Ingersoll Scroll compressor UP6 30 coolant manifold thermostat valve removal, unit turning off

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ส.ค. 2024
  • Make sure to relieve all pressure and still some coolant oil will come out. I just wanted to show people what it looks like to remove this item. 12mm allen wrench required. It took a 2 foot cheater pipe to untighten it.
    The unit would turn off (due to over heating). The manifold wasn't letting fluid flow out to the radiator and back. Turns out the thermostat wasn't working. You could feel both fluid lines and they would have not much difference in temp. Under normal conditions, one would be too hot to touch, and the other would be almost room temp. The thermostat "pin" is supposed to extend out, when hot, and allow flow. We ordered the new part. But we made a spacer to hold it out, and allow flow all the time for now.

ความคิดเห็น • 12

  • @kompresorairteknologi
    @kompresorairteknologi 2 ปีที่แล้ว +1

    Nice sharing Video

  • @mnairengineering1985
    @mnairengineering1985 ปีที่แล้ว

    Good job

  • @MrRajivkumarsingh
    @MrRajivkumarsingh 2 ปีที่แล้ว +1

    Pls post the video where u have put a spacer to make fluid all the time flow through cooler till new spares recieved

    • @kyle_in_tex8422
      @kyle_in_tex8422  2 ปีที่แล้ว +1

      Sorry, but I don't have that video. We put a washer that fit into the line. If you don't clean out radiator and make sure of coolant's temp delta, you will have trouble. Hot coolant line will be too hot to touch and cool line will be about 40C. Also, if unit is exposed to freezing temps without thermostat, you will have trouble. Thank you.

    • @Something-cw6ev
      @Something-cw6ev 2 ปีที่แล้ว +1

      You mean bypass thermal valve?

  • @williamtibaquira2797
    @williamtibaquira2797 2 ปีที่แล้ว +1

    amigo buenos dias, tengo un problema de temperatura alta en un compresor Kaeser 250cfm, parece que no esta refrigerando bien el compresor, puede ser que el aceite no este haciendo su recorrido como debe ser por el radiador, pero no se como funciona esta valvula termostato. no encuentro información mas precisa

    • @MadaraUCHIHA-hy9xe
      @MadaraUCHIHA-hy9xe 2 ปีที่แล้ว

      Hi there, tow day ago we did fix a similar problem who did take a long time to solve, so it seem the thermostatique vile malfunction, we did temoporary fix it by bypassing it untile the spare arrive, you could check the valve by putin it in cold then in hot water or oil, there is a good chance it is the problem,if you did check the filters of oil and air, also the oil level.

    • @MadaraUCHIHA-hy9xe
      @MadaraUCHIHA-hy9xe 2 ปีที่แล้ว

      If you could reply to me the result you go,

    • @MadaraUCHIHA-hy9xe
      @MadaraUCHIHA-hy9xe 2 ปีที่แล้ว +1

      Look for this video in youtube: How to bypass the thermostat valve?? (for screw air compressor)

  • @PankajKumar-ko6iv
    @PankajKumar-ko6iv ปีที่แล้ว

    Compressor air outlet se oil bahar Q ataa hai?

  • @usamakhanusamakhan6158
    @usamakhanusamakhan6158 2 ปีที่แล้ว +2

    Hi i work in Atlas copco compressor

  • @MadaraUCHIHA-hy9xe
    @MadaraUCHIHA-hy9xe 2 ปีที่แล้ว

    What did you find ?