Elevator Fire Service Demo (All Phases)

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ก.ค. 2024
  • Demo of the basic fire service features we as technicians and inspectors have to check on a regular basis on any passenger or service elevator. Most of these features are often interfaced with the buildings fire alarm system or as is the case in this video, have a separate FACP dedicated specifically to these functions.
    Follow me on Twitter & Instagram!
    TWITTER: / safetech0415
    INSTAGRAM: / officialsafetech
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 68

  • @flightlevel3608
    @flightlevel3608 ปีที่แล้ว +5

    3:20 You don't need to leave the key in the "Reset" position. Just turn it to "Off" after resetting for a second or two and the system will complete the cycle itself, even if the elevator is recalling to a different floor during reset.

  • @michaelglissonjr9490
    @michaelglissonjr9490 6 ปีที่แล้ว +4

    Now this is cool. Nice job!

  • @chrisgonzalez5684
    @chrisgonzalez5684 3 ปีที่แล้ว +3

    Good job you did a nice work

  • @davidredpath4781
    @davidredpath4781 6 ปีที่แล้ว +7

    Great video!

  • @jonahladuke7607
    @jonahladuke7607 2 ปีที่แล้ว +1

    Well at least I know how to operate an elevator in case of emergency great instructional video I appreciate it I'm going to save it

  • @brianthetowerguy979
    @brianthetowerguy979 6 ปีที่แล้ว +2

    This was awesome !

  • @relevanteaglealarms109
    @relevanteaglealarms109 4 ปีที่แล้ว +3

    It’s is likely an nudge mode during fire mode.

  • @DatamasterCorporation
    @DatamasterCorporation 4 ปีที่แล้ว +5

    They really should make that indicator say, 'Please exit when doors open' I don't think most people would understand what that symbol means.

    • @h-aandle
      @h-aandle ปีที่แล้ว

      PL
      EA
      SE
      EX
      IT
      TH
      E
      EL
      EV
      AT
      OR
      WH
      EN
      TH
      E
      DO
      OR
      S
      OP
      EN

    • @h-aandle
      @h-aandle ปีที่แล้ว +2

      actually wait on some other otises like the series 1 it does say it

    • @IanGSully
      @IanGSully ปีที่แล้ว +1

      @@h-aandle Most elevators that talk do

    • @flightlevel3608
      @flightlevel3608 ปีที่แล้ว +1

      This elevator is not equipped with a vocab feature since it's not a mid to high rise building. If it was, it would say that.

  • @toddthegamer
    @toddthegamer 6 ปีที่แล้ว +16

    That elevator sounds like it has a dover buzz

    • @smartyblooper4141
      @smartyblooper4141 6 ปีที่แล้ว +2

      but on newer thyssenkrupp has grocery store beep

    • @GardenStateElevators
      @GardenStateElevators 6 ปีที่แล้ว +3

      Samantha LindenbaumFinch All Otis elevators from the early 1980’s to present have these buzzers for nudge mode and fire service.

    • @smrtc651productions
      @smrtc651productions 5 ปีที่แล้ว +2

      and series 1

    • @toddthegamer
      @toddthegamer 4 ปีที่แล้ว +2

      @NeedNova oh ok

  • @ruthdelgado6748
    @ruthdelgado6748 6 ปีที่แล้ว +2

    not always but some ev you have to enabele to enable phase 1

  • @WheeloveFireAlarms
    @WheeloveFireAlarms 6 ปีที่แล้ว +3

    Awesome! I never knew how that worked! That’s really cool.

  • @Kasey1776
    @Kasey1776 6 ปีที่แล้ว +4

    Cool!

  • @user-tw4vi3uv1r
    @user-tw4vi3uv1r 2 หลายเดือนก่อน

    @safetech An elevator should never be recalled by a manual pull station or detectors in other facility areas unless specified by the AHJ. IS THERE A REASON FOR THIS.

  • @seanjuth
    @seanjuth 3 ปีที่แล้ว +2

    It's weird how when you activated the smoke detector in the machine room the elevator re-leveled

  • @blue.light.fazbear
    @blue.light.fazbear 6 ปีที่แล้ว +1

    What is the buildings main system

  • @seanjuth
    @seanjuth 3 ปีที่แล้ว +1

    Did you have to access the hoistway in order to test the smoke detectors in the shaft? I see you have a full set of Otis keys, but obviously due to how dangerous it is, you probably wouldn't want to be filming, in fear of simplex seeing this.

