NEVER Use This High Current DC Circuit Breaker For Solar, Auto, or Marine!

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ม.ค. 2021
  • See a high current DC Circuit breaker for solar, auto, or marine use that you should never use. Something you should definitely avoid. A quick follow up on my 12V LiFePO4 battery & BMS, then I perform a few tests on the high current DC circuit breaker that many people use for solar & auto applications, followed by a complete teardown. Enjoy the video!
    Great Deal on (4) quality 135Ah LiFePO4 Cells w/Free Shipping: s.click.aliexpress.com/e/_9G3lYt
    100A BMS used in video: s.click.aliexpress.com/e/_d7c...
    200A & Other Breakers: amzn.to/3njEjK6
    ANL Fuses & Holders: amzn.to/38tLaw7
    MEGA Fuses & Holders: amzn.to/3q54gid
    Thermal Imaging Camera: bit.ly/3feqjgr
    Tacklife Clamp CM06 Tester: amzn.to/38L0OlW
    Powerwalls & MUCH More: bigbattery.com/ref/19
    *10% Off Discount at BigBattery: electronicsNmore10*
    *Amazon, BigBattery, Aliexpress, & Banggood Affiliate Links Above (I earn a small commission from qualifying purchases)
    Support the creation of new videos on my channel by watching ads placed on my videos, shopping for items shown in my videos(No additional cost to you) at the links provided above, and continuing to use the supplied online store links for future purchases. You can also support my work by making a Paypal donation. All donations, big or small, are greatly appreciated since many of the videos I produce don't go viral and make all the hours of work I put into them worthwhile. Thank you!
    Paypal link: paypal.me/electronicsNmoreYT
    Bobby Tectalabyss: Thanks for your generous $5 donation!
    Jeff Barr: Thanks for your generous $25 donation!
    xrayjim: Thanks for your generous $25 donation!
    Ryan Pedersen: Thanks for your generous $20 donation!
    Wanda Thomas: Thanks for your generous $50 donation!
    Peter Hines: Thanks for your generous $10 donation!
    Verinspec: Thanks for your generous $10 donation!
    Jason Enright: Thanks for your generous $6 donation!
    Diega Kendrick: Thanks for your generous $10 donation!
    Technovative Products: Thanks for your generous $5 donation!
    Jeff Karrow: Thanks for your generous $5 donation!
    Iven Brown: Thanks for your generous $5 donation!
    Thomas Herrick: Thanks for your generous $20 donation!
    Richard Frisch: Thanks for your generous $10 donation!
    Bruce Howard: Thanks for the generous $5 donation!
    Jayantha Gabbalage: Thanks for the generous $20 donation!
    Joseph Vanderbosch: Thanks for the generous $10 donation!
    Theodosia Gougousi: Thanks for the generous $10 donation!
    Ric Dezorzi: Thanks for the generous $5 donation!
    Randy Schader: Thanks for the generous $5 donation!
    Hong Lin: Thanks for your generous $20 donation!
    Thanks For Watching!
    **If you enjoy watching my videos, then be sure to SUBSCRIBE & click the notification bell(set to "ALL"), SHARE links to my videos with others, rate "THUMBS UP", and check out my extensive video playlists for many other videos of interest to you. Doing so helps to ensure that many more videos will be uploaded to my YT channel in the future.**
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 415

  • @ProjectFarm
    @ProjectFarm 3 ปีที่แล้ว +100

    Thanks for saving me from disappointment! Looking forward to your next video!

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +11

      You're welcome! Many more videos to follow. Looking forward to your next great testing video. Thanks for watching!

    • @kevinmills5293
      @kevinmills5293 2 ปีที่แล้ว +2

      Too late for me I’m afraid.

    • @unknown-ql1fk
      @unknown-ql1fk 2 ปีที่แล้ว

      I had a breaker like this in my boat. The thing LITERALLY lit on fire-in my bilge...near my gas tank...im lucky to be alive. Glad I clean the bingle so no oil/gas vapors, I had to cut the wires off and twist them together with the addition of 10ft of steel leader wire to handle the current

    • @jec_ecart
      @jec_ecart 2 ปีที่แล้ว +3

      Wow. It's project farm.

    • @realisticclearmind3531
      @realisticclearmind3531 2 ปีที่แล้ว +1

      Test by yourself.

  • @VanwithTim
    @VanwithTim 3 ปีที่แล้ว +8

    Fantastic in depth tear down.
    I remember thinking my power inverter was faulty, and couldn't understand why my grossly oversized cables were heating up. Ended up being this cheap style breaker giving me headaches.
    I rarely subscribe, but I'm happy to have your channel as my third subscription.
    Top quality information.

  • @kerry4951
    @kerry4951 ปีที่แล้ว +1

    Im so glad you posted this video. I have been using the same 300 amp circuit breaker in my RV and its been popping off prematurely. Thanks for the in sight.

  • @potteryjoe
    @potteryjoe 3 ปีที่แล้ว +10

    Always good to see a real breakdown of cheap components. Thanks!

