PowMr New Version keeper Charge Controller Setup

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ม.ค. 2025

ความคิดเห็น • 210

  • @asadahmed4708
    @asadahmed4708 ปีที่แล้ว +12

    Please remake the current manual book with full details and adding this function,i already bought this 20 amp controller and confused about some function because the current manual book don't have written the function's about you told

  • @jethroasuncion6080
    @jethroasuncion6080 11 หลายเดือนก่อน +1

    Hi! I am using the 1230 model with a 24V Gel battery bank setup. Note that I am using the preset parameters for GEL type batteries. The charge controllers indicate that I have a 23V power input however it shows that there is no charge current. Batteries are currently at 25.1V, if I am correct, according to the settings, this controller should start charging the batteries. Am I doing something wrong?

    • @PowmrSolar
      @PowmrSolar  11 หลายเดือนก่อน +1

      Hi, please send your problem to this email: support@powmr.com. Please note that we may not be able to promptly respond to you due to the Lunar New Year. We apologize for the inconvenience this may take and thank you for your understanding. We wish you all the best!

  • @martinwragg8246
    @martinwragg8246 ปีที่แล้ว +1

    Can the firmware be updated?
    I have V1.4

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Please send your problems to this email: support@powmr.com

  • @coupleadventure
    @coupleadventure 6 หลายเดือนก่อน +1

    I already have this same model, but how to activate the rotation display like the old model so i dont have to operate the botton just to see some details on display..

    • @PowmrSolar
      @PowmrSolar  6 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com.

    • @alvinramos-i2g
      @alvinramos-i2g 6 วันที่ผ่านมา

      ​@@PowmrSolar The default settings for low voltage is 10.8 , is it possible to change to higher value. Powmr 1220 20a

    • @PowmrSolar
      @PowmrSolar  6 วันที่ผ่านมา

      @@alvinramos-i2g Set USE first and then change it.

  • @matttelz6014
    @matttelz6014 10 หลายเดือนก่อน +1

    How to I adjust the Resume charge voltage? With Lifepo4 setting it is 13.0V which is too low.

    • @PowmrSolar
      @PowmrSolar  10 หลายเดือนก่อน

      Please set the battery type to USE1 so that you can adjust the parameters yourself.

  • @jamescarldelacruzchannel2633
    @jamescarldelacruzchannel2633 5 หลายเดือนก่อน +1

    I have the powmr 1220 version , and why the set AH is not decreasing on discharge AH?

    • @PowmrSolar
      @PowmrSolar  5 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com

  • @ronversluys1235
    @ronversluys1235 ปีที่แล้ว +1

    I am trying to figure out the LiFePO4 battery setting . I see in the instructions that they have listed LiPo and LiFe. When I enter that I have a 4-3.2v battery I get the symbol of LiFe. I have never seen the LiPo symbol. My question is do I have it set right? Thanks

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, please send your problems to this email: support@powmr.com

    • @baz69er13
      @baz69er13 3 หลายเดือนก่อน

      Yeh I'm having the same problem

  • @Jayromemagtipon07
    @Jayromemagtipon07 ปีที่แล้ว

    Hi. If i use 3-3.7 lipo battery still i need bms or no need

  • @ridowanhossain689
    @ridowanhossain689 หลายเดือนก่อน

    Does this display have any light to see the display after sunset?

    • @PowmrSolar
      @PowmrSolar  หลายเดือนก่อน

      The screen is always on, but when it gets darker, it becomes invisible.

  • @Shiloselectronics
    @Shiloselectronics 2 หลายเดือนก่อน

    How to factory reset this unit? Thanks

    • @PowmrSolar
      @PowmrSolar  2 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com.

  • @01lovemusic01
    @01lovemusic01 10 หลายเดือนก่อน +1

    Hi! I have two 260AH LifePo4 batteries 🔋🔋 Can you please me how to set into Powmr Power keeper 30A for this? 14.6V what mode? Is that USER2? Thanks.

    • @PowmrSolar
      @PowmrSolar  10 หลายเดือนก่อน

      Hi, please send your problems to this email: support@powmr.com. Our Technical staff will handle it for you.

    • @01lovemusic01
      @01lovemusic01 10 หลายเดือนก่อน

      @@PowmrSolar I did send it on March 08 but I got no response!

    • @PowmrSolar
      @PowmrSolar  10 หลายเดือนก่อน

      @@01lovemusic01 Can you send us your email?

