- Motorized MCCB | ACB wiring diagram /Drawing | how to wire Motorized Breaker with Remote control @DieselGeneratortraining
#Motorizedacb #motorizedmccb #dieselgenerators
Wiring Diagrams - ComPact NSX
Schematics with ComPact NSX Circuit Breakers - วิทยาศาสตร์และเทคโนโลยี
Best technical video tutorials
1. Dse 7320 full course video tutorial
lnkd.in/dCPHvrk
2. How to read Electrical Drawings Video tutorial
lnkd.in/g8v6BEG
3.how to bypass generator AVR
lnkd.in/dP6Xn-Kd
4. Three phase genrator excitation system video tutorial
lnkd.in/dE8ZDz3
#generator #dieselgenerator #generators #Electricgenerator #electricalengineering #electricalengineers #Engineering
#Electrical #techjobs #technicalsupport
Hw can I get Yu what apps number pla
Thank for clear explanation
Ⓥⓔⓡⓨ ⓖⓞⓞⓓ ⓔⓧⓟⓔⓝⓔⓣⓘⓞⓝ 👍
Thank you sir
Super
Good 👍
Thank you! Cheers!
Very good explanation! Thanks 😅
Glad it was helpful!
remote operation k through breaker trip aur reset kaise hota hai iska working explanation video banayie sir
Nice info..great job bro thank you
Always welcome
Really a great effort
I have a question auxiliary SDE contact when change its position.suppose breaker is off point 81 and 82 are closed .but when breaker turn on then SDe also change its contacts my means 81 and 84 becomes close or only it change contacts position when it get trip.
Please clear this point
It closes only when there is trip alarm
Can you explain me the function of the shunt Trip in a motorized breaker? With the elec diagram ? please
Thank you so much
You're most welcome
HOW CAN I KNOW THE OPEN RELAY IS UVR OR MX. WITHOUT OPENING THE BREAKER.
Thanks a lot.
Please can you send me the wiring diagram for using ats this type of ACB.with 3 timer and relays with selector switch auto off manual
brod can you give me a diagram for this circuit breaker,
Sir,I have schneider air circuit breaker EDO type.
I have one question
air circuit breaker its close position ,once power coming its should not be operate automatically ..
In this situation what have to do ?
Because ,our side local supply not well running 10 minutes coming after shut down after again 2 minutes coming ...
So I want automatically on controll manually..
Same question but my acb is lagrand. Breaker is not connected to supply to the mains because when power off the generator runs and few seconds it stop because the acb is not connected to bus line how to fix it sir and how to know the problem. I have 3 coils UVT, CC, SHUNT.
In NW breaker have 3 positions. A1, A2 , A3
I will see
Al samalo aleekm
Please I need to contact you
Same question but my acb is lagrand. Breaker is not connected to supply to the mains because when power off the generator runs and few seconds it stop because the acb is not connected to bus line how to fix it sir and how to know the problem. I have 3 coils UVT, CC, SHUNT.
Ur doing Generator synch with Grid supply
@@DieselGeneratortraining yes brother but there has no connection if there power interruptions the breaker is not function to close
Explain in Hindi please isi liye vew kam hai
Ok bhai
Hindi please sir
what would cause the breaker to closed then immediately open again
The mechanism
Thanks sir