UT Tip Diffracted Signal
ฝัง
- เผยแพร่เมื่อ 22 ก.ค. 2024
- This video demonstrates how to measure the depth of an EDM notch using the tip diffracted signal.
Equipment: Olympus EPOCH 1000i UT tester, 45 degree, 4Mhz, 10mm diameter transducer and a carbon steel bar that contains a 0.300" high ID connected EDM notch.
I work at Central Piedmont Community College in Charlotte, NC. Please visit our website to explore your NDE training needs.
Central Piedmont Community College NonDestructive Examination Technology Program
www.cpcc.edu/programs/nondest...
Central Piedmont Community College NonDestructive Examination Technology Program College Catalog
catalog.cpcc.edu/programsofstu...
you are very honest sir.
Very educational thanks.
Just to add on this, if you wanted to measure the height of an imbedded crack, you'd need a top and bottom tip and measure the difference between those.
Part T - depth of diffracted signal = through-wall height
@@rodstephens742 some clients require actual flaw height. Not all cracks are id or od connected.
can you make a video of mode conversion