ET-TV #13 - How to Avoid Pipework Vibration Problems (Top 6 Most Common Mistakes)

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 ต.ค. 2024

ความคิดเห็น • 8

  • @mustafaaljweijati7663
    @mustafaaljweijati7663 9 หลายเดือนก่อน +1

    Interesting conversation, I have question do you have simpler alternative for support? seems expensive support the one in the video.

  • @zejean
    @zejean ปีที่แล้ว +3

    Excellent presentation!

  • @119busanovic
    @119busanovic ปีที่แล้ว +2

    Great experience!!

  • @Running.guy7
    @Running.guy7 ปีที่แล้ว +2

    great! is there a minimum required length of SBC to supported? or just support a SBC regardless of the length?

    • @neilparkinson119
      @neilparkinson119 ปีที่แล้ว +3

      Thanks for your comment. The answer depends on the type of SBC. For simple cantilevered SBCs like the ones I showed in the presentation, the overall length should be minimised to reduce the risk. However for SBC which connect to a fixed point or which connect between 2 different main lines, the overall length must be ‘not less than a minimum allowable length’ as specified in the EI Guidelines. This length depends on the SBC branch diameter and the type of welded fitting e.g. Weldolet. Let me know if this answers your question. Regards, Neil

    • @squigglesbawd
      @squigglesbawd ปีที่แล้ว +2

      @@neilparkinson119 thanks for the reply.