  • @walterlangkowski4723
    @walterlangkowski4723 ปีที่แล้ว +3

    Underrated video for sure
    I would love to see your recommendation on an actually good breaker to use

  • @JT-lq4yd
    @JT-lq4yd 3 ปีที่แล้ว +17

    Doug, thanks for the PSA. I have been looking at a DC circuit breaker for a long time, but didn't want to pay a lot of money or having to deal with having extra fuses. That answers the question, an expensive breaker is cheaper than a good inverter, or fire damage.
    I like these types of valuable videos.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      You're welcome! Thanks for watching

    • @camposvazquez
      @camposvazquez ปีที่แล้ว +1

      @@electronicsNmore eNm... Have you tested the Bussmann DC circuit breakers... I see them used off grid and in the marine industry...

  • @DF-te2vm
    @DF-te2vm 2 ปีที่แล้ว +12

    Measure the voltage across the breaker at different amps, all thermal breakers have differing trip times because they all have to heat up to trip. More important breakers use curves graphs to show how long to trip at differing amps.

  • @experiment86
    @experiment86 2 ปีที่แล้ว +2

    Thanks for the teardown and analysis of this type of breaker. I have always heard bad things about them because of nuisance tripping. Good to understand why. I like the battery pack too.

  • @aznative_
    @aznative_ 3 ปีที่แล้ว +1

    I bought a couple of those years ago and never used them because I wanted to test them first. I never got around to it. Thanks for saving me the headache of either testing them myself or more likely swapping out components that didn't work properly.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      No problem Brandon! Be sure to rate thumbs up, subscribe, and take one minute to share a link to my channel with others on social networking sites. Thank you!
      th-cam.com/users/electronicsnmoreplaylists

    • @aznative_
      @aznative_ 3 ปีที่แล้ว

      @@electronicsNmore Absolutely! I rang that Bell long ago LOL you're definitely on my top 5 TH-cam channels. In no particular order they would be AVE, Big Clive, Project Farm, ElectronicsNmore and solar by Will Prowse.

  • @lloydprunier4415
    @lloydprunier4415 2 ปีที่แล้ว +1

    Glad you made this video, I have 2 of these breakers one on my truck amplifiers and one on my boat for the 24vdc trolling motor. I will look for the BUSS breakers right away! Thanks again!

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว +1

      Glad I could help! Be sure to rate thumbs up and look over my extensive video playlists below for many other videos of interest to you. Taking one minute to share a link to my channel with others on social networking sites would be greatly appreciated. Thank you
      th-cam.com/users/electronicsnmoreplaylists

  • @SheriffJackCarter
    @SheriffJackCarter 2 ปีที่แล้ว +2

    I use a T Tocas Superior E9-90 that costs $26. This one has multiple S.A.E and UL certifications. It's also listed as waterproof and ignition protected. It doesn't have the subsurface lug issue and I have had no noticeable issues with it's operation nor any over-current trips even with my system cranked in freezing or hot weather. For reference, my sound system is a pair of Rockford Fosgate P3D2-12 sub-woofers powered by a Rockford Fosgate R1200-1D Prime amplifier and a RFC2D digital capacitor.

  • @EngineerMikeF
    @EngineerMikeF 3 ปีที่แล้ว +14

    Chinesium. Problem IMO is the small silver coated contact. U can see the arcing marks in the silver, there is arcing happening at the contact 'patch' so it isn't making contact over enough surface area, the arcing causes resistance & heat , heat opens the connection. Contacts have to be adequate size & also machined accurately so there will be enough contact area to pass full volts & amps.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      I would also say that's the most likely problem. Thanks for watching!

  • @ThriftyToolShed
    @ThriftyToolShed 2 ปีที่แล้ว +1

    Thanks. I had one of these in my cart to buy. I will use fuses instead for my project. Excellent video!

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว +1

      You're welcome! Be sure to check out my very wide range of videos and share. Thanks

  • @danielt4730
    @danielt4730 2 ปีที่แล้ว +2

    Great video. I've always wanted to see inside one. I dont use these red and black ones anymore, I use the yellow and black one.

  • @christopherbeneke2242
    @christopherbeneke2242 2 ปีที่แล้ว +2

    I think you might have just helped me diagnose an issue in my 12v system. I have a similar 200 amp breaker between my battery and the rest of the the electrical. After about 5-10 minutes under highish load (around 100 amps), my inverter, solar charge controller, and other devices powered through the breaker all shut off and immediately restart. Nothing shows up in the BMS app to indicate I've exceeded its 130 amp max output setting. I assumed it was either a problem with my BMS or with my inverter because the breaker never actually tripped. Based on your video, I'm thinking that maybe the breaker is heating up causing a temporary disconnect without actually causing the breaker to trip. I never thought it might be the $25 breaker I bought on Amazon. I didn't know much about breakers so I didn't realize that a $25 dollar breaker was "cheap". I've ordered a Blue Sea breaker and after I install it I hope my random micro-outages will be in the past!

  • @anthonyvolkman2338
    @anthonyvolkman2338 3 ปีที่แล้ว +3

    Thank you for the warning! I almost purchased some of those breakers! Now going with Bussmann! Thank you.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      You're welcome Anthony! Be sure to rate thumbs up, subscribe, and look over my extensive video playlists below for many other videos of interest to you. Taking one minute to share a link to my channel with others on social networking sites would be greatly appreciated. Thanks
      th-cam.com/users/electronicsnmoreplaylists

    • @anthonyvolkman2338
      @anthonyvolkman2338 3 ปีที่แล้ว

      @@electronicsNmore Will do!

