Diode : FR107 1A/1000V
Varistor : 10D471K
Hello, i have the same charger, and the big transformer has a burn on the side. Do you know the specs of the transformer so i could try get a new one, thanks
dont have to change the diode since it is part of the secondary voltage circuit which would not be affected by the input voltage change given that the transformer primary winding
Bro, I accidentally plugged in my charger to 230V outlet. The charger discharge a liquid. Im currently residing here in Saudi. Can this be still repaired?
how long did it stayed plugged?
@@siredwarddimaguila one hour.
I had it fixed already.
@@virtualspanner how it is fixed?
@@ahmadfirdausbinyahaya8063 I had the capacitor replaced.
يعطيك العافية. لو وصلته ب240 فولت مباشرة والان ما عم يشحن. ايش القطعة الي لازم تتبدل عشان يرجع يشتغل؟
اول قطعه راح تتاثر فيروستار
varistor
ولاكن هذا شي مبدئي ف من الممكن تتبعها مكونات اخرى يجب الفحص الجهاز كامل و مشاهدة اذا كان توجد قطعه محترقة
I have the same problem.
@@muharraqi55 I checked mine and there was no burnt components, only small amount of liquid on the side of the circuit board.
@@muharraqi55 انا صارت لي نفس مشكلته ولا حصلت حد يفحصه تعرف محل يعدله او ارسله له تعدله لي وبحقه طبعاَ
اذا انت من البحرين ، اقدر اجوفه لك و بدون مقابل
Just get varistor 14d431k. Will it work?
Yes it can work
@@muharraqi55 thank you
CAN VARISTOR NUMBER TRV 10511 WORK
I have done replacing those what you have done but the main fuse keeps on blowing..
But the rapid charger has a jumper already that you can cut then its easily converted to 220V no need to replace the varistor its already 270volts
it was so good
مرحبا اخي
ما هو رقم الديودا الجديده الذي لحمتها مكان الاصلية؟
مرحبتين
Diode : FR107 1A/1000V
Varistor : 10D471K
وشكرا على الاهتمام
Why replace D2 FR107?
No need to replace diode , just replace the varistor
Can someone explain to me why he did cut the line?
how much size diode
how much size fuse
Main fuse has to change to 240v and half of the current rate if you don't want your house burnt.
yes i have changed that before to ( 1.5amp fuse ) to my plug uk , because it is drawing 0.6amp when it's charging
anyway i don't have any problem and it's still working great