Excellent sir, today on my resident side i have to check breakdown of 20kw delta inverter ,same as shown in your vedio. Your vedio help me a lot,thanku so much for that, but I have many questions can you help me please.
1)How to check that generated three phase power is used or not and how much power is consumed 2) how it is integrated with main supply from government, so that in evening after sunset or in case of low power generation it can switch to main power supply.
1) check main meter of the building where solar is installed , if the net meter is exporting power back into the grid , that means there is excess 3phase solar power which was not consumed. Compare the exported power with generated power of solar plant. If there is no export in grid in main meter but import only , that means complete solar power is consumed. 2) it's called grid synchronisation it happens on its own
Actually i have to install a 250 kw ground mounted solar plant. In this case i just want to know why we should use string inverters in place of a single inverter of 250 kw? How string inverter will be beneficial over single inverter?
@@SustainableEveryDay sir if we have to design 100kw plant, how to give a priority of inverter means 25kw of 4 inverter or 50 kw of 2 inverter or 100kw of 1 inverter.
hi this is jatin darji from delta you can talk to our tech center for better support .for your information for low voltage can be grid side or loose connection.
I have a site of 390.4kwp which is showing continuous decrease in the PR value. We checked all the strings of the inverter and noted down all the open ckt voltage and string current. Still I am unable to track what's the fault. Can you please help
Hey Ragini following are my concern after understanding your situation , just choose the right observation which you might have missed , accordingly I will tell you the solution. 1) solar plant not getting proper cleaning 2)The PR value estimated via PvSyst software didn't consider shadow or soil loss and in actual the shadow and soil issue is there on site. 3)inter row space shadow issues due to civil issue 4) lot of hotspot in multiple modules , test it with thermal imaging 5)The solar panels are integrated and are unable to dessipate heat causing DC loss
That means the module backsheet is integrated and has less clearance for the heat to dessipate , the more the module heats up during peak hour of generation , the more it degrades and unable to achieve proper output power. Or there can be an issue with PR calculation , I would be only able to help you out after I go through the PV syst report of this site , and few pictures of the site and , google location
Nice video 👍
Nice explanation Mr. Himanshu
Thanks
Sir koi job bataye
200kw se zyada ke inverters available hai delta ke ?
Nice video Thanks Sir
Thanks for watching Aman jee
Excellent sir, today on my resident side i have to check breakdown of 20kw delta inverter ,same as shown in your vedio.
Your vedio help me a lot,thanku so much for that, but I have many questions can you help me please.
Sure please ask
1)How to check that generated three phase power is used or not and how much power is consumed
2) how it is integrated with main supply from government, so that in evening after sunset or in case of low power generation it can switch to main power supply.
Can you give me your What's app number or email id to send you some photos and vedios of 20kw PV solar system on my site in gurugram.
+91 9876976705
1) check main meter of the building where solar is installed , if the net meter is exporting power back into the grid , that means there is excess 3phase solar power which was not consumed. Compare the exported power with generated power of solar plant.
If there is no export in grid in main meter but import only , that means complete solar power is consumed.
2) it's called grid synchronisation it happens on its own
Sir MPPT pe ek achi video banao sir
Sir Event Log Me Error Events Me Agar Insulation Ka Error Aaye Toh Kaya Kare...?
sir 50kw ke inverter per maximum and minimum kitna dc kw connect kar sakte h
65kw tak
Thank you sir
Sir soler m job ka koi WhatsApp group Hai Koi
Howmany protection functions are available in delta inverter? How it works?
Sir,
Mere delta ke inverter me HW Comm1 error Aya hai..
Solution dijiye plz
Actually i have to install a 250 kw ground mounted solar plant. In this case i just want to know why we should use string inverters in place of a single inverter of 250 kw? How string inverter will be beneficial over single inverter?
Sir aap ka mo.. Dedo
👏👏
Thanks for the support
Ac High voltage per kya kre
Correct Country set kr dijiye
Dgr report email ka format k baare me guide kare sir
Hi, do you know how to repair Delta RPI 6 with failure HW CT A ? It's something with Current Transmitter.
