Paaji main v ups install repair gulf mein karta hon.. Same to ups 15 kva 3/3 thik kiya tha... Sare problem menual padhny pata chal jata.. Model infosec ka tha,,, thank you sir ji for information,,
I have a problem i put the power wire in the ups but the screen not brighting but when i click on the power button its working and it’s give me error code (Ch) what to do in that case dear ?
Sir nice explanation , 6kva ka ups ha thk chalta ha main py b or battery py b...backup b dy raha ha...matlb all ok ha ...lekin zyada dair chlta ha tu 02 error deta ha restart krain tu chala jata ha ...lekin permanent error ja ni raha ....pls guid
Bhaiyya namaskar. Mujhe same no power/no ups aur screen turn on ki prob. Thi, power supply, dcdc module aur control teeno replace kiye parantu ups on hi nahi ho Raha hai. Power supply externally check kare to ok hai kick start ho Raha hai aur 12vdc bhi AA amrahi hai par ups on nahi ho Raha. Please help.
Depends karta hai how you handle it or apne kis environment mein install Kiya hai, kis type ka load use kar rhe ho. Output Load is the most important thing... and input/output wiring.
@gurjitprincesingh7932 sir mera load high quality premium grade sound system he, iske equipment saare digital he aur bade expensive he, koi bhi tarah ka fluctuation ya spike inko damage kar dega, aur most important, supply me agar high frequency swtching noise present hoti he, to vo speaker me zyada sunai deti he. To output supply bilkul pure sine wave honi chahiye. Ab kya microtek ye kar lega? Kyunki apc thoda expensive hai, nahi to fir apc lena hi padega, please bataiye, thank you
@@burhanuddin127 yes apc is bit expensive but rugged. Microtek is all China based technology, Microtek imports products, as you describe about your expensive products so my opinion is go for APC. It's a one time investment.
sir if output voltage of ups higher then input as example input voltage 225V but online ups output voltage 240V ,no error shows in ups .? then what is problem in ups?
Code 3 raise when mains enter and output will be off . When mains cut then after switching off then buzzers will be stop and again switching on then ups will be started giving output 1 kva 36 volt online ups
Hi sir jee Mera ups Hitachi hirel ka hai ismein error code 01 a raha hai kaise pata Karen ki yeh problem battery ke bajah se hua hai yah main supply ke bajah ,kyun ki Naya ups lagaya tha sir please help me
Risk hota, if batteries are in charging mode then high risk sprak ho sakta hai, If batteries charged, but apko bahut shavdani see karna hoga. Remember connector ya fir batteries wire ups se touch na ho
@@susobhandas1298 jab ups mains mode mein on hotta hai, tab ek bar vo batteries mode mein shift ho Kar batteries chk karta hai, agar batteries support na Kare then it gives 27error.
jab ups mains mode mein on hotta hai, tab ek bar vo batteries mode mein shift ho Kar batteries chk karta hai, agar batteries support na Kare then it gives 27error.
Hello sirji,Good knowledgeable videos, keep it up sir ji... Mujhe kuch doubts the ups related..can I have your whatsapp no.. please sirji.... Mujhe kuch madad mil.jayegi... Mera ups Eaton 10 kva ka hai aur fault code 89 bata raha hai...kaun se sections pe problem hai....Aur kya kya check karna padega iska... Kya aap iska..manual aur circuit diagram share kar sakte hain..please.. Awaiting for your kind response at the earliest.. Thanks..
Hello sir 3kva online microtek ka ups hai 10 min chalne ke bad battery lo bata deta hai but battery indicator full rehta hai kya problem hai 75 ah ki sab new battery hai plz help
Kyun k ups andar DC capacitors hunde ne, oh jado charge hunde ne te spark hunda. Better ehi aa k ya te series ch blub lga k phela capacitors charge Kar lo. Ya fir phela input de k mains te on karke capacitors charge Kar lo fir batteries wali mcb on Kar lo
Paji mai battery wale negative wire te series te bulb laga ke usko discharge kerta hu jab tak bulb full chal ker band na ho jaye fer bhi spark kerta he ji
Hello sir I have an online ups same model like this and I am getting error 41 can you please help what is the problem in my ups. After running 10 mints it's start beeping continuously with error 41
Hello Sir I have an online ups same model like this and I am getting error 11 can you please help what is the problem in my ups ,problem occurred after changed batteries. after running 10 seconds it's start beeping continuously with error 11
Sir kl hi battery replace Kiya to on tha bt aaj on nahi ho raha . Koi error code v nahi hai battery charge v ho rahi . B's on nahi ho raha plzzz solution bataye.
