Reinforcement details for 16 feet span beam

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 ก.ย. 2024
  • Number of steel bars used in this beam is 4 nos
    Top 2nos of 16mm
    Bottom 2nos of 16mm
    Top extra bar is 2nos of 16mm
    Bottom 2nos of 16mm

ความคิดเห็น • 18

  • @vvs9610
    @vvs9610 2 ปีที่แล้ว

    Column size & how many floors.

  • @saarthakkumarlal6371
    @saarthakkumarlal6371 2 ปีที่แล้ว

    What is beam size without slab thickness..??

    • @nasirmir8771
      @nasirmir8771 2 ปีที่แล้ว

      12 inches height without slab ..and 8 10 inches width... 16 mm 4 Roda + 2 Roda 12 mm if span is over 10 feet ... Otherwise 12 mm 8 rods is ok.. ring space should be 7to 9 inches .. Not more .

  • @ABDULHAKIM-xt5xs
    @ABDULHAKIM-xt5xs 3 ปีที่แล้ว

    Hi sir
    Tension will be at bottom
    So the extra bars which you have provided should be equal to the bottom bars
    But you have provided cut length their
    Correct me if I'm wrong

    • @lineup6942
      @lineup6942  3 ปีที่แล้ว +2

      Yes you are correct
      I have provided equally
      Compression rod at top as 2 16mm extra
      Tension rod at bottom 2 16mm extra

  • @apurbasulekhaconstruction1519
    @apurbasulekhaconstruction1519 2 ปีที่แล้ว

    Sir I have used 4 no 12 mm rod on column for g+1 ,one column to column center distance 12.10 feet and another 11 .10 center distance what would be beam size and can I use 16 mm 4 rod on beam

  • @kapilbhagat2374
    @kapilbhagat2374 2 ปีที่แล้ว

    Hlo Sir.. If column to column span is 30ft.. Then what the reinforcement we should use? How many bars at the bottom & top

  • @keshavanand3868
    @keshavanand3868 3 ปีที่แล้ว

    if in the column 12mm rod is used then we provide 16 mm rod in beam for 16 feet span?

    • @lineup6942
      @lineup6942  2 ปีที่แล้ว +2

      No problem

    • @bengaluruengineer8270
      @bengaluruengineer8270 2 ปีที่แล้ว +2

      Always provide strong column and weak beams.. that's the concept of structural design.

    • @lineup6942
      @lineup6942  2 ปีที่แล้ว +1

      Column reinforcement is depend on the no of floors
      Beam reinforcement depends on the span and load that going to act

  • @mandeepsingh616
    @mandeepsingh616 2 ปีที่แล้ว

    sir mera 20 by 12 room all side beam hai ..kya bich m hiden beam dena jroori hai ..?

  • @suvrodahal
    @suvrodahal 3 ปีที่แล้ว

    It is for how many story building?..if any building less than the number of storey of your building..will configuration change?..for example g+2 building.. thank you..

    • @lineup6942
      @lineup6942  3 ปีที่แล้ว

      Only columns size will be vary depending upon the stories of building
      According to beam it will differ only when Loading differ

    • @lineup6942
      @lineup6942  3 ปีที่แล้ว

      The following beam design can carry
      The roof slab's dead load of 2KN
      And live load of 3 KN and brick wall dead load of 2KN
      Total 7KN load it can carry

    • @suvrodahal
      @suvrodahal 3 ปีที่แล้ว

      Thank you for your response..U said that depth of beam is 18 inches..is it including the slab..how much is the slab?..

    • @lineup6942
      @lineup6942  3 ปีที่แล้ว

      We will insert the slab's reinforcement bar into the beam
      So the slab will get concealed into beam
      Slab here is a one way slab and thickness is 5"

    • @suvrodahal
      @suvrodahal 3 ปีที่แล้ว

      Thank you sir..