  • @giogra8005
    @giogra8005 หลายเดือนก่อน

    I have the 40a but I want to use it without battery. Only solar panel and LOAD connected. It that possible? So when there is sun, I get power to the load and when it gets dark load goes off.

    • @PowmrSolar
      @PowmrSolar  หลายเดือนก่อน

      This controller needs to be connected to the battery before it can be turned on.

    • @giogra8005
      @giogra8005 หลายเดือนก่อน

      @@PowmrSolar Thanks for your help. It seems to work without battery too with panels in full sun. Another thing: I have an Ecoflow Pro, what battery type should I select?

    • @PowmrSolar
      @PowmrSolar  หลายเดือนก่อน

      @@giogra8005 Please send it to this email: support@powmr.com. Our technical staff will check it for you.

  • @mannynoleal7521
    @mannynoleal7521 ปีที่แล้ว

    Is this have a LCD backlight?

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, this model doesn't have a LCD backlight.

  • @martinwragg8246
    @martinwragg8246 ปีที่แล้ว

    Can 3 of these work in parallel connected to the battery with separate solar panels connected to each solar controller?

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, this model can't be used in parallel.

  • @md.mashiurrahman4678
    @md.mashiurrahman4678 3 หลายเดือนก่อน

    I am currently working with a 24V solar panel 250 Watt and a 12V battery 100 Mah . Could you please advise if it is possible to safely use this setup?

    • @PowmrSolar
      @PowmrSolar  3 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com.

  • @user-hershey_2015
    @user-hershey_2015 11 หลายเดือนก่อน

    This scc protect HVD,LVD....?

    • @PowmrSolar
      @PowmrSolar  11 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com.

  • @leebg852
    @leebg852 25 วันที่ผ่านมา

    Hi, one question? I have 4 lithium batteries (4-3.2v, 100A per battery) total 400A in parallel connection, in the setting page, is it adjust to 400Ah?

    • @PowmrSolar
      @PowmrSolar  23 วันที่ผ่านมา

      which model? Keeper 40A?

    • @leebg852
      @leebg852 23 วันที่ผ่านมา

      @ POWMR 1230

    • @PowmrSolar
      @PowmrSolar  22 วันที่ผ่านมา

      @@leebg852 Set 100AH ​​to charge normally. The battery type can be set to USE. If the charging voltage is set correctly, it can be charged normally. It has little to do with the capacity.

    • @leebg852
      @leebg852 22 วันที่ผ่านมา

      @@PowmrSolar so, what is that capacity parameter use for?

  • @ronversluys1235
    @ronversluys1235 ปีที่แล้ว +2

    Can anyone tell me if by picking the 4-3.2v battery then the LiFe symbol shows on the screen, are the charging parameters picked for me? I have a LiFePO4 battery and i dont need the resume, the constant voltage, equalization and absorption charge. All I need is the Low voltage protection and Float charge, Please correct me if I am wrong. Please tell me how to set this controller up correctly. Are the charging parameters user adjustable? Thanks

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, please send your problems to this email: support@powmr.com.

    • @martinwragg8246
      @martinwragg8246 ปีที่แล้ว

      Hi, did you get an answer to your questions, I am going around in circles here !

    • @ronversluys1235
      @ronversluys1235 ปีที่แล้ว +1

      @@martinwragg8246 I got no help from powmr support. I studied every you tube I could find and eventually put my project on a shelf for later. I did feel by trying different button pushes I did get better at it but in the end I dont know if its set up right. I have an Epever MPPT that has a remote programer (M50 i think) that is much more user friendly and not much more money.

    • @bustersbashers2280
      @bustersbashers2280 9 หลายเดือนก่อน

      Same here….!

  • @moesuki2810
    @moesuki2810 ปีที่แล้ว +1

    The maximum value of the output load terminal is approximately how many amps?

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว +3

      5A.

    • @adofatma2400
      @adofatma2400 7 หลายเดือนก่อน

      ​@@PowmrSolarthe manual book says DC output rated discharge current is 20A for 1220 and 1230, and 30A for 1240. Which one is correct?

    • @PowmrSolar
      @PowmrSolar  7 หลายเดือนก่อน

      @@adofatma2400 Yep, the rated charge current is 20A for 1220; 30A for 1230; 40A for 1240.