Sir mere 3 KVA Microtech Max UPS me.. Battery Full charge hone par, Battery Mode par aa jata he.... aur Battery error aani shuru ho jati he...... Any Solution for me ?
सरजी आप ग्रेट हो बहुत ही सुदंर मार्गदर्शन हुवा ये व्हिडिओ मे
धन्यावाद सरजी
Thanks Vishnu Ji for Support and encouragement.
Paaji main v ups install repair gulf mein karta hon.. Same to ups 15 kva 3/3 thik kiya tha... Sare problem menual padhny pata chal jata.. Model infosec ka tha,,, thank you sir ji for information,,
Thanks for Comments.
Good to know that, apko videos se help mil rhi hai.
@@gurjitprincesingh7932.. Yes sir help mill rahi hai.. Continue sir 👍
@@mdsarfaraj8339 Thanks
@@gurjitprincesingh7932 sir ye aap ki shop knha pr hai
Knowledgeable Hai Bahut Khoob sir
Thanks for Comment.
Thank ,s sir ji aap ne kafi knowledge di . Aap se kafi kuch सीखने ko mila .
Thanks for Watching and Writing,
Great .... Sir Ji
Thanks sir jee
Thanks sir
Sir thanks
Very nice sar ji
I have a problem i put the power wire in the ups but the screen not brighting but when i click on the power button its working and it’s give me error code (Ch) what to do in that case dear ?
good repair ups
Sir nice explanation ,
6kva ka ups ha thk chalta ha main py b or battery py b...backup b dy raha ha...matlb all ok ha ...lekin zyada dair chlta ha tu 02 error deta ha restart krain tu chala jata ha ...lekin permanent error ja ni raha ....pls guid
Same model hai or pls specify model
Very nice and informative video.........Thank you Sir
understand me in eng plz
Sir microtek ke sapeyer part milege kya
Mujhe batan wali PCB Chahiye h sir
Super
Output nahi araha he ji kya karenge
Check invertor section and DC to DC convertor Section
@@gurjitprincesingh7932 dada 41 folt solution
sir us model me riset mode nahi hai kya all difolt mod me kaise jaega
Bhaiyya namaskar.
Mujhe same no power/no ups aur screen turn on ki prob. Thi, power supply, dcdc module aur control teeno replace kiye parantu ups on hi nahi ho Raha hai. Power supply externally check kare to ok hai kick start ho Raha hai aur 12vdc bhi AA amrahi hai par ups on nahi ho Raha. Please help.
Sir microtek ups 3 kva with 6 batteries usme error show kr rha h BT aur light off hone pr output bnd kr deta h bilkul
Dear sir..
Hitachi company ka 36vdc,1kva ups hai...but main supply dene par automatically bypass ho jata hai sir so plz iska solution bataiye plzz
Bypass enabled hoga,
@@gurjitprincesingh7932 to sir plzz solution bataiye 🙏
Kindly create one video for Quarterly basis Preventive maintenance of 3kva 72voltdc microtek online ups.
Please confirm step by step
Sir mara Microtek 10kva online ups ha but usma some time ups ma vibration hota ha please help me
High Frequency model hai ya fir transformer based.
@@gurjitprincesingh7932 ha
@@electricallearner fan to jam nhi koi.
Microtek vs apc. Kiski life jyada hoti he aur quality kiski better hoti he?
Depends karta hai how you handle it or apne kis environment mein install Kiya hai, kis type ka load use kar rhe ho. Output Load is the most important thing... and input/output wiring.
