  • @troyaudiotrslighting4603
    @troyaudiotrslighting4603 6 หลายเดือนก่อน

    MR-J2S-40b apakah bisa coneksi dengan mac3

    • @ThanhPhanvn
      @ThanhPhanvn  6 หลายเดือนก่อน

      MR-J2S-40b: is controlled via net, not Pulse. you check mac3 support ? Usulay, mac3 control pulse

    • @troyaudiotrslighting4603
      @troyaudiotrslighting4603 6 หลายเดือนก่อน

      @@ThanhPhanvn saya punya yang tipe MR-J2S-40b,mau bikin cnc,apakah bisa di aplikasikan buat cnc yang MR-J2S-40b,tolong bantuanya

    • @ThanhPhanvn
      @ThanhPhanvn  6 หลายเดือนก่อน

      @@troyaudiotrslighting4603 : NO. MR-J2S-40b can not use with MACH3 board. MR-J2S-40b: It is connected with a servo system controller or similar device via a serial bus (SSCNET). MACH3: control pulse

    • @ThanhPhanvn
      @ThanhPhanvn  6 หลายเดือนก่อน

      @@troyaudiotrslighting4603 : MR-J2S-40A ( series MR-J2S-A ) can connect to MACH3 . i do not know how to use MACH3.

  • @caonguyen9011
    @caonguyen9011 2 ปีที่แล้ว

    Em đang làm luận văn về con mr j2s 10b . Cho em hỏi nó khác gì vs j2s 10 a k ạ

    • @ThanhPhanvn
      @ThanhPhanvn  2 ปีที่แล้ว

      10b khác 10a:
      a: điều khiển bằng xung
      b: điều khiển từ mạng

  • @AnhNguyen-lw8kr
    @AnhNguyen-lw8kr 6 หลายเดือนก่อน

    Anh làm điều khiển động cơ step đc ko ạ

    • @ThanhPhanvn
      @ThanhPhanvn  6 หลายเดือนก่อน

      video kết nối động cơ bước
      th-cam.com/video/5ggzEpfPvqg/w-d-xo.html

  • @quano9613
    @quano9613 3 ปีที่แล้ว

    A ơi plc siemens kết nối với servo MR-J2S-10A được ko ạ?

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว

      Plc siemens điều khiển servo mr-j2s-10 được

    • @quano9613
      @quano9613 3 ปีที่แล้ว

      a làm video hướng dẫn dùng plc điều khiển đi a

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว

      @@quano9613 : anh không có thiết bị plc Siemens để làm video này

    • @quano9613
      @quano9613 3 ปีที่แล้ว

      ​@@ThanhPhanvn a làm plc mitshubishi cũng được e xem cách đấu nối và nhận xung chân nào ạ

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว

      @@quano9613 Em xem loatj bài điều khiển servo Mitsubíhi Mr-J2s-a
      th-cam.com/channels/FLTHp1_E-EQyUHBO1WcwIQ.htmlplaylists

  • @taihoang4348
    @taihoang4348 2 ปีที่แล้ว

    hi bác sao em dùng con mr j2 10b . đấu com chọn con chuẩn rồi mà sao nó vẫn báo lỗi không kết nối đc bác nhỉ

    • @ThanhPhanvn
      @ThanhPhanvn  2 ปีที่แล้ว

      Chào bạn,
      1. Bạn xem lại chọn cổng Com các bước theo đúng video
      2. Model thiết bị chọn Mr j2 10b

  • @nuacuocoi8664
    @nuacuocoi8664 3 ปีที่แล้ว

    A ơi dùng MR configua 2 để test được k ạ?

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว +1

      Để anh cài vào máy tính xem có test được không

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว +1

      Phần mềm MR configurator 2: dùng để cài đặt thông số, giám sát, kiểm tra servo J3, J4 trở lên tùy phiên bản của phần mềm
      Không sử dụng cho MR-J2S

    • @chusang3915
      @chusang3915 2 ปีที่แล้ว

      Anh ơi cho em hỏi phần mềm j2s có sử dụng cho j3.j4 được không

    • @nuacuocoi8664
      @nuacuocoi8664 2 ปีที่แล้ว

      @@ThanhPhanvn cảm ơn anh

    • @ThanhPhanvn
      @ThanhPhanvn  2 ปีที่แล้ว

      @@chusang3915 : không em ơi.
      Phần mềm J2S chỉ dùng cho servo MR-J2S

  • @MinhDanhTRAN-o1r
    @MinhDanhTRAN-o1r 4 หลายเดือนก่อน

    RESET NHÀ MÁY THÔNG SỐ NÀO VẬY BÁC

    • @ThanhPhanvn
      @ThanhPhanvn  4 หลายเดือนก่อน

      @@MinhDanhTRAN-o1r : dùng phần mềm reset factory được. Thông số cài đặt: mình không thấy.