  • @twentyfour44
    @twentyfour44 6 ปีที่แล้ว +7

    What type of alarms were there and how did you disable them on a 4006

    • @ShaunPuzon
      @ShaunPuzon 6 ปีที่แล้ว +1

      He said in the description that this building has a separate FACP dedicated to the elevator system. There may not have been any notification appliances connected to that panel.

  • @VOLTRONDEFENDER4440
    @VOLTRONDEFENDER4440 5 ปีที่แล้ว +1

    The door close button is a different kind it was probably replaced because the other one doesn’t work

  • @seanjuth
    @seanjuth 3 ปีที่แล้ว +1

    It looks like Otis didn't properly adjust the auxiliary recall functionality

  • @Jamestube8439
    @Jamestube8439 6 ปีที่แล้ว +5

    The first test for when the elevator moved to the 2nd floor, how do you reset it? With the phase l fire key switch on floor 1

    • @safetech
      @safetech  6 ปีที่แล้ว +3

      That is correct. Fire service mode can be cleared after the initiating device that tripped it has been reset.

    • @Jamestube8439
      @Jamestube8439 6 ปีที่แล้ว +2

      Ok, thanks

    • @Jamestube8439
      @Jamestube8439 6 ปีที่แล้ว +2

      Awesome, I'll check it out.

  • @nickday1984
    @nickday1984 6 ปีที่แล้ว +1

    Yes

  • @josepeixoto3715
    @josepeixoto3715 2 ปีที่แล้ว +1

    FACP?
    got it: Fire Alarm Control Panel

  • @212Elevators
    @212Elevators 2 ปีที่แล้ว +1

    If the heat detector in the machine room is activated before the smoke or the smoke in the shaft activates, what does it do?

    • @frazierg0325
      @frazierg0325 ปีที่แล้ว +1

      Recalls to designated floor.

  • @jorgeburgos3405
    @jorgeburgos3405 3 ปีที่แล้ว +1

    The elevator is a Otis Series 5

  • @jorgeflores9381
    @jorgeflores9381 3 ปีที่แล้ว +3

    Question to all fire alarm experts, does turning on fire service trigger a response from the fire department?

    • @safetech
      @safetech  3 ปีที่แล้ว +2

      Not from what i’ve seen by turning the fire service key. However some elevators may have some special configurations to do so.

    • @frazierg0325
      @frazierg0325 ปีที่แล้ว +1

      NO

    • @flightlevel3608
      @flightlevel3608 11 หลายเดือนก่อน +1

      Using elevator fire service as a standalone (test and demo) will not trigger a response from the fire department. However, if the FACP is programmed it will send a signal if the entire building alarm system is triggered.

  • @Emmisullivan14
    @Emmisullivan14 5 ปีที่แล้ว +1

    What happens if the smoke detectors are triggered on both floors and there's a fire on both floors at the same time?

    • @edgarmartinez7371
      @edgarmartinez7371 4 ปีที่แล้ว +2

      In situations in which smoke detectors are triggered on all floors, most elevators will send a signal to the machine room and the fire alarm control panel to 'shunt trip (or disable)'; the only form to restore its memory is resetting the FACP and the machine switch

  • @embeddedgirl
    @embeddedgirl 6 ปีที่แล้ว +1

    Any particular reason why you would want to deticate an entire 4008 just for the elevator? My guess would be to keep programming simple on the main panel. Though regardless of how many floors the elevator services it'd be overkill for 2 or 3 floors, and redundant for 8-12 floors being that's it'd just be easier to program that into the main panel. (Most likely a 4100 series and at that point it's going to take more than a day to program anyway)

    • @safetech
      @safetech  6 ปีที่แล้ว +2

      This facility does not have a main fire alarm therefore the 4008 is in place for the elevator safety controls and as a means to dial out to monitoring.

    • @embeddedgirl
      @embeddedgirl 6 ปีที่แล้ว +1

      SAFETECH ahhh ok, that makes more sense now. Thanks!