@gurjitprincesingh7932 sir mera load high quality premium grade sound system he, iske equipment saare digital he aur bade expensive he, koi bhi tarah ka fluctuation ya spike inko damage kar dega, aur most important, supply me agar high frequency swtching noise present hoti he, to vo speaker me zyada sunai deti he. To output supply bilkul pure sine wave honi chahiye. Ab kya microtek ye kar lega? Kyunki apc thoda expensive hai, nahi to fir apc lena hi padega, please bataiye, thank you
@@burhanuddin127 yes apc is bit expensive but rugged. Microtek is all China based technology, Microtek imports products, as you describe about your expensive products so my opinion is go for APC. It's a one time investment.
Good bhaji
Sir mere pass v same ups hai, but kavi mains mey connection show karta hai kavi nahi jissey btry v charge nahi ho rahi.. Kya problem hai?
Nice video sir
Thanks Dear, Keep Watching and Sharing
sir if output voltage of ups higher then input as example input voltage 225V but online ups output voltage 240V ,no error shows in ups .? then what is problem in ups?
Code 3 raise when mains enter and output will be off . When mains cut then after switching off then buzzers will be stop and again switching on then ups will be started giving output 1 kva 36 volt online ups
It's PFC section not working, check input fuse and input related devices and tracks
Hi sir jee Mera ups Hitachi hirel ka hai ismein error code 01 a raha hai kaise pata Karen ki yeh problem battery ke bajah se hua hai yah main supply ke bajah ,kyun ki Naya ups lagaya tha sir please help me
Sir iska smps power supply module kese check karenge pls bataye mere ups me yahi problem battery connect karne par on nahi hota
Mera UPS main CH wali warning aarahi hai aur beep sound aaraha hai. Kya karna hoga please batayiye
Mera ups bhe CH ka error day rha kys msala ho skta
@@hassan007 avi tak pata nahin chala kaise fix karna hai. Microtek wale reply nahin de rahe.
Sir ji namaste, mera micro tek e2 series ka 1 kv online ups me 03 error code dekha raha hay our bypass mode display dekha raha hai.
Sir 2 Kva aplab 72 volt dc ka drive and control card kitne price mai melega
Sir ji mera 3kva consul neowatt ka ups hai sir usme error E4 aa raha hai plz help me sir
Hii bro thanks for the video.i have been getting beep sound and it displays 13∆ error. Pls let me know the solution.Thanks
Am using numeric company ups
@@MrVenkataprabhakar either batteries faulty or Inventor section
Sat saria kal pa ji 👋👋👋👋👋
Sat Shri akal Ji 🙏
Running me UPS Ko battery se disconnect kar sakte h sir
Risk hota, if batteries are in charging mode then high risk sprak ho sakta hai,
If batteries charged, but apko bahut shavdani see karna hoga.
Remember connector ya fir batteries wire ups se touch na ho
Sir Mera pass ek 10 kva microtek ka ups he
Jab charge karate he charge hota he magar 1hours ke bada charge karana Vanda karadeta te
Nice one
Thanks
Sir ji microtek 36v 1kv after mains on error code 27 what is the problem
Batteries Not Connected
@@gurjitprincesingh7932 same problem mujhe v hai sir, par pcb main battery volt thik dikha raha hain
@@susobhandas1298 jab ups mains mode mein on hotta hai, tab ek bar vo batteries mode mein shift ho Kar batteries chk karta hai, agar batteries support na Kare then it gives 27error.
jab ups mains mode mein on hotta hai, tab ek bar vo batteries mode mein shift ho Kar batteries chk karta hai, agar batteries support na Kare then it gives 27error.
Sir
Good morning
When and how does "soft start alarm" happen? What are the reasons?
How to solve soft start alarm?
What type of alarm You are asking about
what is ch error code, when it comes battery is not charging
my UPS show status CH error, I don't now fix it, pls help me :(
Charger section board complaint
error ee, what does it mean? microtrek 1kv 36v
Hello sirji,Good knowledgeable videos, keep it up sir ji...
Mujhe kuch doubts the ups related..can I have your whatsapp no.. please sirji....
Mujhe kuch madad mil.jayegi...
Mera ups Eaton 10 kva ka hai aur fault code 89 bata raha hai...kaun se sections pe problem hai....Aur kya kya check karna padega iska...
Kya aap iska..manual aur circuit diagram share kar sakte hain..please..
