IACS Water Level Float Switch Kits - Instructions & Wiring How To with diagrams FK1

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 มิ.ย. 2024
  • Here is our quick start guide to using our standard float switch kits such as (FK1, FK2, FK3 etc...) It will show you some simple wiring options and talk you though how to wire it, and what not to do. We will create a basic circuit using a lamp / beacon and show some tips and instructions to get the kit up and running, safer and more flexible than a switch alone.
    We have recently released our new Float Kit X-Series which has many more protection features as well as integrated 'intelligence', the board actually 'thinks' and mades decisions about whether or not to trigger the pump so it can protect your pump or solenoid from waves and ripples in the water that can cause many devices to fail. They also feature high low switches for more control over your installation. Check out our other videos if you are interested or see links below.
    Our products are still available on Amazon (fast option) or from our website.
    The easiest way to BUY OUR KITS is to visit our AMAZON shop:
    Float Kit 1 (Featured in this video) in 12V DC:
    CURRENTLY UNAVAILABLE - COMING SOON
    Float Kit X-Series Kit 1 (Intelligent Automatic Tank Refill Controller with 2 Switches):
    LINK amzn.eu/d/75Qadxj
    Float Kit X-Series Kit 2 - Single Point Pump & Solenoid control and protection with Ripple Correction Code - AVAILABLE NOW ON AMAZON UK
    LINK amzn.eu/d/gNQkZEm
    Float Kit X-Series Kit 3 - Automatic Tank Drain / Emptying Controller -
    AVAILABLE NOW ON AMAZON UK
    LINK Coming Soon - Out of Stock
    IACS Electronics.com Shop Links (These have copies of Datasheets & Instructions):
    Float Kit 1 - on our website:
    iacselectronics.com/product/fk1/
    Float Kit 5 (Right angle stainless steel barrel switch):
    iacselectronics.com/product/fk5/
    You can find datasheets and ordering information on our website iacselectronics.com
    Timestamps:
    0:00 Introduction
    0:58 Safety Notice
    2:00 Installation
    3:38 Float Switch Mounting
    4:26 Mounting Suggestions
    5:10 Wiring Instructions and Wiring Diagram
    9:15 Testing
    9:36 Other Voltage Wiring including Mains Voltage (110/230V AC)
    10:06 How to Invert the Logic/Switch State.
    10:50 Final Notes and Conclusion
    11:20 Discount Coupon Code
    #floatswitch #machinerysolutions #diy #experiment #ai #aquaponia #originaldesigns #madeinbritain #aquarium #ai #aquaponic #levelsensor #pumpcontroller #tankcontroller #watertank #topup #fypシ #fyp #homesolution #industrialautomation #electronics #newvideo #ai #liquidsensor #watersolutions #solenoid #bestfloatswitcth #waterpumpprotection #breweries #firesafety #offgrid #12vdc
    This video contains music provided by a third party:
    Courage and Willpower by Keys of Moon | / keysofmoon
    Music promoted by www.free-stock-music.com
    Attribution 4.0 International (CC BY 4.0)
    creativecommons.org/licenses/...
    Orion by Serge Narcissoff | / sergenarcissoff
    Music promoted by www.free-stock-music.com
    Creative Commons Attribution-ShareAlike 3.0 Unported
    creativecommons.org/licenses/...
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 47

  • @Emelia-cr3js
    @Emelia-cr3js หลายเดือนก่อน +2

    HI CAN YOU HELP ME HERE. I have a big problem with a reservoir for animal feed. It periodically gets filled from a silo which is very high up and so the water comes down from such a high pressure so it causes waves in my water tank. Any float switch I tried has flicked on and off rapidly. I have had two solenoids burn out and I've tried timer switches already, any ideas????

    • @MarkRawlings-md9ci
      @MarkRawlings-md9ci หลายเดือนก่อน +1

      Hey mate. I've got the same problem. We stuck the float switch in the tube in the end but it is far from reliable.

    • @IACSElectronics
      @IACSElectronics  หลายเดือนก่อน

      Sorry dear you've been having problems with your tank. We have in fact been filming a video about things like this. Your problem is quite common. I will send you some links. th-cam.com/video/355QKx36WCU/w-d-xo.htmlfeature=shared
      IACS FLOAT KIT X-Series Kit 2 - Intelligent Pump and Solenoid Protection and Control System: Ripple Correction Code amzn.eu/d/hrCHjFg
      If you have any further questions please don't hesitate to get in touch!

