Hikvision Access Control Solution How to Guide on iVMS-4200

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ก.ย. 2024

ความคิดเห็น • 58

  • @DVSLTD
    @DVSLTD  6 ปีที่แล้ว

    Be sure to subscribe to our channel and turn the bell on to be notified when we release a new video

    • @chiwale
      @chiwale 5 ปีที่แล้ว

      hi. do i need a dedicated PC at the clients location or can i use my personal pc to set it up and just walk with my laptop when i need to do maintenance

  • @benjaminczarny
    @benjaminczarny 4 ปีที่แล้ว +1

    Your videos have been super helpful! I do have a question - At 22:22 of this video your search results display the card details for Enter/Exit logs. Running the latest version of iVMS-4200 as of this post with all features installed, the details in the Event Center do not show any card details. The only way I see this is the Monitoring tab, but if the app closes for any reason, all of that data is lost. Even emailed events are generic, no indication of the card or person. Where can I find a log of who entered, instead of just that an entry occurred?

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      Hi bejamin and thanks for the kind words, can you verify the 4200 version please?, also under event centre and search events , if you change the search option to be access control and then select that device does that then enhance the log for you?

  • @vRxUniQueZ
    @vRxUniQueZ 2 ปีที่แล้ว

    hi mate, is there anyway of controlling the two different door lock outputs (in the control panel) using just one card reader/keypad? cheers

  • @dynamicbusinesssystems67
    @dynamicbusinesssystems67 4 ปีที่แล้ว +1

    Hi,
    Would i be able to pull a report or take a quick look at who is in the building ? SO if i go to security where this IVMS is installed and they can eisily tell me there are 20 people in the building and who they are?

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      Hi , you can see the data but its not as easy as showing “ only in building now “ option, for this we have it in HIK-Central , I will look to see if I can find a cheat inside 4200 to make it easier

  • @firdousnaeeminam2043
    @firdousnaeeminam2043 2 ปีที่แล้ว

    Awesome ♥️

  • @roamey
    @roamey 4 ปีที่แล้ว

    I have 750 mifare 1kb cards to add. I tried to add them via an excel doc and import it. No joy. The cards have batch numbers on them that can be added to other access systems but don’t seem to have any significance to the Hik system. If I add the cards one by one via a reader they work as the mifare number is different. Is there a way to Expedite this process. Does the wiegand/485 wiring make a difference. Thanks

  • @gjenck
    @gjenck 3 ปีที่แล้ว

    how yo teach the reader to read the card ,you can see the reader in ivms4200 ? i have connected a ds-k1201mf fingerprint/card reader to ds-kv8413-wme1 4post outdoor intercom , and i cant even figure out where and how can i see the reader connected on rs485 ! so the led on reader shows that the rs485 connection is ok is constant red .
    Any clue ???

  • @tryingonly
    @tryingonly 5 ปีที่แล้ว +1

    Hi there. Is there a http command or App function to open the door when visitors press the bell?

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว

      Yes, with in the app there is an open door function

  • @adeoyeoyekanmi4634
    @adeoyeoyekanmi4634 4 ปีที่แล้ว +1

    Hi,
    Is it possible to connect about 10 fingerprint access control device to a Network Access Controller DS-K2602-G terminal ?.... if it is , plz explain.

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      Hi , the max we do is a 4 door ACU , if you have Read in and Read out then that is 8 readers, if you just want 10 single doors with Fingerprint then you can use 2 x 4 door , + 1 x 2 door ACU and wire the Belden cable from the reader location to the ACU reader input , does this make sense?

  • @Walterz930
    @Walterz930 4 ปีที่แล้ว +1

    Hi Dave is there any way to link this to the main door and use it for clock on shift if you show your card outside and then when you use the inside one it then clocks you off shift

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      Hi , yes using 4200 or HIK-Central we can use the Time & Attendance function to do the clocking in & out function , 😊

    • @Walterz930
      @Walterz930 4 ปีที่แล้ว

      Thank you for that information it’s just as as I am going to be looking at bigger install contracts and this might be useful for some of them that I am looking at

  • @mohammedjasheer8308
    @mohammedjasheer8308 6 ปีที่แล้ว +1

    Hi Dave
    There are RS-485 connections on the left side and bottom also. You connected both readers on bottom connection. What is the difference between both connections?

    • @DVSLTD
      @DVSLTD  6 ปีที่แล้ว +1

      correct there are 2 types of RS-485 , the reader Rs-485 connection is already made of at the bottom connectors , as well as having another set on the top left, the bottom uplink RS-485 is to link controller - to - controller 😊

    • @mohammedjasheer8308
      @mohammedjasheer8308 6 ปีที่แล้ว

      @@DVSLTD Thanks

  • @manoelanjos
    @manoelanjos 5 ปีที่แล้ว +1

    Hi Dear, for configure the access control device under iVMS-4200, I need the software HikCentral ( software manager) ?

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว

      Hey , you can configure and use up to 64 doors in IVMS-4200, past this we need to use HIK-Central , but IVMS-4200 is still very powerful for access control so you don’t need HIK-Central specifically

  • @multimediaind1384
    @multimediaind1384 4 ปีที่แล้ว +1

    Bro I have problems door relay timing I need low time relayon

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      what time do you need ? it depends on the product being used but 5 secs is sometimes the lowest , later models and 4200 allow lower setting

  • @JackyBoogle
    @JackyBoogle 5 ปีที่แล้ว +1

    How long is the data kept on the event log? How far back can you search?

