04# Installation of switchgear, inverter and battery storage for PV
āļāļąāļ
- āđāļāļĒāđāļāļĢāđāđāļĄāļ·āđāļ 18 āļ.āļ. 2023
- Hi builders ð . Welcome to the next video in the series about photovoltaics. We already have a roof full of photovoltaic panels, but they are not producing electricity yet. So we're going to continue and look at the installation of the inverter, the two distribution boxes and the battery storage assembly. So let's get to it ð.
Previous video ð bit.ly/3NGo8Hs
Next video ð coming soon
USED PHOTOVOLTAIC POWER PLANT ASSEMBLY ð:
ENBRA photovoltaic system for single family and apartment buildings ð bit.ly/3nj0Lc8
When making a non-binding enquiry, use the special offer code "self-help" and you will get the following extra:
ð subsidy processing in the value of 8.000 CZK - FREE
ð main PV switchboard (AC switchboard) worth 9.900 CZK - FREE
#enbra #blaklader #photovoltaics
------------------------------------------------------------------------------------------------------------------------------------------------------
ð Give us a LIKE and SUBSCRIBE so you don't miss out on more videos!
ð CONSTRUCTION NEWS ON THE NETS
/ svepomoci
/ svepomoci
ð TO READ AND SOMETHING TO WEAR
eshop.svepomoci.cz/
www.ZakladovaDeskaSvepomoci.cz
www.HrubaStavbaSvepomoci.cz
â INTERESTING POSTS YOU WILL FIND
www.Svepomoci.cz
www.Svepomoci-ZIVE.cz
ð KEEP TRACK AND SAVE
vstupenky.svepomoci.cz/
www.NakladyNaStavbu.cz/
ð POUÅ―ITÃ SESTAVA FOTOVOLTAICKÃ ELEKTRÃRNY:
FotovoltaickÃ― systÃĐm pro rodinnÃĐ i bytovÃĐ domy ENBRA ð bit.ly/3nj0Lc8
PÅi nezÃĄvaznÃĐ poptÃĄvce pouÅūijte akÄnà kÃģd "svÃĐpomocÃ" a pÅi realizaci navÃc zÃskÃĄte:
ð vyÅÃzenà dotace v hodnotÄ 8.000 KÄ - ZDARMA
ð hlavnà FVE rozvadÄÄ (AC rozvadÄÄ) v hodnotÄ 9.900 KÄ - ZDARMA
, , ,.
,, , ,.
DÄlÃĄm FV uÅū 16 let a kdyÅū uÅū to zaÄne hoÅet tak v 99% pÅÃpadÅŊ v DC rozvadÄÄi, proto bych ho nikdy nedal na pÅŊdu.....chÃĄpu Åūe je to z dÅŊvodu vzdÃĄlenosti svodiÄÅŊ od panelÅŊ a dle norem ok, ale vidÄl jsem jich pÃĄr hoÅet a takovÃĄto destiÄka pod rozvadÄÄ rozhodnÄ nepomÅŊÅūe. Je to ale tÄÅūkÃĐ, kdyÅū si tu u nÃĄs normy stanovujà vÃ―robci svodiÄÅŊ (hlavnÄ kluci z DEHNu)...pak to takto dopadÃĄ a vznikajà takovÃĐ pasvily kterÃĐ mÃsto aby rizika sniÅūovali tak je naopak zvyÅĄujÃ........
Jenom by mÄ zajÃmalo, jak bude stÅÃdaÄ mÄÅit, kdyÅū digitÃĄlnà elektromÄr nenà umÃstÄn na patici domu ? TakÃĐ jsem nikde nevidÄl, Åūe by zapojovali N 0% pro vazebnà stykaÄ, ten je veden z HDO...
OddÄlovacà relle pro fveO% v rozvadÄÄi aÄ, nebo u hodin?
No ja Vam neviem ale ako elektrikar by som zacinal najskor pripojovanim corahnneho ZZ vodica az potom pokracoval s ostatnymi castami
A navÃc umÃstit rozvadÄÄ tak nÃzko u zemÄ, je docela Úlet.
A ked trafi blesk do panelov, tak cez "uzemnenie", ako je to urobene tu, dostane 100% zasah vsetko, co je pripojene v zasuvkach a ma zapojeny ochranny vodic, nie?
DobrÃ― deÅ, preÄo by dostalo zÃĄsah vÅĄetko ? ako inak by sa to malo urobit podla Vas? Äakujem za odpoveÄ
MÃĄÅĄ tam pÅepÄÅĨovky kterou to odpÃĄlà a mÃsto 1mil korun to rozbije pÅepÄÅĨovku za 8 k
@@ElektroDCAC FAkt? Majà to pÅipojeno na LPS, takÅūe pÅed vstupem do budovi SPD1, majÃ? V DC rozvadÄÄi majà dvojku, ale majà mÃt jedniÄku, takÅūe podle norem to nemajà a fakt vÄÅÃte, Åūe kdyÅū nedodrÅūeli normy, Åūe to skonÄà na T2 za 8tisÃc? (pÅedraÅūenÃĐ, tedy podle cenÃkÅŊ)...
