UT Tip Diffracted Signal

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 ก.ค. 2024
  • This video demonstrates how to measure the depth of an EDM notch using the tip diffracted signal.
    Equipment: Olympus EPOCH 1000i UT tester, 45 degree, 4Mhz, 10mm diameter transducer and a carbon steel bar that contains a 0.300" high ID connected EDM notch.
    I work at Central Piedmont Community College in Charlotte, NC. Please visit our website to explore your NDE training needs.
    Central Piedmont Community College NonDestructive Examination Technology Program
    www.cpcc.edu/programs/nondest...
    Central Piedmont Community College NonDestructive Examination Technology Program College Catalog
    catalog.cpcc.edu/programsofstu...

ความคิดเห็น • 6

  • @arifbugga7186
    @arifbugga7186 3 ปีที่แล้ว +1

    you are very honest sir.

  • @ahmedmusawi5425
    @ahmedmusawi5425 4 ปีที่แล้ว

    Very educational thanks.

  • @programmerdave9425
    @programmerdave9425 ปีที่แล้ว

    Just to add on this, if you wanted to measure the height of an imbedded crack, you'd need a top and bottom tip and measure the difference between those.

    • @rodstephens742
      @rodstephens742 5 หลายเดือนก่อน

      Part T - depth of diffracted signal = through-wall height

    • @programmerdave9425
      @programmerdave9425 5 หลายเดือนก่อน

      @@rodstephens742 some clients require actual flaw height. Not all cracks are id or od connected.

  • @arifbugga7186
    @arifbugga7186 3 ปีที่แล้ว +1

    can you make a video of mode conversion