  • @sumitkantsardana
    @sumitkantsardana 3 ปีที่แล้ว +2

    Very Nice

  • @IACSElectronics
    @IACSElectronics  4 ปีที่แล้ว +2

    If you have any requests, ideas or suggestions to improve our products or videos - please let us know.

    • @peshrawahmadebrahem991
      @peshrawahmadebrahem991 4 ปีที่แล้ว

      Can I run the board on a 100 amp and 12 volt battery?

    • @jeheildelfin355
      @jeheildelfin355 3 ปีที่แล้ว

      can the switch trigger an sms message using an arduino and a gsm module?

    • @IACSElectronics
      @IACSElectronics  ปีที่แล้ว

      @@jeheildelfin355 Hello, in theory yes it could. We don't supply / build GSM or SMS capable boards at the present time but you could probably link a switch to an arduino and create a custom sketch with a SIM / GSM add-on board (shield).

  • @kylecarson2395
    @kylecarson2395 3 ปีที่แล้ว +1

    This kit would work with an optical sensor too right? It is just checking to see if the connection is open or closed.

    • @IACSElectronics
      @IACSElectronics  3 ปีที่แล้ว

      Hello, in theory all you have to do is complete the circuit for the float switch. When the circuit is closed, the relay will activate. We have other versions of this kit including twin float switch arrangements, ripple / wave correction and more, as well as timed and contactless versions. We have other boards designed to work with NPN sensors, if you would like me to look at a specific model of sensor please feel free to send me a link to an item or datasheet and I can advise.

  • @adameidimtas3354
    @adameidimtas3354 3 ปีที่แล้ว +1

    Hello. I am the one who inquired via eBay about a timer float switch here in the usa

    • @IACSElectronics
      @IACSElectronics  3 ปีที่แล้ว

      Hello, good to hear from you. We can certainly help with your requirements for a hydroponics system, we can produce a float switch kit with integrated adjustable timer to water once every for example 8 hours for 10 minutes each time but to make it easier to adjust, it may be best if you used another 'off the shelf' timer for the watering cycle and routed it through our baords and float switches to control and monitor the tank levels and operate the pumps / valves you may need - if you would like to contact us direct you can on services@iacselectronics.com and we can send you some further information & options.

  • @vishrutnavalkar424
    @vishrutnavalkar424 3 ปีที่แล้ว +1

    Hi IACS Electronics
    ,
    Scenario:
    Considering I have a 10ft tank and I want to install 2 such switches; 1 at top and 1 at bottom. If I don't want to drill holes in my tanks body to fit these, I had a alternative idea of using a non-corrosive material strip of 10ft having the 2 switches fitted to it at required heights(top and bottom).
    Now coming to my question, if I put this setup of the strip into my tank my bottom switch would be completely submerged into the water and probably my top switch also. So is it okay if they are completely inside the water??? Any possible failure or issue it might cause???

    • @IACSElectronics
      @IACSElectronics  3 ปีที่แล้ว

      Hello, good question. In theory yes you could mount them on a strip and then submerged them completely but there may be a tidier and more reliable way of achieving your goal. If you do wish to Mount them in such a way I recommend coating the back in HA6 RTV silicone sealant but you may overall be better off either using a long shaft stainless steel barrel switch (or pair of) alternatively a contactless float switch sensor which would be stuck to the side of the tank with foam or adhesive. Another thing to consider is if you are planning to use two float switches to either co-ordinate filling or draining of a tank, you may be better off using one of our twin float switch control kits rather than two singles. If you would be happy to share more about what you're trying to achieve using the switches and what the tank is for, I would be happy to advise further.

    • @vishrutnavalkar424
      @vishrutnavalkar424 3 ปีที่แล้ว

      @@IACSElectronics The main goal is to setup these switches inside my domestic water tank. I have one underground tank(main tank) from which water is pulled into another tanks situated on terrace(drinking water).
      Since its for drinking I am trying to avoid adhesive's or any sticky solutions to be used inside the tank. More over I am looking for a low/no maintenance electronic sensor which should not be affected by water conditions(salts, PH values, etc. )as it would be under water for years.
      The output of this sensor would be given to the controller which will then automatically turn ON/OFF the ground pump. If possible, can you share product reference links so that I can check the functioning and see if its usable in my case.

  • @MegaKbyrne
    @MegaKbyrne 2 ปีที่แล้ว +1

    Can you supply a link to a twin float switch kit?

    • @IACSElectronics
      @IACSElectronics  ปีที่แล้ว

      Hello, sorry for our slow reply. We have designed a twin switch kit which we will be listing shortly.