  • @mr.skipper4544
    @mr.skipper4544 2 ปีที่แล้ว +1

    I will be getting rid of all mine in my van thanks for sharing this

  • @DIYwithBatteries
    @DIYwithBatteries 3 ปีที่แล้ว +5

    It's going to be bigger and bigger keep up the awesome content Sir like it. 👍

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Thanks for watching! Glad you liked the video! Be sure to share.

  • @polishhotdog933
    @polishhotdog933 3 ปีที่แล้ว +2

    Well done! Very thorough as usual.

  • @joshnabours9102
    @joshnabours9102 2 ปีที่แล้ว +1

    I would recommend using a commercial 200 A breaker for a high amp potentially fire causing use case like these batteries. Or a 200 amp fuse at bare minimum. You will want to watch eev blog's video on glass fuses before going the fuse route though. Some fuses can vary greatly in how fast or slow they blow in certain conditions.

  • @jackoneil3933
    @jackoneil3933 2 ปีที่แล้ว +1

    Indeed, Looks like junk from the top down. Something worth considering is that generally fuses are intended for overload protection and fuses for short circuit protection.

  • @sapelesteve
    @sapelesteve 3 ปีที่แล้ว +2

    Excellent video Doug! Watching the video I was wondering what the difference is between that circuit breaker & the breakers found on electrical home panels? Thanks for these videos.... 👍👍

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      Glad you enjoyed the video Steve! They work very similar, a bimetallic strip, with springs. Some AC breakers are rated for DC. Thanks for watching!

    • @billharris6886
      @billharris6886 2 ปีที่แล้ว +2

      Breakers in the house are a magnetic and thermal type, rated for AC only. You can't use an AC breaker on DC because, DC requires about 4 times the open gap to prevent arcing. There are some combination magnetic/thermal breakers made for DC but, they can only be used in a circuit where the current flow can only occur in one direction only because, these breakers have a polarity associated with them. If hooked up backwards, they don't trip, they just catch on fire. You would never want to use this type breaker between a solar charge controller and a battery bus for instance.

  • @Quickened1
    @Quickened1 3 ปีที่แล้ว +2

    I noticed something that could explain part of the problem. I don't know if it was like that prior to disassembly, or was a result of the disassembly process, but right in the center of the bi-metal plate, there is an obvious dent. That dent would definitely affect accuracy. If it occurred during the process of taking it apart, then please disregard... Either way, that breaker fittingly, received a hammer... Great, informative video as usual!

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +2

      I did that. Lol.

    • @Quickened1
      @Quickened1 3 ปีที่แล้ว +2

      @@electronicsNmore oh..ok... Might actually work better now! Haha...

  • @MicBergsma
    @MicBergsma 2 ปีที่แล้ว +1

    Interesting, thanks for sharing, I am gonna stick with mega fuse, mahalo!

  • @victorrizal5535
    @victorrizal5535 ปีที่แล้ว +1

    Great, thanks for your solid information sir

  • @joatmofa0405
    @joatmofa0405 3 ปีที่แล้ว +3

    Very interesting...thanks for the "post-mortem" operation!

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Glad you enjoyed it! Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others on social networking sites. Thanks
      th-cam.com/users/electronicsnmoreplaylists

  • @James-fe7wd
    @James-fe7wd 2 ปีที่แล้ว +1

    Thanks for this highly informative and beautifully concise video, definitely subbing to you sir!

  • @NewLightEnergy
    @NewLightEnergy 4 หลายเดือนก่อน

    Fantastic video, ty for doing this test, those things have death written all over them. Will buy full sized Schneider or victron breakers.

  • @ffindog
    @ffindog 2 ปีที่แล้ว +2

    This style of breaker works fine as long as you don’t buy cheap crap one!!
    I was having drama’s with 60 amp no name unit tripping with only a 30 amp load. Went to a 100amp cheap unit same problem started tripping due to screw terminals getting hot.
    Swapped it out for a 40 amp blueseas breaker and it has not false tripped once or got warm at all. The old saying apply’s here. “You get what you pay for”

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      I never said the style was bad, I said if it looks just like what you see in this video, don't buy it. Bussman and Blue Sea are OK.

  • @slicktop2jz855
    @slicktop2jz855 3 ปีที่แล้ว +1

    Thanks buddy. Almost just purchased a 150amp breaker for my car.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      Use one of the fuses instead, much cheaper. Have a spare on hand, and make sure it's properly sized. Thanks for watching! Be sure to rate thumbs up and share the video link with others.

  • @ubergeek318
    @ubergeek318 2 ปีที่แล้ว +1

    If you want to try a better breaker, look at the Rockford Fosgate brand. I have ran a 12k winch for a good pull and it worked a premium. The style you have shown also don't make a good contact on the input and output

  • @beyondfossil
    @beyondfossil 2 ปีที่แล้ว

    I also had a problem with these 200A resettable fuses. It did trip from high current correctly. So I reset the fuse. But the battery connection became very "flaky" like working for a few minutes, then just stopping for no apparent reason because the fuse was *not* tripped. Yet I couldn't get power in or out of the battery. Could't figure it out for a while and frustratingly had to start taking apart my system to try to find the problem. The problem was the fuse itself! I tested its resistance from pole to pole and it had a huge 1MΩ resistance! I bypassed the DC fuse and confirmed the problem was definitely the DC fuse.
    For a while, I considered my BMS was messed up. The BMS has its own MOSFET type software driven fuse. But it was *not* the BMS.
    Also, I had one 100A fuse (of the same style) for a different part of the system. It kept on tripping prematurely at 31A to 33A. Lucky I was able to return that one to Amazon for full refund because my charger regularly hits those current levels as part of its regular specified operation.
    Now I just use a regular non-resettable ANL fuse with some spare fuses around. But I like the resettable feature because you can also use these fuses as switches to disable/enable parts of your circuit for maintenance/upgrades etc. Still looking.

