जाधव सर मैने इसके बारेमे एक फोरेनर का व्हिडीओ देखा था उसने सिंगल मेमरन, डबल मेमरन प्यारलल और डबल मेमरन सिरिज का बहुत ही अच्छा कम्प्यारीजन करके डबल मेमरन सिरीज configuration को सजेस्ट किया था! आपका व्हिडीओ भी मुजे बहुत पसंद आया. Thanks for useful information!
Please post a video for people who already have branded uv uf systems with bad water taste . How can any one improve the water taste by fitting any other filters to existing uv uf machines for taste improvement.
Sir flow water tds is 1500 and after passing 1st membrane waste water tds is 1800 tds so 2nd membrane 1800 tds pass out membrane life is sure effects and chock
Sir Apne pehli mebrin ka Dren Ko new membrin k in me Laga Dia Kia is se tds Kam ho paega Kia pump par lod nahi padega Kia membrin jaldi khrab nahi hogi
There is a very big technical fault in this whole arrangement i.e.: 1) No reference to any measurement of output water TDS which is the most essential part and function of any reverse osmosis system. This person should have taken the TDS readings at all levels like: a) input water b) first membrane waste water output c) first membrane purified water output individually TDS d) second membrane individual TDS (e) both membranes combined TDS. In reality what is happening is (a) you have to upgrade your pump to a higher capacity because the existing pump will not be able to sustain for long due to increased load of 2 membranes, as the pressure from the pump is pushing raw water through the RO membrane. (b) The waste water with higher TDS [ varying from 5 to 20% depending upon the rejection rate of the first membrane] from first membrane becomes the raw input for second membrane resulting into a higher TDS of consumable water.
True TDS will be higher, because there is no osmotic pressure on the second RO chamber so i doubt any reverse osmosis taking place, pump would not get weak as it is only connected to the first chamber, it is actually acts like TDS adjuster, as second chamber will add TDS to pure water.
Dono membrane series me hai first membrane ka reject water second membrane me gaya hai to presure dono par equal padega to ek hi fr ki zarurat hai yha.
Mere customer Hai unko mene 3 months pahile pentiar ka membrane dal ke Diya Tha par aabhi uska speed Kam ho gaya Hai Kal unko ye system Mai upgrade karva Deta hu Sirf bataye 2nd membrane ki life kaise rahegi ye case Mai ye system Mai unka TDS 600 hai
Sir pressure sahi tha Muze aap ye bataye aapka jo ye design hai usmai 2nd jo membrane hai uski life kam rahegi ya 1 year aaram se work karega TDS 600 hai
Very good model sir...but sir I have some questions..1) iss model me 1st membrane ko effect toh nahi hoga kyun ki usme FR nahi laga hua Hai...2) product water ka tds kitna Hai sir.
Very nice explanation, 1) Please upload full assemble R O plant of 50 lph & 100 LPH plant, SS skid. 2) Can you draw wiring diagram of domestic R o plant & 50 LPH r o plant. 3) how to connect SMPS, SV & Pump & float switch? explain in detail. thanks.
hlo sir aap Jo material lagta hay us ki price vice list bana kar koi video dall sakte hay. jis se hamme ashe brand k material or rate ke knowledge ho Jane.
जाधव सर मैने इसके बारेमे एक फोरेनर का व्हिडीओ देखा था उसने सिंगल मेमरन, डबल मेमरन प्यारलल और डबल मेमरन सिरिज का बहुत ही अच्छा कम्प्यारीजन करके डबल मेमरन सिरीज configuration को सजेस्ट किया था! आपका व्हिडीओ भी मुजे बहुत पसंद आया. Thanks for useful information!
+Sunil Patil thanq bro
Good information from multan Pakistan say tariq khan ❤
Please post a video for people who already have branded uv uf systems with bad water taste . How can any one improve the water taste by fitting any other filters to existing uv uf machines for taste improvement.
Sir flow water tds is 1500 and after passing 1st membrane waste water tds is 1800 tds so 2nd membrane 1800 tds pass out membrane life is sure effects and chock
150 चा पंप आहे...आणि 75+75 दोन मेम्बरण आहेत...connection कसे कराचे...दोन मेम्बरन्स चे..FR कितीचा लावाचा..
Sir
80 gpd + 80 gpd membrane in series use karne k liye pump 150 gpd ka use karna hoga ky??
Sir Apne pehli mebrin ka Dren Ko new membrin k in me Laga Dia Kia is se tds Kam ho paega Kia pump par lod nahi padega Kia membrin jaldi khrab nahi hogi
Nhi , hogi .. ok h
hi sir 3500 TDS ke kiye kiss tarah ka system banega please suggest
BW RO MEMBRANE
दूसरी मेम्ब्रेन जल्दी खराब होगी और इसके लिए पंप भी 100 या 150 GPD का यूज़ करना पड़ेगा
There is a very big technical fault in this whole arrangement i.e.: 1) No reference to any measurement of output water TDS which is the most essential part and function of any reverse osmosis system. This person should have taken the TDS readings at all levels like: a) input water b) first membrane waste water output c) first membrane purified water output individually TDS d) second membrane individual TDS (e) both membranes combined TDS.
In reality what is happening is (a) you have to upgrade your pump to a higher capacity because the existing pump will not be able to sustain for long due to increased load of 2 membranes, as the pressure from the pump is pushing raw water through the RO membrane. (b) The waste water with higher TDS [ varying from 5 to 20% depending upon the rejection rate of the first membrane] from first membrane becomes the raw input for second membrane resulting into a higher TDS of consumable water.
