Do you know the exact model of that PIR? It’s a Detection Systems one right? A bit like the Tri-Tech DS series. I haven’t been able to find any info on them anywhere. Edit: it’s actually an IQ220/260 made by Intellisense.
@@ArgaTheRexouium I used to mess around with these here in the US, I still have a d5200 somewhere. Beat up but go about 4-$500 last I checked on ebay (here in America anyways.) I mostly deal with Ademco/Honewell and dsc systems now.
I see you're too used to Vistas :P For the record, COMMAND 4 silences troubles, not entering your code + enter. also, code + enter silence and disarms, code + escape silences without disarming. code + escape is also used to clear the display (basically system reset). also also COMMAND 47 resets smoke detector alarms Cool to see a Radionics system in the UK though
Do you know the exact model of that PIR? It’s a Detection Systems one right? A bit like the Tri-Tech DS series. I haven’t been able to find any info on them anywhere.
Edit: it’s actually an IQ220/260 made by Intellisense.
The PIR looks to be a C&K intellisense
@@NyxKemo is the model an intellisense? Only asking because intellisense in the uk is a series of products by Honeywell.
@@alarmmuseum i don’t know the actual model of it but the series is Intellisense
How do you activate the fire alarm notification from the panel?
By activating a fire zone (either by a detector, or a manual activation point.
I didn’t know these systems were also used in the UK
Yep
www.ebay.co.uk/itm/142891950565?hash=item21450621e5:g:UokAAOSwa3BbYxEf
How well do these handle an external bell box?
Just fine you can't do anything with these panels without a d5200 programmer or using rps which is only available to registered installers
@@ArgaTheRexouium I used to mess around with these here in the US, I still have a d5200 somewhere. Beat up but go about 4-$500 last I checked on ebay (here in America anyways.) I mostly deal with Ademco/Honewell and dsc systems now.
I have a friend who can program them. Don’t ask me for his info.
Does another alarm sound like that I swear I had an old alarm that sounded like that
Bosch has a newer version with the same tones
command 1 love that system
I see you're too used to Vistas :P
For the record, COMMAND 4 silences troubles, not entering your code + enter.
also, code + enter silence and disarms, code + escape silences without disarming.
code + escape is also used to clear the display (basically system reset).
also also COMMAND 47 resets smoke detector alarms
Cool to see a Radionics system in the UK though
we dont really have vistas here instead we have ademco galaxy panels
Is that american
They exist both here in the UK and America