditioning, Electricals, Electronics, Mobile, TH-cam Channel Aur Computer Se Related Technical Knowledge, Tips And Tricks Ke Sath Social Welfare Se Related Videos Upload Kiye Jaate Hai
Videos Ko Dekh Kar Comments Zaroor Kijiyega.
Song/Music:-
Song/music attribution not required provided by TH-cam Library.
Disclaimer:-
Copyright Disclaimer Under Section 107 Of The Copyright Act 1976,
Allowance is made for " Fair Use " for Purposes such as Criticism, Comment, News Reporting, Teaching, Scholarship and Research, Fair use is a use permitted by Copyright Statue that might otherwise be infringing.
Nonprofit, Educational or personal use tips the balance in favour of fair use.
Thank You So Much
#directstartac
#idealfortechnical
Contact For Business Inquiries
ismail05ideal@gmail.com - วิทยาศาสตร์และเทคโนโลยี
Sir ap ki vedeos bahot knowledgeful hoti han aur ap ka parhanay ka style bahot acha hai.
Shukriya,
Mere Channel par new video upload hui hai
Window AC connection With PCB
Isko zaroor dekhiye
Bahut achha laga aap ka ye video bhai thanks
Video acha hai sir
Good explain sir
Bohat khoob Bhaijaan
Shukriya,
Video Ko Khoob Share Kar dijiye
Bhai aap bahut achha samjhe hai
Shukriya
Allah aap ko salamat Rakhe bhai
Allah Pak Ham Sabhi Ko Har Aafat Se Bachaye,
Khas Taur Se Hamare Mulk Me Aur Poori Duniya Me Sabhi Ko Corona Se Mahfooz Kare, Ameen
Good videos sir
Thanks
Bhaiya Hamare Pas Bhi Aisa Hi Window AC hai
👍
Thanks sir
Pl note
We must test compracer continuity test for short circuit etc we do not test property we may loose costly item.only my advise
Wow sir mast video है
Share this video
Great video sir🙏🙏
Thanks 👍🌹
Super Mare Bhai
Sir ji, how to get PCB checked for Panasonic window AC 1.5 Ton, pcb display blinks, all functions led light r randomly on, & display digits r disturbed.
Sir aap ko video me background music nahi lagan chahiye
Sorry
Galti ho gayi
Nice video
Very. Nice. Sir
Your Welcome
Nice
Lajwab
Op sir
Wow sir nice
Thanks, please share it on your all contacts
Aapka new subscriber sir
Your Most Welcome 👌👌🌹🌹
Sir refrigeretir ke compresir ka size kaise Pata Karen ki ye fireg me yah size ka compresir lage GA 1/4 1/5 1/6 please batayn
Nice sir
Thanks 👍👍
Awesome
Share it on Facebook and what's app as much as possible
Windows Ac Front Pannel ko Pani se Saaf kiya tha PCB Bhi Gilla ho gya Hai , Ab kya krna hai , osko Dhoop m sookha le kya ??
Nice bro
Thanks 👍
Bhai only fane mode p laga h ye low speed normal aur high p chalta h compressor
Sir.. Mere window ac ka fan running h lekinn pcb me light nahi aa rhi or na hi compressor on h.. Plz suggest
Pcb ka relay kharab hoga
Direct start kar ke check kijiye
Good information sir👍
Thanks
Boss!my zamil window AC don't restart when temperatures 40°c up .condenser and cooling chamber is cleaned.i tried to restart unit by direct connection from themostat points sparking,not starting compressor.what can be solution please?
Check the capacitor of compressor
Also check the speed of condenser fan
@@IdealForTechnical capacitor good.fan speed ok.Problem is after auto it sometimes restart within 2 minutes, sometimes not start for one hour.I mean random mood.so I don't know why this happens.???
Now almost one hour I switched off and now i switched on but not starting compressor.all other functioning fine
@@HUMAYUNKABIR-ez2rt what is the ampere when u try to restart it
bhai mene new window ac liya hai abhi 1 din hua hai usme bhi yehi problem aa rahi h compressor start nai ho raha
🎉
Thank you sir.
Your Welcome,
Watch my all videos and share them as much as possible
Kya hall hai sir
Sir plz reply dijiye jo reley wala tar hai use aage pichhe kar dena chahiye
AC direct chalana chahte hai to Dono wire ko Ek saath Kisi Bhi point par connect Kar dijiye
It's video for mechanic only
Ye kon sa models ac ka kom sa remote use hota he isme
Lloyd window AC
Same yhi problem h window a.c lloyd pcb button work nii krr rhe 5-10 min m cut maar deta h temperature 29 par rhta h down nii aataa
Sir compressor direct chalnye ki liye relay mein se nikal kar red blue waer ek hi mein jod deyge
Colour Se matlab Nahi, Phase Ka wire Relay ke jis terminal par connect Hota Hai usi terminal par relay Se compressor Ko Jane wali supply wire Ko direct connect Karna Hai
Remote control power supply bord kese check Karen
Sir ap ki online video nahin a rahi 8 vedeo ka bad
Insha Allah,.bahut jald
Sar split AC chalu karne per turant outdoor start ho ja raha hai Sar filed ke bare mein iska video Banaye. Sir. Plese
TH-cam par search kijiye
Wiring of split AC with PCB and magnetic contactor
Apko Mera video Milega isko Dekhiye phir Bataiye
sir plz pcb board ko ac se remove kr k fir without pcb k ac start hona chiye is pr ak video bniye
without pcb
Thanks For Your Suggestion,
As Soon As Possible ,
If pcb is removed by this method and AC is directly powere for cooling..what will happen to compressor
Have you seen manual ac operated by selector switch
What do you think about that
Sir voltas windo ac ki fen motar ko darekt kese chlye bina pcb ke
Fan Motor Me Blue Wire Common Aur Teen Speed Ke Wire Honge ( Black High, White Medium , Red Slow ) Inme Se Red Aur White Ko Alag Alag Tape Lagakar Dead Kar Dijiye, Ab Phase Wire Ko Blue Common Ke Saath Aur Neutral Ko Black High Speed Ke Wire Ke Saath Connect Kar Ke Direct On Kijiye Aur Isi Jagah Se Aap Compressor Ko Bhi Supply Dedijiye
good information 👌👍😎.
