Commercial Building Design by using STAAD Pro V8i software

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ต.ค. 2024
  • In this Video lecture you are able to learn about Analysis and Designing of Commercial G+3 Story Building by using STAAD Pro V8i Software.
    -----------------------------------------------------------------------------------------------------------
    In this channel you can learn about online civil engineering softwares. So Please subscribe my channel for more intresting videos.
    -----------------------------------------------------------------------------------------------------------
    To subscribe my channel click on Red Button and also press the Bell icon.
    -----------------------------------------------------------------------------------------------------------
    Building properties
    1. Number of stories G+3 story building ------------------------4 no’s
    2. Number of portions----------------------------------14X3=42 Portions
    3. Beam size-----------0.3mX0.3m
    4. Column size--------0.4mX0.4m
    5. Slab Size------------0.15m
    6. Loads
    Dead load
    Self weight,
    Beam dead load 0.3X0.3X25 ---------2.25Kn/m
    Column dead load 0.4X0.4X25----------4Kn/m
    Slab dead load 0.15X25--------------3.75kN/m2
    Live load 5 kN/m2.

ความคิดเห็น • 23

  • @md.mahinulislam2510
    @md.mahinulislam2510 2 ปีที่แล้ว

    Helpfull tutorial

  • @souravacharya967
    @souravacharya967 4 ปีที่แล้ว

    Thanks For the Nice Design Great To Learn

  • @civil_boy_-ym1wz
    @civil_boy_-ym1wz 2 หลายเดือนก่อน +1

    THANK YOU VERY MUCH SIR JI

  • @souravacharya967
    @souravacharya967 4 ปีที่แล้ว

    I have one question about wall load does it coming under dead load. How we can put in to this design?

  • @trendsetter5115
    @trendsetter5115 4 ปีที่แล้ว +1

    Beam detailing...show it in one vedio for a one in all structure

  • @rashmiverma5850
    @rashmiverma5850 3 ปีที่แล้ว

    Sir please industrial building par bhi bna dijiye basement parking ground +3 load basmati to parking 50 ton and other floor 30 ton ke hisab se krni h please sir btaiye ispar kon kon se load apply honge

  • @manisingla3860
    @manisingla3860 5 ปีที่แล้ว

    sir downloading m no audio show hora h apki video m,, kya problem ho skti h

  • @venkateswarishunmugam
    @venkateswarishunmugam 3 ปีที่แล้ว

    we you didn't give load combinations?

  • @thulasideva4273
    @thulasideva4273 3 ปีที่แล้ว

    Can we save the reinforcement detail diagram into autocad from staadpro

  • @omgomase84
    @omgomase84 4 ปีที่แล้ว

    What about Earthquake and wind analysis

  • @b.malleshyadav3075
    @b.malleshyadav3075 4 ปีที่แล้ว

    In this you have given dead load additionally bcz already it's calculated dl.. during selecting the selfweight and one more thing you didn't apply stair case load.

    • @KarthikSGK
      @KarthikSGK 3 ปีที่แล้ว

      Yes...and there is no wall load...

  • @eduhub6317
    @eduhub6317 5 ปีที่แล้ว +1

    Without wall load without staircase how can you design???

  • @priyankaYadav-db9bn
    @priyankaYadav-db9bn 3 ปีที่แล้ว

    Sir foundation design nhi ho rha hai please help 🙏

  • @mdirshadalam5825
    @mdirshadalam5825 3 ปีที่แล้ว

    why have you not design the SLAB IN this video

  • @HimanshuYADAV-br7eq
    @HimanshuYADAV-br7eq 5 ปีที่แล้ว +1

    Column load kyun daale bhai ?....galat bata rhe ho

    • @civilengineeringbyshravan9596
      @civilengineeringbyshravan9596  5 ปีที่แล้ว

      As per u r question we need to calculate dead load of column by using column cross section and unit weight of concrete

    • @civilengineeringbyshravan9596
      @civilengineeringbyshravan9596  5 ปีที่แล้ว

      By using STAAD Pro V8i software no need to calculate dead load separately if u give self weight in y direction it will directly calculate the dead load for beams columns and slabs

    • @gowthamiv4841
      @gowthamiv4841 4 ปีที่แล้ว

      @@civilengineeringbyshravan9596 if we unkownly assigned the dead load means does it take additionally..
      In this videos you have selected the unwanted nodes to elliminate but you are showing the lower floor fully covered slab and first floor having open to sky???????

    • @mdirshadalam5825
      @mdirshadalam5825 3 ปีที่แล้ว

      @@civilengineeringbyshravan9596 sir if i want to add the load of wall and floor finish then i should ad or not