  • @edilbertoego-ogan
    @edilbertoego-ogan 11 หลายเดือนก่อน

    My Pow keeper1220 new version is not changing display is it good or not ?

    • @PowmrSolar
      @PowmrSolar  11 หลายเดือนก่อน

      Hi, kindly send your problems to this email: support@powmr.com

  • @davydacounsellor
    @davydacounsellor 2 หลายเดือนก่อน

    I see that lead acid batteries drop to 10 volts before shut off, this voltage is considered too low and can damage lead acid batteries, can voltage be configured so as shutoff is 11.4 volts. Thanks from Ireland

  • @MdSumon-ii9zr
    @MdSumon-ii9zr 6 หลายเดือนก่อน

    A few days ago, I bought the 30 amp machine that connected a Jinko 580-watt 24-volt panel. I am not getting any response from this machine, although the weather in my area is not good, the sun has not risen due to rain. Will I get no output from this controller if it's not sunny?

    • @PowmrSolar
      @PowmrSolar  6 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com.

    • @MdSumon-ii9zr
      @MdSumon-ii9zr 6 หลายเดือนก่อน

      @@PowmrSolar How to turn on photovoltaic input?

    • @PowmrSolar
      @PowmrSolar  6 หลายเดือนก่อน

      @@MdSumon-ii9zr Kindly check your email.

    • @MdSumon-ii9zr
      @MdSumon-ii9zr 6 หลายเดือนก่อน

      @@PowmrSolar please send

  • @tomaswilliam8765
    @tomaswilliam8765 หลายเดือนก่อน

    Oi. Eu comprei o controlador. Ele veio sem o Manual. E eu não estou conseguindo configurar o controlador 1240 para o banco de bateria de 12v 40A. Qual é a porcentagem de overlod que o controlador 1240 suporta?

    • @PowmrSolar
      @PowmrSolar  หลายเดือนก่อน

      Por favor leia as instruções abaixo.
      cdn.shopify.com/s/files/1/0746/0415/1079/files/POW-KEEPER-Series_User_Manual_bb3569ba-b8fb-44af-b705-ef13f9c0da9e.pdf?v=1686640659

  • @danielbituin4382
    @danielbituin4382 ปีที่แล้ว

    Please help how can i set my float votage into 12.6 only beacause im using 3s lithuim ion battery.thanks

    • @wzjiang856
      @wzjiang856 ปีที่แล้ว +1

      预设的电池类型的参数是默认的, 不能任意调节, 可以选 usr2 用户定义, 大部分参数可以调节.

  • @TonsTV13
    @TonsTV13 ปีที่แล้ว

    good day mam., LVD/under volatage protection settings that is ok for GEL 10.1?

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Yes, it's Ok.

    • @Jeffersonboncodin
      @Jeffersonboncodin 11 หลายเดือนก่อน

      What 10.1 low voltage disconnect? GEL is 50/50

    • @jabaguealfredo
      @jabaguealfredo 9 หลายเดือนก่อน

      you can set the lvd to 12.3 using the usermode 1, when you choose the gel type mode, you cannot configure it manually

  • @ferdoushrahman6802
    @ferdoushrahman6802 5 หลายเดือนก่อน +1

    I want to change the high voltage to 15 volts in lead acid batteries. But how?

    • @PowmrSolar
      @PowmrSolar  5 หลายเดือนก่อน

      Select USE for the battery type, and then adjust it yourself.

  • @lufemendes
    @lufemendes ปีที่แล้ว

    Hi, I'm having an issue with my Keeper 1230 controller. The display isn't cycling through the different screens like current, voltage, and temperature. Any advice on fixing this? Thanks!

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว +1

      Hi, kindly send your problems to this email: support@powmr.com

    • @luizhenriquemerhy1640
      @luizhenriquemerhy1640 ปีที่แล้ว +2

      É a versão do software instalado. O meu é U1.4 é também não fica trocando e os icones no display no LCD são diferentes dos que ficam mudando os dados, è igual ao deste video acima que também não muda .

    • @lufemendes
      @lufemendes ปีที่แล้ว

      @@luizhenriquemerhy1640 Valeu, amigo!

  • @patrickc.3185
    @patrickc.3185 ปีที่แล้ว

    Hi, I'm using the POW-Keeper 1220. I selected SLD in the controller because based on the manual, if you are using a Sealed Lead Acid Battery of 12V, you should select SLD. My problem is in the SCC, the LVD is set too low at 10.8V. How can I change it to 12.0V? I long press the MENU button while LVD is selected but nothing happens. I need to increase the LVD to protect my battery.