Excellent sir
Thank You So Much 👌👌🌹👍
Koi short circuit jaisi problem to nhi hogi na?
Nahi Hoga Shortw Circuit 👍
सर मेरे एसि में एक प्रब्लेम है,आंन होतेहि कम्प्रेसर स्टार्ट हो जाता है,जो कि तिन मिनट बाद होने चाहिए, किया ख़राब हो सकता है!
AC ke PCB me time delay switch Lagi Hoti hai Wo direct on ho Rahi hai
Is switch me Jane wali supply ki PCB circuit me problem ho Sakti Hai
Ya Relay Ka connection direct hoga
Bhi mare ko ye display cable chaiye kha milege m Noida m rahta hu
Mere Bhai,
Mai Uttar Pradesh Se Hoon Aur Aap Noida Se,
Noida Ki Market Mai Nahi Janta
Mujhe Afsos Hai Mai Apki Madad Nahi Kar Pa Raha Hoon
Fan motor 2-4 minut chalkr bnd ho jati h kya problem h ac m pls reaply
PCB ki problem ho Sakti Hai ya fan capacitor kharab ho Sakta Hai
Bhai mere ac ka pcb kharab hai aur start karte hi turant compressor chal jata hai koi dikat to nahi?
Sudden Off On hone me Problem hogi Otherwise koi problem nahi
Circuit digram provide kare.
Watch my video
Wiring of window ac with PCB and sensor
What for you are directly connected power
That point is not fully explain ed
It Was Not Operating By Remote Due To Moisture Problem In PCB,
Customer Has Told Me To Direct It Without Removing PCB
In This Video My Point Is To Trained How To Direct Start AC Without Removing PCB
Sir agar pcb ka Relay hi kharab ho to kaisa without pcb direct start karey
Phase ko fan motor ki high speed wire AUR compressor ke common terminal SE connect Kar dijiye
Aur Neutral ko fan ke common aur compressor ke capacitor par connect Kar dijiye
Aapko knowledge nahi hai
Bhai aise to compressor direct on ho jayega. Problem ho sakti hai aage.
Problem tabhi hogi jab sudden Off On kiya jaye
Aur ye sirf ac repair karwane tak ke liye kiya jata hai na ki permanent
@@IdealForTechnical bhai mujhe mere AC ki relay nai mil pa rahi hai. Mai meerut se hu. Aap kuch help kar sakte ho kya.
Bhai shab compraser to on ho gya but fan motor nhi chli
Video Ko Dhyan Se Dekhiye Aur samajhiye,
Fan ki high speed me Phase Aur Common me neutral dijiye
Sir ye information galat hai quki rellay ki dono wire ko interchang kene se kuch nahi hoga apes me dono wire ko short kerne se comoressor on hoga quki rellay karab hai inter change kane se b dono phase wire ko short nahi karegi rellay
Dobara samajhne ki koshish kijiye
Uske baad bataiye 👍
@@IdealForTechnical aree aap he bta dijiye
Compressor on but not cooling
Check,
Is it required Servicing?
Or mechanical problems may be there such as Choking, gas leakage or pumping failure of compressor
Agar iska aage ka pannel Kam na kare phir kya karen
Aage Display PCB lagi hoti hai iske kharab hone par repair karenge ya change kar denge
Run to krega but rely cut nhi krega
Ji haa apne sahi kaha,
Direct start Karne Ka yahi Matlab to hua 👍👍👌
Ye volum song tik nhi h
Your Welcome,
Thanks For Suggestion
PCB 10 mint chlti h window ac ki uske bad Sara kuch bnd ho jata h
Like nhi bai Jwab chahiye tha
10 Minutes ke baad AC me Supply aana band ho jati ho to MCB check Kijiye
Supply rahti hai to MCB ko Check Karwaiye Iske Resistance Me Kahi koi Problem ho Sakti Hai
PCB me Problem hai Sari Hi Bnd Ho jati h 10min chl k Uske bd fr se chlao to chl jati h
PCB kitne Ampere ki hai
Aur Trip hote waqt AC Ka Ampere Kitna rahta hai
Agar AC Ka Ampere normal SE Zyada ho to Run Capacitor check Kijiye AUR ho sake to Run Capacitor change Kar ke dekhiye
@@IdealForTechnical 3 4 amp hi leta h Bahr nikl kr v chla k dekh li khali pcb 10min hi chlti h 1ton ka Window ac h
😂😂😂
Apna number bhejiye
Couldn't you give the music?
ac on karta hi compresser chalna lagta ha . Kya ya theek ha nhi
Pls jawab jarrur daa ..
Sir refrigeretir ke compresir ka size kaise Pata Karen ki ye fireg me yah size ka compresir lage GA 1/4 1/5 1/6 please batayn
Thanks,
Insha Allah I Will Make A Complete Video On This Topic