    • @frazierg0325
      @frazierg0325 ปีที่แล้ว +1

      Some occupancies don't require a fire alarm so the panel is for recall only.

  • @relevanteaglealarms109
    @relevanteaglealarms109 4 ปีที่แล้ว +1

    Otis series 5

  • @OSMDRG91TA
    @OSMDRG91TA 6 ปีที่แล้ว +2

    Dover Buzz.

  • @shanihowell2327
    @shanihowell2327 4 ปีที่แล้ว +1

    It looks like a otis gen2 and series 5

  • @Aaronproductions
    @Aaronproductions 6 ปีที่แล้ว +3

    Nice man, I love watching what it’s like to be a tech. Does Simplex give you permission to upload these videos? Just wondering Because somone uploaded Simplex videos and the company fired them before.

    • @safetech
      @safetech  6 ปีที่แล้ว +6

      Aaron Productions
      Thanks for viewing and for your comment. I would first like to ask where in fact you got the information regarding what your claiming happened? Also, I respect all rights to privacy and never will you see me recording in unauthorized settings or areas not accessible to the general public. All location information is withheld. This is strictly an educational platform. Other than that, anyone has a right to film as long as these guidelines are adhered to and the setting allows for it. Only does it become a problem when careless people start to invade others personal space.

    • @Aaronproductions
      @Aaronproductions 6 ปีที่แล้ว +2

      SAFETECH there was a youtuber called “MRTRUEALERT” who had lost his Simplex panels and devices because he released them too early to the public. That’s why he doesn’t upload anymore. And I wasn’t expecting a paragraph about basic laws, I was just asking if your employer is ok with you filming at their costumers buildings. You went in the elevator room which isn’t “assessable to the public” nor eare any of the panels you show so I’m not sure what you were trying to say with that. Sorry I just wrote a big argument essay. Lol I like your videos so keep it up!

    • @safetech
      @safetech  6 ปีที่แล้ว +4

      Aaron Productions.
      You are correct in what you are saying. And no I don’t usually need permission to film because I am not leaking private or personal info. That’s where this whole issue begins.Therefore I feel it isn’t warranted. Like I said before, my vids are for educational purposes. If a privacy concern arises the content will be modified or deleted altogether as I have accidentally ran into that a few times myself in the past.

    • @bellum128
      @bellum128 6 ปีที่แล้ว +1

      Aaron Productions
      +Aaron Productions What is your source for this? I was trying to find more information on where MrTrueAlert went, but couldn't.

    • @Aaronproductions
      @Aaronproductions 6 ปีที่แล้ว +1

      bellum128 he uploaded it to the fire panel forms I believe, but it may have been removed

  • @twentyfour44
    @twentyfour44 6 ปีที่แล้ว +3

    Shouldn't it be recalled to the lobby

    • @gnutelliums
      @gnutelliums 6 ปีที่แล้ว +4

      If the smoke detector on the second floor tripped, then yes. But since the detector in the lobby tripped, it won't recall to the same floor that the alarm is on. A fire on the second floor would've triggered primary recall, but the ground floor is the alternate recall.

    • @212Elevators
      @212Elevators 3 ปีที่แล้ว +2

      @@gnutelliums What about the detector in the shaft?

    • @IanGSully
      @IanGSully ปีที่แล้ว +1

      @@212Elevators It will do the same thing if the smoke detector in the machine room goes into alarm. It will cause the “Firefighter hat” indicator that is in the elevator to flash.

    • @212Elevators
      @212Elevators ปีที่แล้ว +1

      @@IanGSully Hence why it says to exit the elevator when that happens?

  • @casualgamer24
    @casualgamer24 6 ปีที่แล้ว +2

    why don't u ever talk in your videos? just wondering
    not to be mean but I just want to hear what u sound like

    • @Bill-bj9fn
      @Bill-bj9fn 6 ปีที่แล้ว +2

      Evan The gamer Some small youtuber I think SER safety does an interview on this guy

    • @Corvette1658
      @Corvette1658 4 ปีที่แล้ว +1

      And he does talk when he tests voice evc system. Like making the announcements telling everyone that we will be testing the fire alarm system.

  • @HungTrinh-hd8xv
    @HungTrinh-hd8xv 7 หลายเดือนก่อน

    EMERGENCY RECALL