Awaiting for your kind response at the earliest..
Thanks..
🙏🙏
Hello sir 3kva online microtek ka ups hai 10 min chalne ke bad battery lo bata deta hai but battery indicator full rehta hai kya problem hai 75 ah ki sab new battery hai plz help
Batteries mode pe aisa karta hai ya fir mains mode pe.
Hello sirji... Mere pas luminous ka inverter hai.. But input nahi show kar raha... Kya problem aa rahi hai
@Gurjit prince singh Sir ji error code 04 on main mode.. iska Kya problem Hi kuch patanahi chal Raha hai ... please
Bus voltage balance nhi hai mains mode pe.
Input PFC distrubed.
Paji 5 kw ups mega pixel de 12 volts de 26ah de 15 battery replase karen wale last battery wire lagon te bade jor ke spark kyo kerde ah ji
Kyun k ups andar DC capacitors hunde ne, oh jado charge hunde ne te spark hunda.
Better ehi aa k ya te series ch blub lga k phela capacitors charge Kar lo. Ya fir phela input de k mains te on karke capacitors charge Kar lo fir batteries wali mcb on Kar lo
Paji mai battery wale negative wire te series te bulb laga ke usko discharge kerta hu jab tak bulb full chal ker band na ho jaye fer bhi spark kerta he ji
@@gurjitprincesingh7932 paji battery wali mcb band ker kai ve battery de wire jod sakde ne Ashe concter cg
Thank u sir j , for help us with this videos
Max series ki ups ki display battery fault and 27 error dikha rahahai, please help
27 error is due to: batteries connected nhi hai.
Ya fir batteries faulty hai
I have been getting beep sound and it displays CH error. Please let me know the solution
Cargador dañado
Chequea el cargador de baterías
Charger section board complaint
Sir etone e series dx 3 kva ups me f 01 fault aa rha esme kya fault ho skta hi
Sir mere ups me tp ki error a rahi hai over tempreture ki problems hai ye kaise solve hogi
What should we do when error code is 41. Over temperature. Please describe.
Sir mere pass ip11s- wn hitachi ka 1kv he pr usme charg amp or volt ka satting nhi he charg volt 41 volt he muje volt 40 v krne he koi upaye btaye
Hi brother I've been getting beep sound with EP error
Sir UPS on krte he isme Timer show krta hai ushka kya mtlb hai?
What is OC error?
Same microtek ups - error code 41 temperature. Any solution? 🙏
Check connection from controller to main card & programmable Card
Hello sir I have an online ups same model like this and I am getting error 41 can you please help what is the problem in my ups. After running 10 mints it's start beeping continuously with error 41
Temperature error hai, fan jam hoga ya slow chalta hoga ya fir fan faulty hoga chk it.
@@gurjitprincesingh7932 thanks sir ji helped it. i cleaned the fan and UPS it worked thank you.
@@rahulmehta2605 Welcome Dear.
@@gurjitprincesingh7932 hello sir ,i have same ups & same problam errer 41. we change fan . but ups create same problam
Bhai ye e square aur max plus series me kya difference hai
Our ups shows error code 27 & battery fault. Pls help how solve this
Buzzer awaz krta h or ❤️
triangle ( tribuz) wala sign ata h ... 3 kva Mikrotek.....kya problem h ? Service centre walo ke smz me nhi aaa rhi ...
Hello Sir I have an online ups same model like this and I am getting error 11 can you please help what is the problem in my ups ,problem occurred after changed batteries. after running 10 seconds it's start beeping continuously with error 11
Error 11 is for Invertor. It's mean invertor Section is not working.
Once Check controller connection and blower the UPS.
3 battery 1kva backup kitna time hota hai
Backup Batteries Amphere pe depend karta hai.
What is the error code 13 mean in mictotek
Sir kya main is par solar panel laga sakta hu
Sir, igbt drive ko kaise check kare, please uspe video banaye. New igbt replace karene ke baad drive ko kaise check kare.
41 ep pe pura video banaye
Sir kl hi battery replace Kiya to on tha bt aaj on nahi ho raha . Koi error code v nahi hai battery charge v ho rahi . B's on nahi ho raha plzzz solution bataye.