  • @davewright3088
    @davewright3088 2 ปีที่แล้ว +1

    Nice presentation..! In future, would be good to measure voltage drop of switches, breakers and fuses at load currents. Milli-ohms matter at >100A...

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Glad you liked it! I'll keep what you said in mind for future videos.

  • @rocktech7144
    @rocktech7144 3 ปีที่แล้ว +3

    Nice vid. Well illustrated. I use square D ac breakers. QM breakers are rated at 60vdc and QO breakers are rated at 48vdc. NOT the ones you find at home despot. You can find these at electrical supply outlets.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Thank you! Yes, they can be used, but I think they only go up to 60 or 70A.

    • @rocktech7144
      @rocktech7144 3 ปีที่แล้ว +1

      @@electronicsNmore QM go to 200 amps. I have a 2 pole 100 amp protecting my battery bank. Says rated for 60vdc right on the breaker. Surplus cost $25.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      @@rocktech7144 You stole that, they're expensive.

    • @marclefaucheur9178
      @marclefaucheur9178 ปีที่แล้ว

      @@rocktech7144 Hi RockTech, where is your source for sq d QM 60v breakers. Thanks

  • @CodeCharmer
    @CodeCharmer 2 ปีที่แล้ว

    I think you hit the nail on the head at 13:15. That BS dimple on the plate can't be making a great contact to the silver contact on the brass buss.

  • @jmpcrx
    @jmpcrx ปีที่แล้ว

    Thanks... Do you know of a good make at a reasonable price? As im doing my own diy solar setup and need a 200amp dc breaker! Was looking at these, but not now 😱. 👍

  • @haroldhprittjr7007
    @haroldhprittjr7007 2 ปีที่แล้ว +1

    Thanks for informing video I have 4 different types of these the two I’m gonna use are Allen set screw I do have the same type as you show. I got the Allen type and I got about two hundred more amps then I needed at the battery but I got fuses at my amps if they don’t work I’ll have to change out to better or fuses up thanks again!

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Glad to help Harold! Be sure to check out my very wide range of videos and share. Thanks

  • @beyondfossil
    @beyondfossil 2 ปีที่แล้ว

    Dunno about those more expensive name brand DC resettable fuses. You go on Amazon and people complain about the same type of problems happening on those expensive resettable fuses also. Apparently, DC fuses are much more tricky to implement than AC fuses due to some physics I don't yet fathom.
    But a big contributor to this the sparking *oxidation* from rapid connect/disconnect under load. The switch *always* sparks if there is load at the time of connect/disconnect. The spark oxidizes the metal at contact point which deteriorates the conductor. Not sure how household AC fuses deal with it as the same thing happens inside them as well. So each time you switch the fuse under load, you damage the conductive part a little bit.
    The only way to deal with sparking problem long-term is to use a resistor or "sacrificial" part of the conductor that is active only during the very small period of time at the moment of first contact or disconnect. So, during connection, the resistor/sacrifice makes first contact. Conversely, during disconnect, the resistor/sacrifice is last to lose contact. So if the "expensive" fuse doesn't have this feature, the same type of heating problems will eventually plague them as well.

  • @ThePreyMantas
    @ThePreyMantas 3 ปีที่แล้ว +2

    Sorry you had to deal with another barely/poorly, designed/engineered, piece of crap, but we appreciate you sharing your experiences. It's good folks like you sharing these things honestly that makes YT worth our time, thanks!

  • @sylvestersmith7651
    @sylvestersmith7651 3 ปีที่แล้ว +1

    Good tear-down

  • @mygadgetzhaiqal7410
    @mygadgetzhaiqal7410 8 หลายเดือนก่อน

    Just curious, the breaker should connect to positive or negative battery?

  • @johnnyherring4825
    @johnnyherring4825 2 ปีที่แล้ว

    I have a sxs and 1 night we rode went to sleep and woke up to my sxs almost on fire something shorted out so now I take battery cable off everytime it's going to be setting without me right there by it anyway I want to put a breaker on it NOT FOR PROTECTION but just to kill all power so I don't have to keep putting cables on and off a ac breaker would fit best in space I have what do yall recommend I use thanks in advance....

  • @billspradlin9619
    @billspradlin9619 2 ปีที่แล้ว +1

    Thanks for the investigation

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      You're welcome Bill! Be sure to rate thumbs up, consider subscribing if you like a wide range of helpful and informative videos, and look over my extensive video playlists below for many other videos of interest to you. Taking one minute to share a link to my channel with others on social networking sites would be greatly appreciated. Thank you
      th-cam.com/users/electronicsnmoreplaylists

  • @Oorfmeister
    @Oorfmeister 6 หลายเดือนก่อน

    Hey can you do a similar breakdown on a couple other brands like T Tocas ?