The internal CT needs replacement , call delta service
Ok thanks, is it on the DC or AC part of Inverter?
Shadow analysis kese hota hai
Hi for shadow analysis the basic software for starting is Google sketchup
SPD fail hone per kya kare
Sir solar inverter me earth falt ko kaise check aur sahi karate hai
Maine ispe ek video upload keya hai may be aap ne vo dekha hai
how to contact delta people in AP, help
Call on the toll free number on Google they will connect you to vendor in AP
@@SustainableEveryDay thank you
Sir, how much unit will 50 kw inverter produce daily generally? How to calculate that?
1kw = 4kwh aprox
50kw = 200kwh aprox
@@SustainableEveryDay sir if we have to design 100kw plant, how to give a priority of inverter means 25kw of 4 inverter or 50 kw of 2 inverter or 100kw of 1 inverter.
@@SustainableEveryDay thank you sir
@@SustainableEveryDay your monthly data showed around 3000 units. Which avgs to 100/day =2units/kw/day. Which is half than what it should.
I want Delcen1000 model complete manual can you share me.
Sir ji solar system me voltage drop ho raha. so voltage drop kaise measure karege or use correct kaise kare ge
insulation ki vajah se ho raha he or check fuse
Plz do on sungrow inverter and it’s terminal connections of string inverters 2015-2018 models 50:60kw
please review RPI M6 A model so that it helps prospective buyers
Sure very soon
How to resolve AC voltage high of this inverter plz explain
Please aap 500kw inverter make.satcon main line voltage low generated ho raha hain ees ke bare main with video ke sath bataye thanks
Inverter firmware update hoga, also increase transformer tapping to increase voltage
hi this is jatin darji from delta you can talk to our tech center for better support .for your information for low voltage can be grid side or loose connection.
Sir i am facing so many issues from delta inverter my 150 kw plant is only 10 days old.
Delta inverter error event par ac voltage high hone ki wajah se generation me 60 unit ka difference aa rha he ise kaise sahi kre sir
I have a site of 390.4kwp which is showing continuous decrease in the PR value. We checked all the strings of the inverter and noted down all the open ckt voltage and string current. Still I am unable to track what's the fault. Can you please help
Hey Ragini following are my concern after understanding your situation , just choose the right observation which you might have missed , accordingly I will tell you the solution.
1) solar plant not getting proper cleaning
2)The PR value estimated via PvSyst software didn't consider shadow or soil loss and in actual the shadow and soil issue is there on site.
3)inter row space shadow issues due to civil issue
4) lot of hotspot in multiple modules , test it with thermal imaging
5)The solar panels are integrated and are unable to dessipate heat causing DC loss
Well ... It's a tin shed plant
We have done cleaning on 15th March itself.
That means the module backsheet is integrated and has less clearance for the heat to dessipate , the more the module heats up during peak hour of generation , the more it degrades and unable to achieve proper output power.
Or there can be an issue with PR calculation , I would be only able to help you out after I go through the PV syst report of this site , and few pictures of the site and , google location
@@SustainableEveryDay shall I mail you the PV syst report?
Delta service technician number?
Delta inv. Ki configuration setting kese kare
User manual se padh k , uske sath milti hai
Inveter on nahi horahai 50 kw polycab
Contact and lodge a complaint in service
Hello sir
What is complaint no./ coustomer care no. For 50 kva Delta inverter, nos given on website are no responce.if you have pl. Share..
Hi sir please call on this Delta service no.
+918067164700
If you have any issues please reach me at 9876976705
New plant ke liye mf kese nikalen
CT rating kitna hai
WH DSP ADC2
Alarm aa raha he
Hello sir HW comm1 error aa raha he
Inverter will be replaced
Sar ye said ham samarte he
Very Good Bhai
Im from delta
Standby mode
Pubg theme ringtone
Yes brother
Sar apna navar dena sar
Sir aap ka mo.. Do
Bus unbalance