  • @ravikantkumar6983
    @ravikantkumar6983 2 ปีที่แล้ว +1

    Can we use of this device in pit which is motor up and down ??

    • @IACSElectronics
      @IACSElectronics  หลายเดือนก่อน

      If you would like to use are float switch to operate a motor, you will need to determine the starting and stopping position of the motor. You can get linear actuators, which is a bit like a robotic piston. They can be used to move things up and down. We have had kids like this used to open and close windows by combining them with a linear actuator. However you may need a secondary timer or switch to make sure the motor doesn't move it too far. Please feel free to follow up with additional information about your project. We would be happy to advise.

  • @learningtolivewithhumans1859
    @learningtolivewithhumans1859 ปีที่แล้ว +1

    i need this to turn a solonoid water valve on and off and have the water sensor on to but the vid dose not show that ?

    • @IACSElectronics
      @IACSElectronics  หลายเดือนก่อน

      Solenoid wiring is the same as pump wiring. We will be doing a video about solenoids in the near future. If you have any specific questions about your solenoid valve and project, please feel free to comment and we will make sure your questions are answered in more detail. 😊 Please note that solenoids can often cause a power surge, so you may need to fit a capacitor. Please let us know your solenoid details if you require further assistance.

  • @MackennaSilvas
    @MackennaSilvas ปีที่แล้ว +1

    Do you have updated links?

    • @IACSElectronics
      @IACSElectronics  ปีที่แล้ว

      Sorry for our slow reply, we have been working through backorders. The board shown in this video can be found at iacselectronics.com, updated links in description. Thanks!

  • @edwardagnel9873
    @edwardagnel9873 ปีที่แล้ว +1

    Hi how can I get these sensors?

    • @IACSElectronics
      @IACSElectronics  ปีที่แล้ว

      Hello, these are built to order. You can order them on our website iacselectronics.com

  • @Arnost_Kolomaznicek
    @Arnost_Kolomaznicek ปีที่แล้ว +1

    How do i connect this to the water pump? I mean, I want to install this inside of the water tank, and every time if the water will fall below the right water level, the sensor will turn on the water pump which is inside of the well

    • @IACSElectronics
      @IACSElectronics  หลายเดือนก่อน

      Yes this is achievable. Depending on the size of your pump and whether a single point of monitoring is sufficient, this kit is suitable. However you may want to consider our new fkx which offers many more protection features as well as a superior switching capacity and many other improvements. Please let us know if you have any further questions or more specific details about your installation.

  • @MegaKbyrne
    @MegaKbyrne 2 ปีที่แล้ว

    I need a video and board for two float switches. One low level turns on pump till it reaches second float switch that turns off pump. Pump in question will be a 12 vdc type. Any help would be appreciated.

    • @fancyfakename8967
      @fancyfakename8967 2 ปีที่แล้ว

      You could use a timer relay, set it to 10 minutes or whatever and use a second floatswitch(FS2) to disconnect power to that timer relay and reset the relay until FS1
      The lower switch (FS1) will activate the time relay and start the pump for X minutes.
      The higher switch (FS2) will return power to the relay as soon as the water level drops again, when it's low enough for FS1 then the relay starts the pump again.
      If FS2 fails for whatever reason then the pump will automatically stop after X minutes, minimizing overflow.
      It might be an idea to measure the time it needs to fill the reservoir and set time relay accordingly but differences in waterpressure might make this hard.
      Using a pressure vat results in consistent pressure for timer relay and less wear on the pump itself increases lifetime because it doesn't have to switch on/off each time the reservoir is filled.

    • @MegaKbyrne
      @MegaKbyrne 2 ปีที่แล้ว

      @@fancyfakename8967 Thank you for the info.

    • @IACSElectronics
      @IACSElectronics  ปีที่แล้ว

      @@MegaKbyrne We have released a version of this board which has 2 float switches and an intelligent control system to manage drainage or filling actions in various water tanks and scenarios.

  • @hendriklamar8381
    @hendriklamar8381 ปีที่แล้ว

    Can you not directly wire it on 12v?
    So the main live to one side of the switch, then on to the lamp on the other side, and the earth directly to the battery?

    • @IACSElectronics
      @IACSElectronics  11 หลายเดือนก่อน +1

      You can share the supply with the switching side provided it matches the supplies input voltage 12V DC.

    • @jonathanrodriguez8219
      @jonathanrodriguez8219 20 วันที่ผ่านมา +1

      @@IACSElectronics didn't we need to isolate the switch from the load? Is is safe to have the same supply?

