STAAD Pro CONNECT Edition Structural Analysis by Equivalent Static Method

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ก.พ. 2025

ความคิดเห็น • 14

  • @babydas1989
    @babydas1989 6 ปีที่แล้ว +1

    Very good and well done

  • @BishalDasOfficial
    @BishalDasOfficial 6 ปีที่แล้ว +1

    Very nice..keep it up..

  • @Naik1920
    @Naik1920 6 ปีที่แล้ว

    Very good professor , I request u to demonstrate response spectrum method

    • @satabdidas9784
      @satabdidas9784 6 ปีที่แล้ว

      Sure.. Thank you for your suggestion!!

    • @Naik1920
      @Naik1920 6 ปีที่แล้ว

      Mam which method is most safetest method? For taller buildings, our codes are suggesting for an dynamic one, if we do by static method then what will happen mam?

    • @satabdidas9784
      @satabdidas9784 6 ปีที่แล้ว +2

      @@Naik1920 As per IS 1893: 2016, static method is applicable only if the building is in zone II with regular geometry, when time period is less than 0.4 secs and the building height is less than 15m . If not, the code suggests to use dynamic method of analysis.

    • @Naik1920
      @Naik1920 6 ปีที่แล้ว +1

      Thanks you professor

  • @ronnie9096
    @ronnie9096 4 ปีที่แล้ว +1

    Why floor weight is 6.75 KN/m2 (i.e DL+LL=3.75+3=6.75) without any reduction in imposed load i.e 25% of 3KN/m2=0.75KN/m2.
    mentioned in table 10 of IS 1893-part 1-2016. isn't it supposed to be 3.75+.25x3=4.5 Floor weight. correct me if I am wrong.

  • @rajanv.m.8136
    @rajanv.m.8136 5 ปีที่แล้ว

    In this videa i have seen three aspects. Whether for this model equivalent static method is applicable or not. For only zone II itis applicable. Another point is whether y direction design vertical coefficient is applied or not. Whether cracked moment of inertia is applicable or not for this method.

  • @atharuddin9594
    @atharuddin9594 4 ปีที่แล้ว

    Madam how to resolve syntax error in SEM method

  • @designcivil5229
    @designcivil5229 6 ปีที่แล้ว

    but i m unable to get any code in seismic definition what is the problem, i m using staad pro CE v22

    • @satabdidas9784
      @satabdidas9784 6 ปีที่แล้ว

      Please follow the steps below to fix the issue
      1. Exit all running sessions of STAAD.Pro application.
      2. Delete the folder C:\Users\\AppData\Local\Bentley\Engineering\STAAD.Pro CONNECT Edition\Default. Note that is to be replaced by actual user profile name.
      3. Restart STAAD.Pro application.
      Thanks!

  • @AtulEngineer
    @AtulEngineer 6 ปีที่แล้ว

    Why wall load has not been considered ?

    • @satabdidas9784
      @satabdidas9784 6 ปีที่แล้ว +1

      Here only the process of adding loads has been shown. You can definitely add the wall load as member load.