  • @JamesWilliams-vi8zr
    @JamesWilliams-vi8zr 3 ปีที่แล้ว +7

    A 200 amp (standard-rated) breaker should trip at a 200 amp spike. Constant load rating is 80% or 160 amps. That breaker should have been able to handle 154 amps without overheating and tripping. Just like their battery ratings, you never know what your going to get. Thanks for the informative videos!

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Thanks for watching James! Be sure to look over my video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others on social networking sites.
      th-cam.com/users/electronicsnmoreplaylists

    • @schappeau
      @schappeau 2 ปีที่แล้ว +4

      This is an interesting fact, since this is different to Europe: In Europe the rated current of a breaker is the maximum continuous current. Depending on the characteristic of the breaker (there are several different available) the breaker should trip at a current of 1.05 to 1.5 times of the rated current, if they have an additional magnetic based short circuit detection this should trigger at 1.5 (circuit breakers in Europe usually have a thermal based over current protection plus a magnetic based short curcuit protection)

  • @kingjames8283
    @kingjames8283 2 ปีที่แล้ว

    Shucks, wish I had known sooner. Bought two 200-amp and four 50-amp. Still in box, haven't used them yet. Intent was for battery groups to the DC/AC inverters. Have since purchased large blade type 200-amp fuses.

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Live and learn. Fuses are cheaper and reliable. Thanks for watching!

  • @mightystreaming933
    @mightystreaming933 3 ปีที่แล้ว +2

    i used Eaton Cooper Bussmann 187 Series Reset Circuit Breakers 30 and 75 amp. $49.50 each but well worth it. i also use max wiring size on my solar project. for 200 amp id use midnite solar.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Eaton makes good breakers. Midnite solar makes good stuff. Thanks for watching!

    • @mightystreaming933
      @mightystreaming933 3 ปีที่แล้ว

      @@electronicsNmore i found you researching SWIPOWER/CNSWIPOWER 3000W/6000W off-grid pure sine wave inverter. very well done and you have earned a subscribe from me.

  • @dastanharris
    @dastanharris ปีที่แล้ว +1

    good enough for me for small apliances as long as it triggers lower than what its rated for

  • @danielnagy5721
    @danielnagy5721 2 ปีที่แล้ว

    At least on Banggood, the description is talking about car audio system, so it seems the intended use is for powerful car amps. I think for that purpose it might be perfect, regarding it's price.

  • @dennissecor8092
    @dennissecor8092 2 ปีที่แล้ว

    I have an anl, 100 amp fuse holder, and over a short amount of time, a couple months, it provides power, for a 1000, watt, inverter, and the fuse holder melts, o already replaced it a couple months ago, and its doing the same thing again, not sure why, and I use it to power a coffee pot, 5 cup, and to power a battery charger, to charge a marine, deep cycle agm battery, I'm assuming, I'm going to have to increase, the wire size, from 4awg, to 0 awg?

  • @Aerogrow
    @Aerogrow 2 ปีที่แล้ว

    bah... so you are saying I am spending 200-300 on that victron lynx Distributor.
    Nice vid; was having same concerns when I saw how flimsy the 300A version was.

  • @albertvanlingen7590
    @albertvanlingen7590 3 ปีที่แล้ว

    Love your very helpful videos. I have an old damaged "Tevo Magneto Rechargeable LED Lantern" that I want to salvage the LED light panel from and run it directly of mains if possible. Could you please please please make a video of that. I don't want to through away the unit if there are still working LED lights on it.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      How much power does it draw and what voltage?

    • @albertvanlingen7590
      @albertvanlingen7590 3 ปีที่แล้ว

      @@electronicsNmore thanks for your reply. It says charging voltage: 220-240V , 50/60Hz and it had a 6V 4AH battery. I'm in Africa 😊

  • @DanBurgaud
    @DanBurgaud 2 ปีที่แล้ว

    5:16 As seen on your thermal cam, it was the part of the wire under the black heat shrink tubing that was heating up the most.
    6:23 "..this brass section..."
    OK... if that is brass, then it is definitely NOT FIT for high current. It should be pure copper.
    8:00 this 2nd test is convincing.

  • @dwmcever
    @dwmcever 2 ปีที่แล้ว +5

    These type of breaker switches do not have a magnet to draw off the DC arc. They are good for 2-5 load breaks and that's it. Don't use it as a switch under load. Just like you shouldn't use a AC circuit breaker as a switch.

    • @josephwalters1563
      @josephwalters1563 2 ปีที่แล้ว +3

      This is not necessarily true. 1kA sure, some magnets to extend the arc, oil to quench the arc, etc all help. At 200a though the silver contacts when properly sized, with enough plating and strong enough return springs to promote fast opening time are sufficient, break open some name brand starter contactors from little fuse, trombetta, etc will reveal this is sufficient for 50,000-100,000 make/brake cycles

  • @huysworld701
    @huysworld701 3 ปีที่แล้ว +1

    Regardless of the bad breaker .. your battery set up is very nice 👍

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Thanks for watching! Be sure to look over my extensive video playlists below for many other videos of interest to you.
      th-cam.com/users/electronicsnmoreplaylists

  • @bryanst.martin7134
    @bryanst.martin7134 2 ปีที่แล้ว

    Each time a DC breaker is tripped under load an arc etches the contact faces. Each additional use will cause heat rises due to poor contact. Start with quality and use with respect. Frequently measuring the voltage drop across the terminals will give a great heads up to pending failures.