SvodiÄe v DC rozvadÄÄi jsou tÃmto zpÅŊsobem ÚplnÄ k ðĐ. PÅÃpadnÃĐ pÅepÄtà se dÃky soubÄhu naindukuje zpÄt na vodiÄe za svodiÄem a do stÅÃdaÄe zase dobÄhne pÅepÄtÃ. DÃĄle DC vedenà mÃĄ vÃce neÅū 10m (tÅeba se pletu), pak by tam mÄla bÃ―t jeÅĄtÄ druhÃĄ sada svodiÄÅŊ.
PS: viditelnÃ― zpÅŊsob zastÅihÃĄvÃĄnà vÃĄzacÃch pÃĄskÅŊ je dÄs. ZalamovacÃm noÅūem, pÅÃpadnÄ ÅĄtÃpacÃmi kleÅĄtÄmi s vyhnutou Äelistà lze zastÅihnout zcela hladce a nehrozà tak poranÄnà o ostrou hranu.
Domovnà rozvadÄÄ je taky parÃĄdiÄka, svodiÄ obsklÃĄdanÃ― vÅĄÃm moÅūnÃ―m a ZÅ― jeÅĄtÄ taÅūenÃ― spletà dalÅĄÃch drÃĄtÅŊ. Tam aÅū se jednou dostane pÅepÄtÃ... Snad obyvatelÃĐ budou mÃt dobrou pojistku a pojiÅĄÅĨovna nebude moc zjiÅĄÅĨovat :)
DÄkujeme za nÃĄzor. VÅĄe bylo pÅed realizacà konzultovÃĄno s elektrikÃĄÅem a reviznÃm technikem. Instalace proÅĄla po dokonÄenà revizà prohlÃdkou. Proto povaÅūujeme toto provedenà za sprÃĄvnÃĐ.
@@svepomoci ChÃĄpeme, mÃĄte platnou revizi, kterou lze prÃĄvnÄ spochybnit, takÅūe si myjete ruce :D
@@svepomoci Pokud se oprostÃte od odbornÃkÅŊ, reviznÃch technikÅŊ, ... a zapojÃte selskÃ― rozum ke znalostem, kterÃĐ mÃĄte, musà vÃĄm dojÃt, Åūe tohle sprÃĄvnÄ nenà ani omylem. Pokud je to pro vÃĄs sprÃĄvnÄ, divÃm se, Åūe vÃĄm elekrikÃĄÅ jeÅĄtÄ neporadil natÃĄhnout vnitÅkem pÅes domovnà rozvadÄÄ i bleskosvod, protoÅūe to je stejnÃ― level, kterÃ― prokÃĄzal pÅi zapojovÃĄnà vaÅĄÃ fve. Äest prÃĄci.
@@svepomoci tak to se bohuÅūel pletete , poruÅĄuje to i montÃĄÅūnà nÃĄvod vÃ―robcÅŊ pÅepÄÅĨovÃ―ch ochran.
rozvadec v roce 2000, vystacil si s 20-30 pozicema a byl z poloviny prazdny, .... rozvadec v roce 2020+ ...... znamena 3 rozvadece, a odhadem obsahuji cca 150 pozic, a jsou zcela plne :D
no ja si teda chytry dum predstavuju asi jinak, tohle co vidim na videu je spise strasnej bordel ve kterem se za 20 let zadnej elektrikar nevyzna, a kdys to uvidi, tak prohlasi ze ten kdo to instaloval tak chtel vydelat a ne delat.... taove to tady nekde v tom rozvadeci nastal problem.......hledej Smudlo
ja se vlstne ani nedivim ze si dnes lidi delaj fotovoltaiku svepomoci a casto i ostrovne, protoze kdys vidim co vidim, tak tohle bych doma fakt nechtel, to vypada spis jako ridici elektronika pro start raketoplanu ktera sama osobe bude mit spotrebu silenou, co me fakt dostalo bylo i to jak to instaluji ve 2-3 lidech, jeden drzi metr a druhej cmara tuztickou na tram, normalne jsme cekal ze vytahnou nejake laserove zamerovani aby to bylo na tom tramu pridelane presne na tisicinu milimetru....strasne me bavi priprava nehorlave desky a nasledna montaz na drevo a do mistnosti vystlane polistirenem, no jak dlouho asi takovej DC rozvadec vydrzi pokud se tam vytvori obloucek? ta deska to vyslovene zachrani.....to neslo ten DC rozvadec taky udelat az dole v technicke mistnosti? musela bejt na pude?
ja mam teda radsi vechno pekne v jedne mistnosti aby pripadne problemy vznikali na jednom miste, a kor ty z DC casti systemu, kde je riziko nejvetsi
Je patrnÃĐ, Åūe nemÃĄte vÅŊbec tuÅĄenà o Äem pÃÅĄete....
Dle Äeho usuzujete? Po 26 letech realizovÃĄnà staveb domÅŊ a obchodnÃch parkÅŊ, mohu slova pÃĄna jedinÄ potvrdit.
@@rostabukacek350 delam elektriku a plyn je kratce, nejakych 25 let, takze ano mate pravdu ze nemam tuseni o cem pisu