Day 5 Session 11 QC GCMS Gas Chromatography Mass Spectrometry

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ก.พ. 2013
  • Excerpts from the session on Quality Control and Analysis of perfume.
    Introduction to QC GCMS Gas Chromatography-Mass Spectrometry. A method of separating and analysing perfume, flavours and volatile mixtures for quality control, research and 'matching'.
    The Art & Technology of Perfumery Workshop March 2012.
    Lecturer: Stephen V. Dowthwaite, PerfumersWorld with students who have traveled to Bangkok for the course from UK, Oman, Indonesia, France, Singapore, New Zealand, India, Poland, Japan, South Africa, Australia and USA.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 34

  • @PerfumersWorld
    @PerfumersWorld  ปีที่แล้ว +1

    An essential difference since this talk was given over 11 years ago is that now generally Mass Spectrometers use Quadrupole detectors where after the gas molecule with material enters the MS from the GC column and passes over a filament that fragments the molecules, knocking off electrons and producing a charge, the m/z or mass to charge ratio, on each fragment. The charge allows the fragments to be drawn into an electromagnetic field between 4 electromagnetic poles. The charges on the poles cycle through settings that allow only 1 fragment type based on is m/z ratio to traverse the path and hit the detector which counts and calculates each fragment's mass and relative abundance to all the fragments of the whole molecule as the detector cycles through a range of molecular sizes over and over again at lightening speed. The Spectra is then compared to a several hundred thousand Spectra of chemicals in a database and the closest matches with their probability listed.

  • @carly1459
    @carly1459 11 ปีที่แล้ว +2

    Wish I had him as an instructor back when I was training on GC/MS. Very thorough...

  • @MsMPil
    @MsMPil 11 ปีที่แล้ว +1

    Excellent information. Thanks for posting the whole serie of videos!

  • @Perfumax
    @Perfumax 11 ปีที่แล้ว +1

    Thank you for posting. It cleared up a lot of confusion.

  • @Perfumax
    @Perfumax 11 ปีที่แล้ว

    Thank you for posting. This really cleared up a lot of confusion.

  • @milusiowa
    @milusiowa 8 ปีที่แล้ว

    GCMS-QP2010 seriesERROR DISPLAYS
    "[0d97] Low Vaccum ERROR. Chesk for vaccum Leak."
    I replaced: o-ring,septum, liner.
    Vacuum control in I can not turn on the ion source AVAILABLE FUNCTION "on"
    how the MS remove the source of ions? I can not open the door to MS (probably sucked into).PLEASE HELP AND Thanks for advance!

  • @kelwinstorek8000
    @kelwinstorek8000 11 ปีที่แล้ว

    Great training fo all.

  • @ehabhassan2663
    @ehabhassan2663 10 ปีที่แล้ว +2

    it is nice presenration

  • @cgman173
    @cgman173 9 ปีที่แล้ว

    yeah, he was prepared

  • @raj9324
    @raj9324 4 ปีที่แล้ว

    Sir in GCMS all molecules get in seperate form so how can i get the perfume Formulations?
    Or is it easier to get formulation in only GC FID?

  • @AntheaHenton
    @AntheaHenton 10 ปีที่แล้ว +2

    Very nicely and simply explained. Thankyou

  • @osiris1309
    @osiris1309 10 ปีที่แล้ว +1

    Hello, I am interested in the GCMS analysis of perfumes. Do you plan to conduct this workshop again?? If so, when?

    • @thingando8044
      @thingando8044 7 ปีที่แล้ว

      Do you know retention index???. if you know, please you can contact with me . please. Facebook. Đỗ Ngân.

    • @shreejeethrd1136
      @shreejeethrd1136 3 ปีที่แล้ว

      how did u learn then?

  • @sencrypto7708
    @sencrypto7708 11 ปีที่แล้ว +1

    GOOD INFORMATION.

  • @tanweersyed1140
    @tanweersyed1140 10 ปีที่แล้ว +1

    Thank you very much Its really help full

  • @williammoura4146
    @williammoura4146 11 ปีที่แล้ว

    Legends please!

  • @salice5409
    @salice5409 11 ปีที่แล้ว

    can't download ,why?

  • @shavezali7338
    @shavezali7338 7 ปีที่แล้ว

    Hello, I am interested in the GC.MS analysis of perfumes. Do you plan to conduct this workshop again?? If so, when?
    REPLY

    • @shreejeethrd1136
      @shreejeethrd1136 3 ปีที่แล้ว

      how did u learn then?

    • @PerfumersWorld
      @PerfumersWorld  ปีที่แล้ว +1

      @@shreejeethrd1136 Please check the website for workshops

  • @shreeflavour1
    @shreeflavour1 5 ปีที่แล้ว

    how much sample required GC analysis

    • @PerfumersWorld
      @PerfumersWorld  ปีที่แล้ว

      A fraction of 1 gram, a wet smelling strip or even just the headspace above a sample but for convenience 1 - 5 grams is generally better.

  • @Junki786
    @Junki786 10 ปีที่แล้ว +2

    n the teacher got dam brilliant

  • @Prometheus4096
    @Prometheus4096 9 ปีที่แล้ว

    What does it mean that mass spec doesn't mean anything without a computer? With all these simple molecules, a lot can be learned from just looking at the mass spec data and figuring it out yourself. No need to have a computer compare it to a database.

    • @gdm0485
      @gdm0485 8 ปีที่แล้ว

      +Prometheus4096 not all molecules are simple

    • @Prometheus4096
      @Prometheus4096 8 ปีที่แล้ว

      +gdm0485
      Doesn't really matter. If you have a pure sample of some unknown and you use both MS and NMR, you can know what it is even if it is a big molecule.
      What they guy is saying is just wrong.
      Now if you have a complex mixture of 200 unknowns, very similar and big molecules, that is different.

    • @Ume71
      @Ume71 4 ปีที่แล้ว +1

      nice introduction about the GC & GCMS

  • @TheeMelloMan
    @TheeMelloMan 6 ปีที่แล้ว

    Not interested in perfume at all but this was some good info