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Please change the battery type to USR1 or USR2 before setting it up. If SLD is set, the system will automatically default LVD to 10.8V and cannot be modified.

    • @patrickc.3185
      @patrickc.3185 ปีที่แล้ว

      @@PowmrSolar Thank you. I will try setting it on USR2 and let you know if it will be successful.

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      @@patrickc.3185 Okay.

  • @moesuki2810
    @moesuki2810 ปีที่แล้ว

    In a 24v load terminal system that supplies 24v, can it supply 12v power?

    • @aleksandersats9577
      @aleksandersats9577 11 หลายเดือนก่อน

      If you set your batteries to 24v then no. You will need a buck converter to convert that to 12v.

  • @Aurthermorgan02
    @Aurthermorgan02 6 หลายเดือนก่อน

    Hi... May I limit the ampere i want to charge the battery.... I want my battery will be charged at 5 amp and extra ampere, is it possible from user setting?

    • @PowmrSolar
      @PowmrSolar  6 หลายเดือนก่อน

      Nope, this cannot be set.

  • @ritchiegarcellano8382
    @ritchiegarcellano8382 ปีที่แล้ว

    Hello maam. Im already bought powkeeper 1230. Same as your MPPt. Can i ask?. How about reserved settings if long press the MENU,will shown 19.2 directly. Its ok for that. My battery is 12v system. Sealed Lead Acid battery

    • @amyliu5169
      @amyliu5169 ปีที่แล้ว

      Hi dear sir, could you tell me which setting parameter you are asking? (the charging voltage? or the battery type?) Let me have a check for you.

    • @ritchiegarcellano8382
      @ritchiegarcellano8382 ปีที่แล้ว

      The last settings that i have shown, no01 or reserved settings, or nevermind that settings, because if put press MENU 3s will shown, other settings

    • @wzjiang856
      @wzjiang856 ปีที่แล้ว

      this setting is for RS485 comunication baudrate, 19.2 means 19.2K , this fuction reserve for future only @@ritchiegarcellano8382

  • @jayveealvaro8518
    @jayveealvaro8518 ปีที่แล้ว

    hi im using powmr 1220. Im using GEL battery I set the mppt to gel but the LVD is too low at 10.8V cannot be change to 12.0V how can i change it to 12.0? thank you

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Please send your problems to this email: support@powmr.com

    • @Jeffersonboncodin
      @Jeffersonboncodin 11 หลายเดือนก่อน

      Me too.. the GEL type is 50/50 DOD.. 10.8V is too low.

    • @PowmrSolar
      @PowmrSolar  11 หลายเดือนก่อน

      @@Jeffersonboncodin Please send your problems to this email: support@powmr.com

  • @jaymarktalaboc4110
    @jaymarktalaboc4110 หลายเดือนก่อน

    I brought this model 3 days ago
    Powered FLD BAT 24AH 12V 200w pv
    and yesterday cumulated 17ah then i used 1 lamp 7 watts over night why the cumulated ah did not decrease. And to day it continue adding ah. As of now it has 20ah.

    • @PowmrSolar
      @PowmrSolar  หลายเดือนก่อน

      Please send it to this email: support@powmr.com.

  • @lexiengapngagap2752
    @lexiengapngagap2752 7 หลายเดือนก่อน

    how can you activate the two usb portals

    • @PowmrSolar
      @PowmrSolar  7 หลายเดือนก่อน

      The controller has an operation mode setting item, which can be set on the Ld4 interface.

  • @MaurizioCarrar
    @MaurizioCarrar หลายเดือนก่อน

    dear assistance, I'm having difficulty with the translation into Italian, can you show me step by step the configuration for a widely used 9 Ampere lead acid battery? I would like to recharge it up to 14.5 volts and cycles at 15 volts because it is very worn. Thank you, greetings from Italy

    • @PowmrSolar
      @PowmrSolar  หลายเดือนก่อน

      Please send it to this email: support@powmr.com. Our technical staff will check it for you.

  • @lufemendes
    @lufemendes ปีที่แล้ว

    Is this a MPPT or a PWM?

  • @bakalito4601
    @bakalito4601 ปีที่แล้ว

    What are the default values for 24v Gel Battery?