    • @MinhDanhTRAN-o1r
      @MinhDanhTRAN-o1r 4 หลายเดือนก่อน

      @@ThanhPhanvn bác ra video reset nhà máy nữa thì hay quá

    • @ThanhPhanvn
      @ThanhPhanvn  4 หลายเดือนก่อน

      @@MinhDanhTRAN-o1r : trong video " dùng video cấu hình servo MR-J2S" có hướng dẫn reset thông số

  • @thuylo5618
    @thuylo5618 4 ปีที่แล้ว

    Em có servo MR-J2S 100A 1kw hỏng em muốn thay thế bằng MR-J2S 200A 2kw có được không anh?

    • @ThanhPhanvn
      @ThanhPhanvn  4 ปีที่แล้ว

      Trường hợp 1: Bộ MR-J2S 100A 1kw: nếu em giữ lại bộ drive ( điều khiển ) mà thay bằng motor của MR-J2S 200A 2kw thì không được vì motor công suât lớn hơn
      Trường hợp 2: thay nguyên bộ ( servo và điều khiển ) MR-J2S 100A 1kw bằng bộ MR-J2S 200A 2kw : em xem có tương thích về kích thước motor với cơ cấu cơ khí, mặt bích lắp đặt không trước khi sử dụng

    • @thuylo5618
      @thuylo5618 4 ปีที่แล้ว

      @@ThanhPhanvn chỉ thay mỗi sẻvo thôi giữ lại moto dc ko anh?

    • @ThanhPhanvn
      @ThanhPhanvn  4 ปีที่แล้ว

      @@thuylo5618 : Em liên hệ hãng Mitsubishi để có câu trả lời chính xác vì anh thường sử dụng bộ servo và motor cùng công suất: vì motor có encoder điều khiển vòng kín, bộ điều khiển và motor phải có bộ thông số tốt, tương thích hoàn toàn để điều khiển vị trí chính xác cao và đáp ứng nhanh

    • @ThanhPhanvn
      @ThanhPhanvn  4 ปีที่แล้ว

      Anh xem tài liệu Mitsubishi thì không dùng: bộ điều khiển servo công suất lớn 2kw kết nối servo 1 kw

    • @thuylo5618
      @thuylo5618 4 ปีที่แล้ว

      @@ThanhPhanvn vâng em cảm ơn

  • @propovednik_e53
    @propovednik_e53 3 ปีที่แล้ว

    Where is others i/o digital pins in i/o monitor???

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว

      you view below video:
      1. Wiring for servo
      th-cam.com/video/fvuybJaMha0/w-d-xo.html
      2. PLC FX1S control servo
      th-cam.com/video/9bgNAaf6Brc/w-d-xo.html

  • @jesusalejandrogerardoalvar809
    @jesusalejandrogerardoalvar809 3 ปีที่แล้ว

    At minute 18:01 a message is observed about an error in the communication between the computer and the servo amplifier, what is the cause of this message and how did you solve it?
    Very kind
    Greetings

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว

      Select number of COM: wrong
      Select Servo drive: model is wrong
      Cable: connection is wrong
      drive is power off

    • @jesusalejandrogerardoalvar809
      @jesusalejandrogerardoalvar809 3 ปีที่แล้ว

      @@ThanhPhanvn
      Hi Thanh Phan.
      I have checked the COM port number in the device manager, I just need to know if I have it properly configured.
      This is my configuration:
      Bits per second: 9600
      Data bits: 8
      Parity: None
      Stop bits: 1
      Flow control: None
      If I have something wrong, I would appreciate it if you could help me.
      My Servo drive model in the software matches the physical model.
      Check continuity in my cable that goes to CN3 as indicated in the video at minute 2:14 and I have continuity on all pins.
      My servo drive is on.
      I still can't make the connection.
      Won't it be my windows?
      What version of Windows do you have?
      I can send you a video of all this.
      Would you like to see it?
      Thanks for the attention
      Best Regards

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว

      @@jesusalejandrogerardoalvar809
      Windows win7 64 bit
      Video 7:23: device manager COM8.
      station system: 8
      If your compuet show USB to serial com port , cable is OK and computer is OK
      Give me your model ?
      In video: model MR-J2S-A
      I show detail in this video.

    • @ThanhPhanvn
      @ThanhPhanvn  3 ปีที่แล้ว

      @@jesusalejandrogerardoalvar809
      Send me: error message
      or video to my facebook
      bit.ly/2QOFXWy