This Module Makes the EST Genesis 4 Wire! - Edwards Master Sync Module

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 ม.ค. 2025

ความคิดเห็น • 23

  • @GabetheSlacker
    @GabetheSlacker 7 หลายเดือนก่อน

    Will that work with other 2-wire fire alarms or just the EST Genesis?

  • @TheCarson116
    @TheCarson116 4 ปีที่แล้ว +2

    Well Aaron, you are all about showcasing the technical side of fire alarm systems aren't you? First I find your video on using an MP3 board to give your panel the ability of voice evacuation, and now I find this one, showing that it's ACTUALLY POSSIBLE to run Genesises as 4-wire! I genuinely thought that Edwards was the one brand that didn't have ANY kind of "selective silence" option, given the apparent lack of an "Edwards Sync" option on panels and no sync module either, but I guess I was wrong! Just like with all other selective silence-capable 2-wire devices, it's impossible to code the horn to a specific code (like marchtime) other than code 3 or continuous, but it's still better than nothing I suppose. Thanks for showcasing this, I'll be sure to buy a Signal Master if I ever buy a 2-wire Edwards/EST horn/strobe (or chime/strobe).

    • @Picklebean72
      @Picklebean72 3 ปีที่แล้ว

      Actually you can code the genesis series to March time with the sync module. Not sure you can do that with any other 2 wire devices, but if you look up the specs, you can code genesis horn strobes with the module

  • @lumenfirealarms
    @lumenfirealarms 4 ปีที่แล้ว +1

    Cool!!

  • @joeycaridi3030
    @joeycaridi3030 3 ปีที่แล้ว

    Unfortunately it doesn't work for the LED EST Genesis

  • @denster1964
    @denster1964 4 ปีที่แล้ว +1

    Do you have your MS-5UD still? I am getting a Notifier SFP-5UD and I know a lot about it but my main question is, “Is it good panel?”

    • @Aaronproductions
      @Aaronproductions  4 ปีที่แล้ว +1

      I have a 10UD, the 10ud-7 has a switch mode power supply aka filtered DC; so i’m not sure how to compare them, especially since the 10 is good for use with mechanical horns as opposed to the 5. but overall that series is great and has amazing program flexibility, i’d say they’re the most advanced modern conventional system

    • @denster1964
      @denster1964 4 ปีที่แล้ว

      @@Aaronproductions thanks! I’ll do with the notifier because I only have common alarms that are everywhere, and it’s really all I need to start off my first system.
      Also yeah I agree. They have an SFP-10UD at my school and it’s pretty nice. I’m okay with the fact that it’s not the easiest panel to use because I found a good deal.

  • @AlarmSystemTech
    @AlarmSystemTech 4 ปีที่แล้ว +1

    Interesting nice review

  • @wolfyfloof4701
    @wolfyfloof4701 4 ปีที่แล้ว +1

    request for new system test 4

    • @Aaronproductions
      @Aaronproductions  4 ปีที่แล้ว

      I'll cross that road when I get to it, the system is not ready for ST4

  • @XboxMinion24
    @XboxMinion24 4 ปีที่แล้ว

    Can you Take Apart a Simplex Truealert for my request please?

    • @Aaronproductions
      @Aaronproductions  4 ปีที่แล้ว

      They're clear so I don't see the need to, but I will consider it

    • @XboxMinion24
      @XboxMinion24 4 ปีที่แล้ว

      @Aaron Productions alright

  • @Thing95
    @Thing95 ปีที่แล้ว

    HOW

  • @pvh_facp4001yt
    @pvh_facp4001yt 4 ปีที่แล้ว +1

    How much was yours? That’s pretty cool for that to exist.

    • @Aaronproductions
      @Aaronproductions  4 ปีที่แล้ว +1

      Pieter van Ham -FACP4001- $5

    • @pvh_facp4001yt
      @pvh_facp4001yt 4 ปีที่แล้ว +1

      Aaron Productions interesting. I might think about it for my Genesis.

    • @Flanks719
      @Flanks719 2 ปีที่แล้ว

      Im getting one it was 52 dollars cause im in Canada

  • @wolfyfloof4701
    @wolfyfloof4701 4 ปีที่แล้ว

    Request system test 4