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว +1

      Equalized charging voltage: GEL: No
      Absorption charging voltage:GEL: 14.2
      Floating charging voltage:GEL, Lead acid flooded battery: 13.8
      Low voltage re-connection:GEL, Lead acid flooded battery: 12.6
      Low voltage disconnection:GEL, Lead acid flooded battery: 10.8

  • @mshah5325
    @mshah5325 ปีที่แล้ว

    Please tell the maximum DC load watts. thank you

  • @richkhalifha246
    @richkhalifha246 5 หลายเดือนก่อน

    Pls is this mppt or pwm

    • @PowmrSolar
      @PowmrSolar  5 หลายเดือนก่อน

      mppt.

  • @harrydelara413
    @harrydelara413 ปีที่แล้ว

    Hello,
    Can you help me? I have your product Powmr Keeper Mppt 20A, I am trying to change the Resume Charge to higher voltage like 13.6V but I am not able to set it. This is what I am doing.
    From Main Page > 3seconds Menu button > Resume Charge
    On Resume Charge page I am trying to press Menu for 3 seconds but nothing is happening.
    Battery type is already set to Usr1

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Please send your problems to this email: support@powmr.com

    • @harrydelara413
      @harrydelara413 ปีที่แล้ว

      ​@@PowmrSolarI already sent to support, no answer until now.

    • @harrydelara413
      @harrydelara413 ปีที่แล้ว

      ​@@PowmrSolar I'm good now. i used Usr2 instead. I cannot change parameters on Usr1

  • @markrichardmabalay6750
    @markrichardmabalay6750 ปีที่แล้ว

    Hello, how to set for 8s lifepo4?

    • @amyliu5169
      @amyliu5169 ปีที่แล้ว

      You can choose "USr 1"

  • @odeiocomunistas
    @odeiocomunistas 9 หลายเดือนก่อน

    I bought one of these and put it on a stationary 12v battery but it doesn't charge all the way, the battery doesn't last long and turns off the inverter, give me the settings for this type of battery please.

    • @PowmrSolar
      @PowmrSolar  9 หลายเดือนก่อน

      Please send your question to this email: support@powmr.com.

  • @sunethpriyankara3524
    @sunethpriyankara3524 7 หลายเดือนก่อน

    hi ! I have powmr powkeeper mppt 1220 controller Firmware version v1.7 . i have problem with this controller. i used 12v LiPO4 battery pack. battery is normaly charging ok. but after few hours battery fully charged the controller stoped charging. and i using the battey in day time the battery just keeps going drain and the controller doesn't charge the battery no matter how much sunlight there is.
    There is no such problem with my other controllers. I have a powmr mppt 60A controller, Even after the battery was fully charged during the day. The amount of amperes obtained from the battery is not reduced by the battery and is given from the panels through the charging controller. Now this 1220mppt after fully charging it cut off the solar panels and do not give any output to useing load . Then in the evening, the battery is half depleted. The battery will not be left to use at night.. my english is not good butI hope you understand. how can i fix this. thanks

    • @PowmrSolar
      @PowmrSolar  7 หลายเดือนก่อน +1

      please send your problem to this email: support@powmr.com. Our technical staff will handle it for you.

  • @danielbituin4382
    @danielbituin4382 ปีที่แล้ว

    How can I set up 40A mppt for 3s lithuim battery?I can't see set the float voltage at 12.6

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, kindly send your problems to this email: support@powmr.com

  • @alanpc16
    @alanpc16 8 หลายเดือนก่อน

    Tenho uma dúvida.... quando ele entra no modo mppt em 12v qual é a voltagem mínima dos painéis para que ele entra no modo mppt.
    Meu sistema é 12v duas placa de 155w em paralelo e ele não arma o modo mppt é o 1230

    • @PowmrSolar
      @PowmrSolar  8 หลายเดือนก่อน

      For 12v system: the voltage range is 12V-75V, Max. Input Power: 390w.

    • @eltonveras
      @eltonveras 8 หลายเดือนก่อน

      Eu acredito que você tem que colocar as duas placas em série para o mppt entrar em ação. Boa sorte.

  • @maheshindrasingha5923
    @maheshindrasingha5923 ปีที่แล้ว

    Can I use 7s Lithium-ion battery packs(18650) with 250w solar panels(VMP 30.3v)(voc 38v)?