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว

      It depends on the setting , it will follow the NVR storage days also

  • @stevanzikic150
    @stevanzikic150 4 ปีที่แล้ว +1

    Hello there! I have one question about iVMS-4200, can we add and remove users from two different computers and different network or everything needed to be done from one place and one computer??

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว +1

      Hi , as IVMS-4200 is run as single instance its done from the same place , if multi stations are required I would use HIK-Central and use the client on each PC needed, this is licensed but will achieve what you want 😊

    • @justinkinsey5517
      @justinkinsey5517 3 ปีที่แล้ว

      @@DVSLTD Hey David if using iVMS would I still need a NVR

  • @kymjosef
    @kymjosef 5 ปีที่แล้ว +1

    We installed time attendance, but the pc can not generate any reports, but the reports are available manually form the device. I have tried with 3pcs but no success, what could be the issue

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว

      Hi , this could be anything , what version of IVMS-4200 are you using ??

    • @kymjosef
      @kymjosef 5 ปีที่แล้ว

      @@DVSLTD the issue was the pc I had used to register the devices, I did a factory reset and did a clean installation on sever, for easy remote access

  • @Catawbasecurity
    @Catawbasecurity 4 ปีที่แล้ว

    Is there any kind of mobile access available to control this? I see that Hik Connect does not work...

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      not yet no , only if using HIK-Central VMS and the mobile app to give some mobile functions but then the cost is more due to licensing

  • @shaunsmith2763
    @shaunsmith2763 4 ปีที่แล้ว +1

    How would you wire a panic bar into this and then change it when you swipe to shunt the alarm from going off? Cheers

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      Hi Shaun , sorry this might sound a stupid question but not sure I understand , the panic bar would be wired in as an alarm circuit , assume you want to be able to isolate this alarm ?

    • @shaunsmith2763
      @shaunsmith2763 4 ปีที่แล้ว +1

      @@DVSLTD correct. I wired into the alarm area and then on 4200 changed the alarm settings to delay 45 seconds but it is still sounding one the door contact is broken. Any advice to isolate it out and allow for the delay?
      Thanks for the super fast response. I love the videos!

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      @@shaunsmith2763 Ah I see, and thanks for the feedback 😊 ,let me test it , is it the terminal in the video or the ACU unit ~( DS-K260x)

    • @shaunsmith2763
      @shaunsmith2763 4 ปีที่แล้ว

      @@DVSLTD acute unit

  • @KyPalmo
    @KyPalmo 5 ปีที่แล้ว +1

    What is meant by the term 'wegun' (sorry for the phonetic spelling)

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว +1

      The term Wigand or Wiegand as people do spell it that way , this is a connection protocol type used mainly in access control systems ,its D1 and D0 connection type and carries the data between a reader and the reader input on the controller , it also is a standard of say 26Bit , 32Bit , 37 Bit etc and acts a little like ONVIF in the CCTV world where readers from other manufacturers could be used on other controllers, hope this helps

  • @VAPlays25
    @VAPlays25 4 ปีที่แล้ว +1

    theres no one appearing in my Access Control Point/Device. what do i need to do?

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      Hi , without seeing the setup it would be hard to see what the exact issue is sorry, assuming you have added the devices and the person records and then applied the settings to the devices ?

  • @steven7en250
    @steven7en250 4 ปีที่แล้ว +1

    How to overtime setting 4200AC. It's never appear on my report. It's show 0

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      Hi, are you meaning the Time and Attendance function?

  • @prashilnand2595
    @prashilnand2595 5 ปีที่แล้ว +1

    can it support a biometric lock to open doors?

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว

      We can open a lock via biometric but don’t have all in one biometric lock currently

  • @AxionGuy08
    @AxionGuy08 4 ปีที่แล้ว +1

    Is there a way to unlock doors from a mobile app?

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      On the terminals yes, do you want to do it on the ACU also ?

    • @AxionGuy08
      @AxionGuy08 4 ปีที่แล้ว +1

      @@DVSLTD Yes from the ACU. Let's say for example a business owner wants to open the door for an employee at the business but he/she is not there. Can they open the ivms mobile app and unlock a specific door remotely? I was unable to find this functionality.

    • @DVSLTD
      @DVSLTD  4 ปีที่แล้ว

      @@AxionGuy08 Not from the ACU , I can’t think of a way , let me check

  • @randomVidsandMusic
    @randomVidsandMusic 4 ปีที่แล้ว

    Hi,i managed to installed everything and it was running fine for 3 weeks,but today i get alot of users failed to unlock door and when i check the monitor section it stated "invalid Duration" at the description.

    • @wesleygilbert8301
      @wesleygilbert8301 4 ปีที่แล้ว

      did you ever find the solution to "invalid duration"?

  • @willesonsouza683
    @willesonsouza683 5 ปีที่แล้ว

    I have a DS-K1T804EF terminal and I am using a secure port module DS-K2M060, I am not able to communicate with the 804 when the button is opened, it does not unlock the lock, nor when the biometrics in the 804 is used, the port is released, I'm using an electric lock, could it be the dip-switch? How to read the dip-Switch
    thank you

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว

      sorry I have been away , assume this is fixed now??

  • @idphoto4587
    @idphoto4587 5 ปีที่แล้ว +1

    i cant find time and attendance video

    • @DVSLTD
      @DVSLTD  5 ปีที่แล้ว +1

      Correct I have not published this yet , we plan to do one in the coming weeks