Electrical safe isolation procedure - Single Phase

แชร์
ฝัง
  • เผยแพร่เมื่อ 2 ธ.ค. 2024

ความคิดเห็น • 27

  • @BrentLix
    @BrentLix ปีที่แล้ว +2

    I'm going through a career change and decided to carry on the family trade by training to be an electrician. This video is so clear and well-structured that it has helped me more than my tutor ever could. This video has made it so easy to understand for someone who struggles to study.
    Thank you

  • @jeffsnipes8766
    @jeffsnipes8766 2 ปีที่แล้ว +1

    As a 28 year electrician 12 years with a masters license here in America I find your practices very interesting. We don’t send our transformers to ground the way you do. We verify the circuit is dead to our MDP by voltage readings, Not continuity. The cables you use are interesting to me as well because we run conduit for all main lines unless it’s bus duct up a high rise or through a production facility. I wonder if the NEC adopted some of the ways you do things if we could actually make it cheaper and more efficient for the end customer. I only found you a few days ago but I’ve enjoyed your content keep it up.

  • @rscelectrical7091
    @rscelectrical7091 2 ปีที่แล้ว

    It still amazes me the number of people that either use a Multimeter to test for safe isolation or just don't bother at all, they just flick the switch off and trust that it's done the job😢. Another great video that hopefully people will take notice of.

  • @georgegeorgel7254
    @georgegeorgel7254 หลายเดือนก่อน

    Before anything else u must seek for the permisssion first and then turn off any individual circuit braker and rcd to reduce the load and then the main switch and lock it off and diplay the sign and the key must stay in your pocket at all times

  • @krishtheobald4227
    @krishtheobald4227 2 ปีที่แล้ว +3

    Great stuff as always Mike!
    One thing that JW had mentioned which I think is important (you sort of mentioned it), is that even on an approved voltage indicator with a digital display and the indicating lights, the indicating lights are what is supposed to be relied on, not the display.
    Looking forward for your 3 phase video 😁

  • @sergiofernandez3725
    @sergiofernandez3725 2 ปีที่แล้ว +1

    Good video. Nice to see you showing the lockout was one step back from the kit you intended to work on. I look forward to the 3 phase video.

  • @Aids9898
    @Aids9898 ปีที่แล้ว +2

    Watching this in college rn

  • @damiandrozdek5688
    @damiandrozdek5688 2 ปีที่แล้ว

    Following you from about 2 years. Learn a lot, happy to see you going forward 👌⚡️

  • @lukeashton7085
    @lukeashton7085 2 ปีที่แล้ว +5

    Single Phase installations test to confirm that there is no voltage between:
    - Line and Neutral
    - Line and Earth
    - Neutral and Earth.
    3 Phase installations test to confirm that there is no voltage between:
    - L1 and L2
    - L1 and L3
    - L1 and Neutral
    - L1 and Earth
    - L2 and L3
    - L2 and Neutral
    - L2 and Earth
    - L3 and Neutral
    - L3 and Earth
    - Neutral and Earth

    • @TheChipmunk2008
      @TheChipmunk2008 2 ปีที่แล้ว +1

      heck yes, I proved L-N and L-E on a system a couple of years back, small house, being redone, didn't prove properly and got a massive 'lock on' belt through N-E (reversed polarity plus switching in the neutral :\ ) That will teach you more than any amount of lectures :(

  • @walseee
    @walseee 2 ปีที่แล้ว

    Great videos as usual. Your more recent videos have got drastically better quality and you seem a lot more comfortable on camera. Keep it up 🙂

  • @donstir23
    @donstir23 2 ปีที่แล้ว

    Quality as always brother .. appreciate the refresher on the process at hand . Stay safe Mickey 👍

  • @Dog-whisperer7494
    @Dog-whisperer7494 ปีที่แล้ว

    Excellent advice but just one point of correction GS38 requires that we prove our voltage indicator on a known source or a proving unit rated to the same voltage as the voltage we are testing. A known source can be the incoming side of the main switch . Other than that fantastic advice and video nicely explained and well presented 👍

  • @PhilipHudnott
    @PhilipHudnott 2 ปีที่แล้ว

    Good clear video. Only thing I would say is you need covers on your probes as I believe GS38 states maximum of 4mm of tip should be exposed.