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Yes, the breaker should never be used as a switch when the load is connected.

  • @tkittich
    @tkittich 3 ปีที่แล้ว +1

    Thanks for the video. Do you have a recommended 250A breakers for solar use?

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      Hi there. I prefer Bussman / Blue Sea, but others of similar design will work. Definitely avoid the type seen in this video. Thanks for watching!
      amzn.to/3qOSJ7x
      (Amazon Affiliate Link)

  • @pavelkracmar4062
    @pavelkracmar4062 3 ปีที่แล้ว +4

    If the BMS has an external thermal sensor, simply connect a small OFF switch in parallel.

    • @sambadii
      @sambadii ปีที่แล้ว

      Good idea! Thank you!

  • @chanakasuresh89
    @chanakasuresh89 2 ปีที่แล้ว +1

    Thanks for this!!!!

  • @charliefrancis6438
    @charliefrancis6438 ปีที่แล้ว

    Had the same problems with my 400 amp circuit breakers they opened up at at least half their rated power , switched to fuses and no false trips , I really wanted circuit breakers cause of their disconnect ability so much easier than un bolting a fuse any know a reliable good 12 v circuit breaker brand?

  • @woodrunner51
    @woodrunner51 3 ปีที่แล้ว +1

    tnx...i ordered it 1 week ago xD
    I wish i saw this sooner lol

  • @mikenewman4078
    @mikenewman4078 3 ปีที่แล้ว

    Thanks. I have some of these at about 50 Amps, time to remove them. Normal Clipsal 250 VAC breakers are rated to 48 VDC so i will use them in a single pole enclosure for 12 VDC.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      You're welcome Mike! Smart move. Be sure to rate thumbs up, subscribe, and look over my extensive video playlists below for many other videos of interest to you. Taking one minute to share a link to my channel with others on social networking sites would be greatly appreciated. Thank you
      th-cam.com/users/electronicsnmoreplaylists

  • @jws3925
    @jws3925 2 ปีที่แล้ว

    Recommendations for breakers? Updating current system.

  • @DP-pe2xe
    @DP-pe2xe 2 ปีที่แล้ว +8

    I agree that breaker is crap, but 200A should be it's breaking capability, not triggering current. According to your tests I would say that this is ''200A'' breaker with 63A triggering current, medium or slow type.
    I like your videos very much.
    Keep going like this :)

    • @SnowGolem1TheL33t
      @SnowGolem1TheL33t 2 ปีที่แล้ว +1

      No 200A should definitely be the triggering current. That would be like rating a 50A fuse 200A, it would blow as soon as you turn on the load.
      That is NOT how we rate electrical protection devices.

    • @DP-pe2xe
      @DP-pe2xe 2 ปีที่แล้ว

      @@SnowGolem1TheL33t There is a difference between CIRCUIT BREAKER and automatic FUSE. Fuse should trigger at rated current, and circuit breaker should be able to brake electric circuit at rated current, circuit breaker, if it has triggering function, could be sett to trigger at less value than it's maximum rated current, according to circuit designed current.
      This is of course nonsense, because there is no way to sett triggering current, thus to achieve it's braking capacity current :)

  • @cluso9985
    @cluso9985 หลายเดือนก่อน +1

    Steer clear of any protective gear (circuit breakers, fuses, switches, etc) that doesn’t have a manufacturer’s brand/logo on it. Also beware of fakes that have a false brand/logo on them. If it’s half price or less than the rrp, it’s likely a fake or inferior.
    Unfortunately reliable brands have enormous markups for the distributors and retailers, making these fakes and inferiors so attractive!

  • @macslife
    @macslife 2 ปีที่แล้ว +1

    Great video mate. Just got a sub!

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Awesome, thank you! Be sure to rate thumbs up and look over my extensive video playlists below for many other videos of interest to you. Taking one minute to share a link to my channel with others on social networking sites would be greatly appreciated.
      th-cam.com/users/electronicsnmoreplaylists

  • @cruzincondo3395
    @cruzincondo3395 2 ปีที่แล้ว +1

    Nailed it.

  • @allynonderdonk7577
    @allynonderdonk7577 ปีที่แล้ว

    I've had several of those breakers. Typically they have the same housing with the current rating as in the video. Those are defective. I have ordered several that say waterproof and ignition protected on the front and those work just fine. Those breakers are physically a different size slightly.

  • @aspendell209
    @aspendell209 3 ปีที่แล้ว +3

    It appears you purchased a couple of the cheap chinesium knock-offs. Once you find a good supplier on eBay, these type of breakers work just fine. I have a few 150-250 amp breakers of this style that all trip within 10% of rated current. And $15 to $20 is a whole lot cheaper than $100 - $200 for a Blue Sea equivalent. The key is to look for breakers that have brand and UL listing info on them. Its also a lot safer to throw a $15 breaker into a new system, than to hold off until you can afford $100+ for a new breaker.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      They are made in China, there's nothing to KO. The style shown in this video, same housing, same lever, same reset button,etc.....a definite avoid.