  • @MdSumon-ii9zr
    @MdSumon-ii9zr 6 หลายเดือนก่อน

    How to enable equalization mode?

    • @PowmrSolar
      @PowmrSolar  6 หลายเดือนก่อน +1

      Automatic equalization every 28 days

  • @szkarlatny_pumpernikiel
    @szkarlatny_pumpernikiel 9 หลายเดือนก่อน +1

    Hello, to the refreshed product should attach a new manual. I in my product got the old one and it caused me no small problem.
    I also have reservations about the menu on the display, it is so terribly unintuitive until a person is pissed off how to touch it.
    It is user unfriendly!😤

    • @PowmrSolar
      @PowmrSolar  9 หลายเดือนก่อน

      Hi, sorry for the inconvenience. Please send your questions to this email: support@powmr.com

  • @mohammadniaz1986
    @mohammadniaz1986 7 หลายเดือนก่อน

    I can use 40 amp mppt for my 280 ah tubleal bettery

    • @PowmrSolar
      @PowmrSolar  7 หลายเดือนก่อน

      Yes.

  • @mostiboysvlog5695
    @mostiboysvlog5695 ปีที่แล้ว

    How to set float voltage mine is maintain to 13.8 for Lifepo4 battery

    • @amyliu5169
      @amyliu5169 ปีที่แล้ว

      Hi, before you set Float votage, you need to set your battery type "US r1", then set Constant charge voltage and Absorption charge voltage first. Keep the Constant voltage and Absorption voltage are higher than Float votage.

    • @amyliu5169
      @amyliu5169 ปีที่แล้ว

      When you see the interface you want to change the set or parameter, you can long press the "up" button for over 3 seconds, then press "up" or "down" to select the parameter you want to choose. After you selected the parameter you need, long press "up" button again to save the setting selection.

  • @01lovemusic01
    @01lovemusic01 ปีที่แล้ว

    No option to see PV voltage?

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      This video is not connected to PV. You can see it directly after connecting to the PV.

    • @amyliu5169
      @amyliu5169 ปีที่แล้ว

      Hi, have you bought the Keeper 1240?@NeverMind-pk4wz

  • @Jayromemagtipon07
    @Jayromemagtipon07 ปีที่แล้ว

    And at LVD. Its says 9v cutoff voltage. But i want to increase the LVD to 11.1 or 3.7v per cell. But it can't edit. Its off. How. Can i turn it on to customize LVD 3s Lipo battery. Please help

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, please send your problems to this email: suppoort@powmr.com

  • @allanenopiaae
    @allanenopiaae 11 หลายเดือนก่อน

    i use lifepo4 battery and choose setting 4:3.2v..my problem is..error when the voltage are 14v when charging

    • @PowmrSolar
      @PowmrSolar  11 หลายเดือนก่อน

      please send your problems to this email: support@powmr.com.

  • @johncarlobernardo866
    @johncarlobernardo866 ปีที่แล้ว

    how to see PV WATTAGE OUTPUT? IN THE NEW CONTROLLER

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      HI, can't see the PV Wattage directly, but you can see the volts and amperes.

  • @okpalamichael4162
    @okpalamichael4162 ปีที่แล้ว

    How can i set the charge controller for 6S (3.7v 18650 lithium battery) lithium battery? Pls reply ASAP

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว +1

      You can set USEr1 or USEr2.

  • @eltonveras
    @eltonveras 8 หลายเดือนก่อน

    Eu tenho um 1230 com a versão 1.4. Como atualizar para a versão 1.7?

  • @kmrubel308
    @kmrubel308 ปีที่แล้ว

    What is the way to reset Please tell me a little...

    • @amyliu5169
      @amyliu5169 ปีที่แล้ว

      Hi, there is no reset setting selection on the LCD display.

    • @kmrubel308
      @kmrubel308 ปีที่แล้ว

      Thanks for the reply, it would be nice to have a restart system...

    • @kmrubel308
      @kmrubel308 ปีที่แล้ว

      The product is very good...

  • @ThanWin-nn9un
    @ThanWin-nn9un 8 หลายเดือนก่อน

    I am using POW MR, POW Keeper 1240, SOLAR CHARGE CONTROOLLER.
    The box is showing 'ERRO' and how I can solve this error, please help.

    • @PowmrSolar
      @PowmrSolar  8 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com. Our technical staff will handle it for you.