Power Supply Section Chk karo
Sirji 30 kva numeric ups me input h lekin output nahi deta h kya kare
sir 3kva online ups hai usme ep error de raha kya karu
सर नमस्कार मेरे पास माइक्रोटिक ऑनलाइन यूपीएस 3 केवीए का मशीन है इसमें 0 11 error code डिस्प्ले हो रहा है कृपया मदद करें धन्यवाद
Dear sir i got one techser 2kva 96vdc online ups. Itz not working with mains pls help
What problem you are facing at mains Mode.
Numeric 1 Kva Infiniti ups fault code 11 ( Softstart fail) iska video banaiye
sir microtac 2kv 72v smd bord main mains input relay on hoti hai our off ho jati hai bus v bhi banta hai batt.mode par chala jata hai mode par ok work
Check input fuse
main par bus volt 10% +ho jati hai our batt .charging bhi aati hai but 15second main input rilay cut ho jati hai
Hi sir.....mere ups me on karate hi sir beep baj raha he aur koi code nai dikha raha he sirf error ka sign he...
Luminus ka 3k main CH error or beep a rahi h kya folt h
Sir mere 3 KVA Microtech Max UPS me.. Battery Full charge hone par, Battery Mode par aa jata he.... aur Battery error aani shuru ho jati he...... Any Solution for me ?
Ya toh batteries faulty hai,
Ya fir loose connection in batteries.
Ya fir input voltage low hoga
11 error code आ रहा है, ठीक करने में कितना खर्च आएगा
Bro Hitachi ups 1000v 01 code if any solution please help me
Sir Eaton Ups ka DC to DC nahi banri hy
Uske andar dctodc card transistor ka hy to ic wala laga skte hy ky
Yes aap lga sakte hai.
my UPS is also showing error 41 every time after working for 15-20 mins.... .sir could you please help me how to solve
It's temperature error.
Fans are not working properly or a loose connection from controller side.
Lastly thermistor might be reason of your problem
Thank you very much sir.... I will check and will update
@@Sidhu.Kuldeep Sure
@@Sidhu.Kuldeep ho gya ups theek
No sir still not solved... I opened the ups and checked the fan was working fine... Tell me how to resolve the issue
sir isme 10 number fault code kya hai dalo microtek ka niche battery ka logo aur upar number ate hai
My crts 3kva ups mai condenser fat gaya hai kis vajhse
Dami
🙏🙏 gutu ji error code 13 ka falt kya hai bata dijiye
microtek 1kv ups me 03 fault aa raha he. solution bataye. sir .
Mujhe EP error mil raha hai mere microtek online ups mein kya issue hoga. Help please
Control card se connection check karo, loose toh nhi hai
Sir if occurred 41 than what is error plz reply 1 kva microtek online ups
temperature senser fault
02 fult code kya he
Bus voltage not proper
Compact ups fault code 62. what is the problem bro...?
Sir prostar 3kva online ups me 62 error aa raha Krupa batye kahe Ka h
sir mera ups ban ho jata hai light jane ke baad ya fir power botton band karne ke baad plz help sir
Kitni batteries lagi hai ??
@@gurjitprincesingh7932 3 batteries hai
1kv ka online ups hai sir
@@azeemshaikh7241 agar batteries almost 3 year old hai toh weak hone ki vajha se backup nhi de pa rhi hongi.
sir batteries 3 year old hai but maine check kiya full charge hai..
My ups problem is error 01
Please solve the problem
Hi Anna What is 41 alert and tp alert in online ups what is problem.
What the solving if tp error
error 41 is for heat error check Fan of UPS
Aapka ki shop ka addreas kya hai
Sir mera Delta ka online UPS hai MODEL NO.. UPA302NX2000BOBO MODEL DESCRIPTION: INX-3K bt input nahi dikha raha.. Charging nahi ho raha
On line ups 1kva luminous error code 02
Bus voltage high , check feedback resistance dc dc Module chip. Also change controller Card
Sir I am getting 03 error when I am connecting the input please help sir 🙏
Same problem
Mere pas sem model hai lekin on hokar off ho jata hai plij help me sar