    • @IACSElectronics
      @IACSElectronics  20 วันที่ผ่านมา

      @@jonathanrodriguez8219 hello thank you for your comment... If you are using something such as a solenoid running from a DC power source, you probably need to put some sort of circuit protection in to make sure that the fluctuation doesn't affect the board. We recommend the addition of a capacitor to the circuit if using a solenoid powered from the same DC circuit. The x series board has got built-in fluctuation protection but it is only limited. If you are using mains power or anything other than 12 volts DC for your switch side you definitely need to isolate it from the supply side of the board. Supply side range is 9 volts to 14.5 volts DC only. You can run a 12-volt DC pump from the same power source as the bored easily because the board is quite resilient and will protect its own circuitry. But you may need to account for drops in voltage if the pump takes a surge when it turns on.

  • @Stickky111
    @Stickky111 2 ปีที่แล้ว +1

    what are the little boards called?

    • @IACSElectronics
      @IACSElectronics  ปีที่แล้ว

      The blue circuit boards are 'float kit board' or FK0. We sometimes sell these individually.

  • @peshrawahmadebrahem991
    @peshrawahmadebrahem991 4 ปีที่แล้ว +1

    Can I run the board on a 100 amp and 12 volt battery?

    • @IACSElectronics
      @IACSElectronics  4 ปีที่แล้ว

      Hello, if that is a 100 amp as in amp hour (Ah) battery such as a lead acid leisure battery then the answer is yes you can, however if the battery puts out or spikes over 14.9 volts (e.g. if you have other things connected to the battery such as motors, compressors or chargers) it would be a good idea to connect a 12V regulator between the board and the battery, we can supply a suitable one (that can be adjusted / tuned to a good consistent voltage) with the board if needed for an additional 10 GBP.

    • @peshrawahmadebrahem991
      @peshrawahmadebrahem991 4 ปีที่แล้ว

      @@IACSElectronics Thanks for the reply Can I use Water Level Float Switch for the tank hho when empty without the board

    • @IACSElectronics
      @IACSElectronics  4 ปีที่แล้ว

      @@peshrawahmadebrahem991 You're welcome. The float switch its self can be used in an HHO tank provided the tempurature doesn't exceed 80 C / degrees centigrade. but it shouldn't be used to switch the load from a lead acid battery without the relay board because even under a low load, the power from a battery such as that will most likely weld the contacts inside the float switch / reed switch together causing it to stick in the ON position or burn out.

  • @Degirmen-eh3gn
    @Degirmen-eh3gn 10 หลายเดือนก่อน

    What I don't understand here is the sw connections that the water level sensor is connected to are negative or positive? If the sw connections are negative, can't both wires of the water level sensor be combined and plugged into one connection? Or if the sw connections are positive can't both wires of the water level sensor be combined and plugged into one connection? (I don't know if the sw connections are positive or negative, so I'm thinking of assumptions) If this assumption is correct, two separate water level sensors can be connected to two separate sw connections. Why are both wires of the water level sensor plugged into the sw connection separately? I will be glad if you answer this question. My aim is to use 3 water level sensors. What to do to connect multiple water level sensors?

    • @IACSElectronics
      @IACSElectronics  10 หลายเดือนก่อน

      Hello, they are in and out signal lines which puts out a positive voltage of approximately 3 to 5 volts. The second wire carries the signal back from the float switch. It is hypothetically possible to wire two switches either in series or parallel through that connector. However it would only work if you are going to be having the one relay switch operate when both are up or down. Some people use it as a backup incase a switch should ever fail.

    • @Degirmen-eh3gn
      @Degirmen-eh3gn 10 หลายเดือนก่อน

      @@IACSElectronics Light adapter everything is 12 volts... If we determined 3 levels and connected 3 sensors to measure the water level, what should the connections be? The way it works is as follows: The first light will turn on when the water rises to the 1st sensor level at the bottom, and the second light will turn on when the water level rises to the second sensor in the middle. The 3rd light will turn on when the water rises to the top sensor when the can is full.

  • @ramakrishnanswaminathan3654
    @ramakrishnanswaminathan3654 3 หลายเดือนก่อน +1

    Price and availability

    • @IACSElectronics
      @IACSElectronics  หลายเดือนก่อน

      Hello we are very sorry for the very late reply, we have been inundated with work and we have made many improvements to our services and products. At this precise moment, the best place to find our products is on Amazon. We will update the links in the description shortly. You can view data sheets on iacs electronics.com