  • @cenonvillanueva3045
    @cenonvillanueva3045 ปีที่แล้ว

    How to set at low voltage disconnect for lead acid battery

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, please send your problems to this email: support@powmr.com.

    • @cenonvillanueva3045
      @cenonvillanueva3045 ปีที่แล้ว

      @@PowmrSolar the lvd of scc is 10.8 , i change of 12.9 but i se the but 10.8 is dont blink i press for 3 second or long press botton up to menu

  • @koioskobesarmiento9521
    @koioskobesarmiento9521 6 หลายเดือนก่อน

    how to nake the display scroll?

  • @asifsialvi3590
    @asifsialvi3590 2 หลายเดือนก่อน

    I have ordered a 40 amp mppt, please send a video of its setting in urdu.

    • @PowmrSolar
      @PowmrSolar  2 หลายเดือนก่อน

      Currently only in English. You can convert the subtitles into the language you want.

  • @charlesgayon8738
    @charlesgayon8738 ปีที่แล้ว

    Why cant i change the parameters for my batery

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      What parameters?

    • @charlesgayon8738
      @charlesgayon8738 ปีที่แล้ว

      @@PowmrSolar the equalization charge the resume charge constant voltage charge and the float charge

    • @charlesgayon8738
      @charlesgayon8738 ปีที่แล้ว

      Im using lifepo4

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      @@charlesgayon8738 Is your battery type set to usr1 or usr2?

    • @charlesgayon8738
      @charlesgayon8738 ปีที่แล้ว

      4-3.2

  • @a.arestovich
    @a.arestovich 8 หลายเดือนก่อน

    Is it possible to connect the 220 inverter to the controller load instead of the battery?

    • @PowmrSolar
      @PowmrSolar  8 หลายเดือนก่อน

      You can only connect to the battery.

  • @marklenrodolfo5030
    @marklenrodolfo5030 ปีที่แล้ว

    What is mean E-11

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว +2

      Hi, E11: 12V system battery low voltage protection.

  • @marklenrodolfo5030
    @marklenrodolfo5030 ปีที่แล้ว

    How can i reset my powmr mppt same as your video. Becouse my unit is charge at 12.8 in daytime but in 6pm around the voltage shuld drop to 11.9

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, kindly send your problems to this email: support@powmr.com.

  • @terk7121
    @terk7121 ปีที่แล้ว

    The ! symbol always shows what does that mean? what I did wrong.

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว +1

      Hi, are there any other fault codes? Only ! symbol?

    • @terk7121
      @terk7121 ปีที่แล้ว +3

      @@PowmrSolar Yes and i also cann't set any parameter when i press the button.

    • @moesuki2810
      @moesuki2810 ปีที่แล้ว +2

      ไม่สามารถตัเงค่า พารามิเตอร์ได้เช่นกัน

    • @poppybusiness
      @poppybusiness ปีที่แล้ว +1

      yes, me too can't set up

    • @Jeffersonboncodin
      @Jeffersonboncodin 11 หลายเดือนก่อน

      Me too .. complected new version 😢

  • @diedampfbrasse98
    @diedampfbrasse98 8 หลายเดือนก่อน

    Update your user manual downloads!!!!
    also would be nice to allow setting the Li capacity in exact values instead of just giving 5AH steps

  • @AzizulSarmin
    @AzizulSarmin ปีที่แล้ว

    My dear sister...My have 30A PowMr Mppt Soler charge controller...
    But I Don't no setting ...
    You halp me ...

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, kindly send you problems to this email: support@powmr.com

  • @put_istine
    @put_istine 3 หลายเดือนก่อน

    Seems like a good controller. However, the interface is not very customizable and a bit confusing.
    For example, there is no need for 4 LD options. Can be easily set: [24 h] for constant output, [0 h] at night, that is. it works when the panels are not charging and vice versa and [1-23h] time how long the output works when the panels are not working, [-1h] reverse mode (while the panels are charging). And so instead of 6 setting options, here we have only one parameter that covers all 6 options.

  • @guilhermesilva9280
    @guilhermesilva9280 11 หลายเดือนก่อน

    Gostaria de um tradução para o português Brasil, estou com dificuldade para configurar o meu pow keeper 1230.