  • @DanBurgaud
    @DanBurgaud 2 ปีที่แล้ว

    2:56 "...when you do this..." weren't you hindering the little red button from moving thus preventing it from latching?
    3:50 yet when you did not touch it, it still did not latch... so it is bad

  • @jameshoff9435
    @jameshoff9435 ปีที่แล้ว

    13;25, The pressure on the contact may be substandard. As the concave plate started to heat up at 150a the pressure on the contact weakens even more, in-turn, increasing resistance / heat production, popping the device prematurely. As pointed out, poor quality device in several areas.

  • @scottdowney4318
    @scottdowney4318 2 ปีที่แล้ว

    one bad thing if using brass, it does not have very good conductivity as pure copper. Electrical Conductivity of Materials - Blue Sea Systems
    The differences in electrical conductivity of various materials used in marine electrical products are often not well understood. Making assumptions about the electrical conductivity of a material because it looks similar to another conductive material of known ampacity can lead to disastrous results.
    Perhaps the most common form of this error is the substitution of brass or bronze for copper in electrical applications. Brass is only 28% as conductive as copper. Some bronzes are as low as 7% as conductive as copper!
    Copper is the standard by which electrical materials are rated and conductivity ratings are expressed as a relative measurement to copper. These ratings will frequently be expressed as "28 IACS". IACS is the abbreviation for International Annealed Copper Standard and the number preceding "IACS" is the percentage of conductivity a material has relative to copper, which is considered to be 100% conductive. This does not mean that copper has no resistance (is 100% conductive in an absolute sense), but rather that it is the standard by which other materials are measured. The higher the % IACS, the more conductive the material is. This standard refers to a pure, "standard" copper having a resistivity of 1.7241 microhm-cm at 20°C (68°F).
    Armed with this knowledge it is interesting to examine the IACS conductivity values of some common materials.

  • @walleyeye
    @walleyeye ปีที่แล้ว

    Really good video.

  • @jean-yvesdore4312
    @jean-yvesdore4312 ปีที่แล้ว +1

    very well done video.

    • @electronicsNmore
      @electronicsNmore  ปีที่แล้ว

      Thank you! Glad you enjoyed it Jean. Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others.
      th-cam.com/users/electronicsnmoreplaylists

  • @digitalwallis9608
    @digitalwallis9608 2 ปีที่แล้ว +1

    Thanks, But it was to late for me, had it to learn the Hard way. Mine 200A Part could not hold 120A for 2 h now i use Mega Fuses.

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว +1

      MEGA fuses are a good way to go, and fairly inexpensive.

  • @wim0104
    @wim0104 3 ปีที่แล้ว +1

    Don't forget Square-D's QO breakers are rated/listed for DC, up to 96V, AFAIR. Put them in one of those cheap little spa panels.

    • @wim0104
      @wim0104 3 ปีที่แล้ว

      One look at these things and you can see they can't safely manage 200Amps, Go look at your main breaker in your service panel: and remember, that one is for AC. DC current is even harder to break up.

    • @wim0104
      @wim0104 3 ปีที่แล้ว

      and even with the BUSS 200A breaker: how the hell are you gonna attach something like an AWG2 cable to those little posts??
      Don't forget, we're also supposed to de-rate for DC (now you're looking at AWG1 or 0...)
      To safely control 200A, you should use a distribution panel, and the Square-D QO breakers.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว +1

      True! I've seen them. SQ-D is good.

  • @giuseppedesposito5418
    @giuseppedesposito5418 ปีที่แล้ว

    What's the voltage you're using? What's the rated voltage of the cheap breaker?

  • @xtremeownagedotcom
    @xtremeownagedotcom 2 ปีที่แล้ว

    I had one of those on my truck..... Not even a ton of current going through it- just internal/external electrics and it took a dump.

  • @davyp2993
    @davyp2993 2 ปีที่แล้ว +6

    Thanks, as a retired electrician I was hoping to use c/b's instead of fuses in my DIY, Lifepo4 system on my boat.
    I suppose it was laziness being able to throw a c/b instead of replacing a fuse, but I think I will go "old school".
    Fuses are fiddly, but reliable.

    • @bdykes7316
      @bdykes7316 2 ปีที่แล้ว +2

      Midnite Solar sells proper bidirectional DC circuit breakers. I think some models are UL rated up to 120vDC.

  • @tiffanywelton5116
    @tiffanywelton5116 3 ปีที่แล้ว

    Are Attwood marine, manual circuit breakers good for like 12v 6-100Ah deep cycle batteries for outboard trolling motors?

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      I never tested them, the Bussman and Blue Sea I know are just fine. Thanks for watching!

  • @jcpt928
    @jcpt928 2 ปีที่แล้ว

    I had a pair of these on a solar battery bank for the incoming current - they didn't last more than a few days before I sent them back due to concern about safety and operation.

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว +1

      They have no business selling these, they're almost worthless. Thanks for watching

  • @jwag2708
    @jwag2708 6 หลายเดือนก่อน +1

    I'd recommend against that Mini ANL fuse holder... very cheap and the plastic will just melt under load, leaving exposed metal that still hasn't broken apart... very dangerous.

  • @cotandiet6096
    @cotandiet6096 10 หลายเดือนก่อน +2

    Replace the brass washer with a copper one.

