Heat Shrink Cable Termination Outdoor (HV) - 11kV 33kV 3 Core XLPE BS6622 Cables

แชร์
ฝัง
  • เผยแพร่เมื่อ 13 พ.ค. 2014
  • THORNE & DERRICK INTERNATIONAL | SHRINK POLYMER SYSTEMS UK MAIN STOCKISTS
    Contact us for Competitive Prices & Fast Delivery from Stocks
    To See The Full Shrink Polymer Systems Range That T&D Offer Click Here -
    www.powerandcables.com/manufa...
    SPS 11kV cable terminations are available to terminate HV high voltage single core and 3 core XLPE, EPR and PILC cables in outdoor installations (pole-mounted) - the video features the installation of a 3 core heat shrink outdoor (rain-shed type) cable termination for use with XLPE cables.
    To See The Full Range Of High Voltage Cable Joints, Terminations & Connectors Click Here -
    www.powerandcables.com/produc...
    This 11kV cable jointer training video features use of the outdoor armour earth kit used to effectively cable gland, terminate and earth the wire amours on either single core cable (AWA) and 3 core cable (SWA).
    Heat shrink outdoor cable terminations are also available for 3.3Kv, 6.6kV, 11kV, 15kV and 33kV cables. The bracket and stand-off insulators shown are also available. Heat shrink cable terminations with longer tail lengths can be supplied. We also show the use of cable jointers tools to remove the semi-conductive screen to produce a reliable cable termination.
    SPS Heat Shrink Cable Joints & Cable Terminations - Quality Performance Testing : Shrink Polymer Systems heat shrink cable joints and cable termination kits are tested to BS7888 which incorporates Cenelec Standards HD 628 S1 and 629.1 S2 : 2006, DIN VDE0279 and IEC60502.
    BLOGS | Cable Joints & Terminations
    High Voltage Cable Joints
    www.powerandcables.com/highvo...
    Some Thoughts On MV HV Heat Shrink Cable Joints & Cable Terminations
    www.powerandcables.com/heat-s...
    MV Cable Accessory Technologies | Heat Shrink, Cold Shrink & Push-on
    www.powerandcables.com/mv-cab...
    Connecting High Voltages & Energising Data Centres
    www.powerandcables.com/data-c...
    Joints & Terminations for Network Rail 25kV Electrification Projects
    www.powerandcables.com/joints...
    THORNE & DERRICK INTERNATIONAL
    Thorne & Derrick International are specialist distributors of LV, MV & HV Cable Installation, Jointing, Duct Sealing, Substation & Electrical Equipment - servicing UK and global businesses involved in cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV, 66kV and EHV.
    Stocking & Supplying Duct Seals | Cable Cleats | Cable Glands | Electrical Safety | Arc Flash Protection | Cable Jointing Tools | Cable Pulling | Earthing | Feeder Pillars | Cable Joints LV | Joints & Terminations MV HV | UK & Export Sales
    Phone: +44 (0)191 410 4292
    Email: uksales@thorneandderrick.co.uk
    www.powerandcables.com/
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 31

  • @ig_foobar
    @ig_foobar 3 ปีที่แล้ว +4

    This dude is a pro. His workmanship shows that he's done a lot of these.

    • @simonmaverick9201
      @simonmaverick9201 3 ปีที่แล้ว +1

      Absolutely, his diligence and workmanship are very impressive. I want him doing all my HV post terminations!!

  • @NmEntertainment-dw3ig
    @NmEntertainment-dw3ig 5 ปีที่แล้ว +4

    I'm impressed

  • @muhammedkabeerkabeercochin3639
    @muhammedkabeerkabeercochin3639 3 ปีที่แล้ว

    Great wonderful episode

  • @simonmaverick9201
    @simonmaverick9201 3 ปีที่แล้ว +1

    Just downloaded this company catalog - have a look guy's, great range of polymeric shrink insulation kit upto 33kv.

  • @RASHID5100
    @RASHID5100 5 ปีที่แล้ว

    its owesome..

  • @NmEntertainment-dw3ig
    @NmEntertainment-dw3ig 5 ปีที่แล้ว +1

    Very nice

  • @zahidsaleem7465
    @zahidsaleem7465 5 ปีที่แล้ว +1

    Nice job done
    Not easy on feeld. ....

  • @ebrahimsaad4042
    @ebrahimsaad4042 หลายเดือนก่อน

    فيديو رائع

  • @maazahmad1631
    @maazahmad1631 4 ปีที่แล้ว

    Interesting.....

  • @startonengineering7343
    @startonengineering7343 2 ปีที่แล้ว

    Some one help me what if the semi conductor screen in not removed?

  • @AliMohammed-iv2dz
    @AliMohammed-iv2dz 2 ปีที่แล้ว

    Cable clangs 20 and termination

  • @manni02
    @manni02 4 ปีที่แล้ว

    What will happen if the length of anti tracking tube is reduced at site due to constraint of terminal box dimension.. assume supplied length of anti tracking tube is 500mm and we reduced it at site to 450mm

  • @ernestopobladormosquera6336
    @ernestopobladormosquera6336 ปีที่แล้ว

    I need a question test. Examanation and answer......in Aramco splicer certificate...if pass practical test.

  • @nadeertp9
    @nadeertp9 4 ปีที่แล้ว +1

    Where can i buy the semiconductor removing tool?

  • @omegalpha28
    @omegalpha28 3 ปีที่แล้ว

    Maybe a stupid question but what do you mean when you " don't use glass"

    • @_AvaGlass
      @_AvaGlass 3 ปีที่แล้ว +1

      I found this PDF that mentions not using a shard of glass. I'm not sure why someone would think to use a shard of glass instead of just using a metal knife, though. Maybe because it's not conducive.
      www.ensto.com/globalassets/brochures/underground-cable-networks/europacable-position-paper-best-practices-for-installation-of-medium-voltage-cable-accessories.pdf

    • @nh2805
      @nh2805 3 ปีที่แล้ว +1

      @@_AvaGlass I didnt listen to the audio on this but watched this craftsman at his work...I think what he would have meant is when carrying out the semi conductive horizontal cut do not use glass, it is a widely used method in high voltage cable jointing.the jointer usually smooths the transition from semi con to the insulation with a shard of glass,almost planing it meticulously making sure there is no bumps that could lead to a hot spot or stress point..nowadays we are not allowed to use knifes for a lot of these cuts.we have various cutting, stripping tools for the job. but you can't beat the skill this man has.

  • @aiyubthanksforexplanationc4046
    @aiyubthanksforexplanationc4046 3 ปีที่แล้ว

    There is a kind of termination
    But Earthing braid hose clips should be in the break out
    But there is a looking is very ugly LMK

  • @Game-cr8pg
    @Game-cr8pg 2 ปีที่แล้ว

    LBSNS XM TMOS

  • @mohanji5530
    @mohanji5530 5 ปีที่แล้ว

    I want to perches this cutting tool help me

  • @yousufdoharey2529
    @yousufdoharey2529 4 ปีที่แล้ว

    Battery

  • @muhammadjunaid6331
    @muhammadjunaid6331 2 ปีที่แล้ว

    Hh

  • @baldevsinghbhullar29
    @baldevsinghbhullar29 6 ปีที่แล้ว

    Cable joint in hindi pl

  • @gopigopi5765
    @gopigopi5765 3 ปีที่แล้ว

    Hi
    Sir speak in Tamil please

  • @jagdishmloya
    @jagdishmloya 5 ปีที่แล้ว +2

    Nicely explained. But the voice if it is in Indian accent, it would be better to understand.