    • @PowmrSolar
      @PowmrSolar  11 หลายเดือนก่อน

      Hi, please send your problem to this email: support@powmr.com

  • @ryuhayabusa3510
    @ryuhayabusa3510 7 หลายเดือนก่อน

    pano mag set up ung latest mppt

    • @PowmrSolar
      @PowmrSolar  7 หลายเดือนก่อน

      what the latest mppt?

  • @maheshindrasingha5923
    @maheshindrasingha5923 ปีที่แล้ว

    Hello ..can I use 7s Li-ion battery packs with this ?

  • @lucianotavares9378
    @lucianotavares9378 11 หลายเดือนก่อน

    Preciso de um em português

    • @PowmrSolar
      @PowmrSolar  11 หลายเดือนก่อน

      Hi, this model(POW-Keeper1220)?

  • @josephaltona724
    @josephaltona724 ปีที่แล้ว

    Pa send nga po ng vedio yong new version ng mppt30amper kc herap ng settings nya po

  • @andersonaraujo5333
    @andersonaraujo5333 ปีที่แล้ว +1

    wow, this version is very complicated, please go back to the previous version, this one is very bad.

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      please send your problems to this email: support@powmr.com.

    • @Jeffersonboncodin
      @Jeffersonboncodin 11 หลายเดือนก่อน

      Yeah

  • @rkradhakrishna5612
    @rkradhakrishna5612 10 หลายเดือนก่อน

    It is better to give video in Bengali for Bengali

  • @royfitrah8507
    @royfitrah8507 ปีที่แล้ว

    New version controller

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      New version Keeper.

    • @royfitrah8507
      @royfitrah8507 ปีที่แล้ว

      I like this pow keeper ❤

  • @8126926
    @8126926 ปีที่แล้ว

    keep your finger off the controller until you are actually ready to press a button. you are confusing the crap out of me.

  • @MyintSwe-h3z
    @MyintSwe-h3z 6 หลายเดือนก่อน

    မြန်မာလိုရှင်းပြပါလားခင်ဗျာ

  • @LAMBESEWU
    @LAMBESEWU หลายเดือนก่อน

    Helo, how to set for 4s lifepo4 whit BMS system?

    • @PowmrSolar
      @PowmrSolar  หลายเดือนก่อน

      Please send it to this email: support@powmr.com.

  • @eumesmo-kd1tr
    @eumesmo-kd1tr ปีที่แล้ว

    What are the default values for 24v LiFePO4 Battery?

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Equalized charging voltage
      Maintenance-fee lead acid battery: 14.6V;
      GEL: No; Lead acid flooded battery: 14.8
      Absorption charging voltage
      Maintenance-fee lead acid battery: 14.4V;
      GEL: 14.2; Lead acid flooded battery: 14.6
      Floating charging voltage
      Maintenance-fee lead acid battery,
      GEL, Lead acid flooded battery: 13.8
      Low voltage re-connection
      (LVR)
      Maintenance-fee lead acid battery,
      GEL, Lead acid flooded battery: 12.6
      Low voltage disconnection
      (LVD)
      Maintenance-fee lead acid battery,
      GEL, Lead acid flooded battery: 10.8

    • @eumesmo-kd1tr
      @eumesmo-kd1tr ปีที่แล้ว

      @@PowmrSolar thanks a lot but what about LiFePo4 battery at 24 V , BR

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      @@eumesmo-kd1tr Generally, you can find the specific reference value of the battery in your lithium battery manual. Then set the battery type to USE on the controller, and you can customize the lithium battery parameters according to the reference values ​​in your battery manual.

    • @eumesmo-kd1tr
      @eumesmo-kd1tr ปีที่แล้ว

      @@PowmrSolar yes thanks, i was looking for the values and how to change it, but now i could find it, now i will connect with my other controller in parallel with the same values than my epever controller BR

  • @fnfindingnature
    @fnfindingnature ปีที่แล้ว

    I have pow keeper 1220 new version but not changing display data automatically in stanby. Like battery voltage, pv voltage, load etc. Not displaying automatically frequently.

    • @PowmrSolar
      @PowmrSolar  ปีที่แล้ว

      Hi, please send your problems to this email: support@powmr.com

  • @sclare5514
    @sclare5514 3 หลายเดือนก่อน

    How do you reset the system ?
    It's not charging my lithium ion battery more than 13.6 v even though solar input is 23v Why?

    • @PowmrSolar
      @PowmrSolar  3 หลายเดือนก่อน

      Please send your problem to this email: support@powmr.com.