How to control valve calibration and maintenance

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ก.ย. 2024
  • CONTROL VALVE POSITIONER WORKING PRINCIPLE
    #controlvalve #controlvalvecalibration #controlvalveparts
    A valve Positioner is a device used to increase or decrease the air load pressure driving the actuator until the valve’s stem reaches a “POSITION” balanced to the output SIGNAL from the process variable instrument controller.
    Valve positioners are used on controlling valves where accurate and rapid control is required without error or hysterises.
    Positioners are generally mounted on the side-yoke or top casing of the pneumatic actuator for linear sliding stem control valves, and at/near the end-of-shaft for rotary control vales. For either basic design type, “mechanical feedback linkage” connected directly to the valve’s stem provides feedback to controller. The process controller tells the positioner to “change” position; the feedback linkage reports back to the positioner confirming that a change has occurred and gives a “sense” of the magnitude of the change in position.

ความคิดเห็น • 15

  • @Mindsoul2022
    @Mindsoul2022 3 ปีที่แล้ว +2

    Nice content, thanks for sharing.

  • @iqbal-hc9te
    @iqbal-hc9te 10 หลายเดือนก่อน +1

    All information is good.
    But I need main function in written.
    Please write it only main function.
    Thanks

  • @mdmerajshekhe6932
    @mdmerajshekhe6932 3 ปีที่แล้ว

    Bahut badhya sir isi tarah ka video banaiye

  • @RamBabu-ev9wl
    @RamBabu-ev9wl ปีที่แล้ว +1

    👌

  • @mdsalik1289
    @mdsalik1289 3 ปีที่แล้ว +1

    Very very nice👍

  • @secretworld7938
    @secretworld7938 9 หลายเดือนก่อน +1

    Sir calibration kr ke dikhaiye please with the adjustment of zero and spane setting

  • @sivakumarselvarasu3814
    @sivakumarselvarasu3814 3 ปีที่แล้ว +1

    Nice

  • @reycantor7398
    @reycantor7398 2 ปีที่แล้ว +1

    provide an english subtitle sir..and it will be very good toturial.
    Thank u

  • @farooqrather5637
    @farooqrather5637 7 หลายเดือนก่อน +1

    R/s my actuator does not got close 100℅ on 20mamp what is the problem from actuator valve or need caliberation

  • @sonukumarsahani8001
    @sonukumarsahani8001 3 ปีที่แล้ว +1

    Nice sir but esi positioner ka calibration ka video bhi banayiye sir

  • @sanjivgurjar261
    @sanjivgurjar261 3 หลายเดือนก่อน +1

    Wire ke canntion bar me janakari dene hey

  • @nirmalbishnoi3266
    @nirmalbishnoi3266 ปีที่แล้ว +1

    LCV agar 60% se jyada open nhi ho rha h to kya krenge

  • @avijitmalakar6596
    @avijitmalakar6596 ปีที่แล้ว +1

    I to p kam nahi karga toh kaisa pata chalaga sir

  • @RameshGupta-xl4iz
    @RameshGupta-xl4iz ปีที่แล้ว

    see.Aap.Apna.Contect.N.Den