  • @charliechan22
    @charliechan22 2 ปีที่แล้ว

    You are a fountain of knowledge. I have the t6-1000. I was looking at the new prv240fs proving unit. Just double checked and it only goes up to 240v. Might have to look at the tried and trusted Martindale one.

  • @georgegeorgel7254
    @georgegeorgel7254 หลายเดือนก่อน

    For thre phase safe isolation u must test with an approved voltage indicator and approved voltage proving unit between the least most dangerous conductor first neutral L1,L2 and L3 then between the earth L1,L2 and L3 then between the least most dangerous conductor first earth and neutral and then between L1-L2,L1-L3,L2-L3 thats the ten stages 3 phase safe isolation🤓

  • @three-phase562
    @three-phase562 2 ปีที่แล้ว +2

    Great video RC! Like how you have put a deliberate error in there for people to find 👍😉
    I would add to be aware of if it is a double pole isolation, that also breaks the neutral as is the case in your video, or if it is a single pole isolation that breaks only the live. If it is single pole, then the test for dead procedure will not pick up a borrowed neutral fault, until the neutral is broken. Under this situation, after the isolation and initial test for dead, I would break the neutral as live working, and then test for dead again. This is more likely in a commercial / industrial installation however, a similar scenario exists for a PEN fault to a domestic premises, where a two pole tester may show the installation to be dead, when in reality there is still power. In this case a sweep with a non-contact voltage pen would show the live wires, or you need to find a true earth for the two pole tester.

  • @georgegeorgel7254
    @georgegeorgel7254 หลายเดือนก่อน

    In single phase is three stages and in three phases is ten stages am2 am3

  • @jackdavis8786
    @jackdavis8786 2 ปีที่แล้ว

    Great videos, great content, be good to see a series of the testing procedures

  • @goose4342
    @goose4342 2 ปีที่แล้ว +1

    Wait I’m confused I thought you had three phase power in 🇬🇧 for residential. But you’re saying single phase, is it single/split phase like we have in the 🇺🇸.

    • @jackdavis8786
      @jackdavis8786 2 ปีที่แล้ว +3

      No single phase for residential

    • @goose4342
      @goose4342 2 ปีที่แล้ว +1

      @@jackdavis8786 okay cool, thanks for clarifying.

    • @skellious
      @skellious 2 ปีที่แล้ว

      Some new builds are now getting full 3-phase due to the requirement for new homes to accommodate an electric car charger and for heatpump installations.
      But normally a street has 3 phase along it and one phase to each house, divided equally. Because we have 100A 240V as standard into homes we can usually cater for quite a lot of load on one phase.

  • @kingofthetrowel1725
    @kingofthetrowel1725 2 ปีที่แล้ว

    Nice one mate very educational and helpful 🙌🏻 keep them coming 👌👌👍👍

  • @ahmadaliwi6827
    @ahmadaliwi6827 ปีที่แล้ว

    Great

  • @electroaid
    @electroaid 2 ปีที่แล้ว

    No devices, no gimmicks will save you from live current but some mild creative thinking might. Instance, your elbow on the side of the enclosure while working one handed on a wire harness you've never laid eyes on before. Your forearms might suffer but your chest is safe. Just one example but eh, you do you. Not like your gonna listen anyway.

    • @electroaid
      @electroaid 2 ปีที่แล้ว

      @@residualelectrical Agreed, point is don't rely on safety gimmick but also don't rely on some safety tip your read about somewhere. I would say think and try to experiment with but that's also a dangerous venue. So instead my message to you brave souls is, god's speed.