  • @realisticclearmind3531
    @realisticclearmind3531 2 ปีที่แล้ว

    I use some of them with different amps.
    In another video i saw a test about breakers. It was about the 100 Amp one. And this one works the best.
    100 Amp shut down at 99.7 Amp. Ok could a bit higher but others shut down at 150 or even 230 Amps.
    There are a view of them on the Market and I'm not sure they all bad.

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      I don't trust any of these. I'll stick with Blue Sea and others.

  • @radstorm
    @radstorm 3 หลายเดือนก่อน

    I'm new to solar stuff. But a hair dryer pulls 68 amps? Sorry I don't understand why when it only pulls 1500 watts roughly.

  • @gconol
    @gconol 2 ปีที่แล้ว

    I have always wondered how that thing could handle 200A. The post are TINY !!!!! I have a few of them in the box unopened.

  • @allennolden8735
    @allennolden8735 2 ปีที่แล้ว +2

    Seems like you just have a cheap model of that breaker. I've used those quite often in many of my builds and they hold up just fine. Many of the other ANL fuses I've used melted under the same conditions. If I use ANL I typically had to buy the ceramic models.

  • @kentonevans
    @kentonevans 3 ปีที่แล้ว

    It seems clear that the contact area (referred to as the 'silver' part) is the problem. It's even discoloured where it's been arcing. This is a design flaw. While it's true that the parts have to be quite rigid (unsprung) to ensure disconnection in these cheap parts, it looks like the geometry is poor. Also, it's hard to believe that thermal response tolerances (of the enclosure and the plate) have be ensured in such a woeful device, even if the contact were perfect.

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      As I learned, stick with Bussman and other high quality brands.

  • @mojo68mitch
    @mojo68mitch 3 ปีที่แล้ว +1

    What is the brand name of the defective breaker. There are a lot of them out there and a large range of pricing

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      Hi Mitch. It's generic. If you see the exact same housing, lever, and reset button, regardless of color, avoid it. I posted a link where you can find other breakers. Thanks for watching!

  • @alkaabi95
    @alkaabi95 2 ปีที่แล้ว

    I have 2000w power inverter and I wand to install it on my car secondary battery . My question is what is better way install it with fuse or bussmann circuit breaker??

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Fuse is fine, size it properly and it will never blow.

    • @alkaabi95
      @alkaabi95 2 ปีที่แล้ว

      @@electronicsNmore what size of fuse should I use for 2000w inverter pure sine wave ?

    • @alkaabi95
      @alkaabi95 2 ปีที่แล้ว

      ??

  • @tommussington8330
    @tommussington8330 2 ปีที่แล้ว

    I'd be willing to all the red "braker" brass buss piece from 10 amps to 200. Use the same size material.

  • @citizengkar7824
    @citizengkar7824 8 หลายเดือนก่อน +1

    So, is anyone surprised that Chinese products don't operate anywhere near to spec.
    Great teardown. I always work off the premise, of 50% max., for any sizing of products. Would be interesting to see a comparison, between the good makes: bet they don't use brass, for conductivity.
    I've also bought non-insulated crimp terminals, from Amazon, that were Chinese. Guess what: they weren't plated copper, either. Plated brass; at best, with a low %, of copper. I could tell, by the colour: very pale.

  • @jimbaranski4687
    @jimbaranski4687 2 ปีที่แล้ว

    You were going to provide a link for the BMS?

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Hi there. Look in the video description area. Thanks

  • @Sylvan_dB
    @Sylvan_dB 3 ปีที่แล้ว +8

    Good to have this information! It confirmed my long suspicion of those nameless D.C. breakers that seemed to come from the seedy side of the car audio world. That scene is full of scum and hokum and these breakers fit right in.

  • @HomeDistiller
    @HomeDistiller 2 ปีที่แล้ว

    have you measured the voltage drop across the breaker?

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      No, but the level of heat generated indicates it would be a lot.

  • @WaschyNumber1
    @WaschyNumber1 3 ปีที่แล้ว +1

    🖖 👍 Very nice video.
    Does Anyone know a inet side, for brass, stainless steel, ect current ratings in Amps = mm2 🤔

    • @electronicsNmore
      @electronicsNmore  3 ปีที่แล้ว

      I'm sure you can find that online doing a search. Thanks for watching!

  • @billarroo1
    @billarroo1 2 ปีที่แล้ว +1

    Wow there is a lot wrong with this type breaker !, I was going to use 3 of them in my step van 70, 100, 200 amp. But now I'll use something else. ! 😃😃😃Thanks

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      Thanks for watching William! Be sure to look over my extensive video playlists below for many other videos of interest to you, and most importantly take one minute to share a link to my channel with others on social networking sites.
      th-cam.com/users/electronicsnmoreplaylists

  • @gabrielr6679
    @gabrielr6679 ปีที่แล้ว

    Why didn't u change the ground bigger as well?

  • @cheath8705
    @cheath8705 2 ปีที่แล้ว

    Those stud connection look tiny to handle 200amps. Is it smaller than 5/16? For such a large continuous current, I would imagine it should be at least ⅜".

    • @electronicsNmore
      @electronicsNmore  2 ปีที่แล้ว

      The look like they could handle around 80A, not 200A.

  • @markkyy59
    @markkyy59 2 ปีที่แล้ว

    I had one worked like a resitor turned on Off I thought my Inverter was broken was only letting 3 volts through took I while to work out as when on indicator lights turned on !!