True TDS will be higher, because there is no osmotic pressure on the second RO chamber so i doubt any reverse osmosis taking place, pump would not get weak as it is only connected to the first chamber, it is actually acts like TDS adjuster, as second chamber will add TDS to pure water.
Sir ,do we also need to upgrade the ro pump ???
sir Kya buster pump ka head kharab hone se tank bharne me time lagta hai...
ha. pressure reduce ho jata h..
sir to dual membrane use karne se ph or alkline filter badhane ki jarurat padegi kya plz suggest mi
+Ankit Motghare yes
Achha hai but tds kam hoga ya jyada
bro !
aapne first membrane me F.R nhi lagaya isse first membrane ki life par effect nhi padega ?
Dono membrane series me hai first membrane ka reject water second membrane me gaya hai to presure dono par equal padega to ek hi fr ki zarurat hai yha.
We need to keep the both membranes in parallel and need to change flow ristrictor
Sir 2nd membrane ki life Kam hogi shayad ya aaram se 1 year wrk karega
Or TDS controller Use kar sakte Hai na ismai
Mere customer Hai unko mene 3 months pahile pentiar ka membrane dal ke Diya Tha par aabhi uska speed Kam ho gaya Hai Kal unko ye system Mai upgrade karva Deta hu Sirf bataye 2nd membrane ki life kaise rahegi ye case Mai ye system Mai unka TDS 600 hai
+rohan deshpande bro check his pump pressure. By pressure guage . Pentair needa 60 psi
Sir pressure sahi tha
Muze aap ye bataye aapka jo ye design hai usmai 2nd jo membrane hai uski life kam rahegi ya 1 year aaram se work karega TDS 600 hai
please sir batyea Tds single membbren pr kya tha series pr kitna aayega
sir ye 2nd time ka water utna hin purified hoga yaa nahi
Sahi hai par flow restrictor same lagaya hai to chalega?
Translater plan ke andar Express energy ka upyog kaise karte hain please help me
Very good model sir...but sir I have some questions..1) iss model me 1st membrane ko effect toh nahi hoga kyun ki usme FR nahi laga hua Hai...2) product water ka tds kitna Hai sir.
+ram naslai 1.no effect. 2. TDS will be very low compared to single memberane
100 gpd pump ka pressure kitne hona chahiye
Thanxx broooo.... Very good idea and grt job
Very nice explanation,
1) Please upload full assemble R O plant of 50 lph & 100 LPH plant, SS skid.
2) Can you draw wiring diagram of domestic R o plant & 50 LPH r o plant.
3) how to connect SMPS, SV & Pump & float switch? explain in detail.
thanks.
sir. i will shurely post it.. thankyou.
thanks dost. Please tell me your name and email id. So if i have any doubt, I can ask on mail id.
you can ask me anytime here in comments.. no problems
thanks
Which is best membrane & Pump and SMPS for 50 ltr plant?
Namstha ji him kese select karege membrane brand and tds level
What is the rating of booster pump?
Flow restrictor kitne CC ka hai please reply sir
sar TDS to aapne btaya nhi ke kitna aatahe sar or kya ham pump me se Dono Haughing me nhi desakte saplai
+Natraj Mudliyar ok.wait i will make a continuous video ..as flushing was needed bfore checking tds
+Natraj Mudliyar i will make anothet vedio .as flushing was needed. Bfore tds check
see the continuation video
very helpfull 🙏🙏🙏
Thanks
Very helpful reviews 👍
when we are using two membrane what is the necessity of tds control valve
+Ravindra Deshpande it is optional
dual membren wala system ke liye pump konsa chahiye
same motor. if using in series...
Sir inlet water and finally product water ka tds bhi bataiye. Please.
pump 150gpd ka use karna hoga.nhi to pressure same rahega
Can work 80gpd two membrane on 100gpd pump?
Pump kitne gpd ka he
hlo sir aap Jo material lagta hay us ki price vice list bana kar koi video dall sakte hay.
jis se hamme ashe brand k material or rate ke knowledge ho Jane.
+Rashpal Singh sorry friend. Cant put price on youtube
Great sir
Pump same raheja kya?
Membrane kitne life tak chelta hee
1-2 yrs
sir esmian Fr 5oo ,45o ya 350 kounsa Lagana hie.
550
450 koi sa bhi laga lo bhai
Aur pump ku koi effect ni hota kya
+Syed Iqbal nai
Sir ek pump se do membrane work kregi kya
No problem
अगर sv डाला नही तो बंद मे भी पाणि आता है सर .
Sir Isse tds kitna hoga
Speed increase but
Water quality increase or previce quality give.
+Shaiik Riyaz quality increase. Tds reduces more
Very good video
Dusre membrane bahut jaldi kharab ho jayegi
pump produce pressure 1st membrane if we add another membrane pressure is reduce.
pressure. tds.also check in new video
+Raju Burhade ok I will make a video
ser is me Membren Bolak nhi hoga kya?
nahi hoga
great ...👍👍👍
sir pump kitne gpd ka he
+jaypal khandre pump 75 ka hi hain
pump is 75 gpd .but my smps is of 36v
2500tds PR work krega system
yes ,karega
Sir pump 80 gdp ka hai
Sir FR kitne ka lagega
Tds kina
Pls sir 100 liter per hur video banao pls
Can u show tds level
Good way
Sir thnx
Sir this is very bad aapne membrane ka naam nhi dikhaya aur membrane housing ka naam bhi nhi btaya 😏😏😏
kashif javed
pakistan
Sir is ka Tds change hota ya same ata hai
+Syed Iqbal tds kam hota h bhot