Excellent demonstration of the myth of power savers. I do not understand your native language, but the numbers do not lie. I am a retired electrical engineer, and I have done my utmost to discredit the rampant myth that these so called power savers work. Kudos to you on your very complete demonstration, keep up the good work! Ordinary people just do not understand real power versus apparent power and what a power factor really is. It very apparent that the consensus of the educated around the globe that this a total scam, and absolutely must be quashed. You are a brother from another country. Cheers from Canada.
Remove your Bulb (Resistive load ) First During Test Check you capacitor also It WORKS on inductive load only... like motors, Water pump. Fan .drill, transformers,Washing machine & other home appliance Ok ? and depends on condition of Power factor at your premises.
1000 % Right Video kahi par bhi Ye Video nai mila with proper practical. I'm also electrical person... DAD ne power saver laya he mene nikal diya Tha. 1. Wo khud power khata he effect kuch nai deta 2. Khud charge hota he hame iski jyada Jarurat naiye. 3. logo ko bechneka kam krte he sirf
Capacitor is used for correction of power factor of inductive loads. Energy usage is billed in KWH and not KVAH... KwH = kvah * cos (phi) Cos(phi) is between 0.0 and 1.0 depending on type of load. Correcting cos(phi) with a capacitor will make it 1.0 thereby increasing KWH. In fact you don't save current, instead you lose some with the internal resistance of capacitor
@@keep-updating-keep-exploring do not use capacitor or inductor to correct power factor with out exact knowledge of type of load. You will end up in additional electric bill. You can use an Automatic power factor corrector (APFC) if you have a big load with more motor type loads ( inverter motors don't count) and provided the billing at your place is in kvah. (Here in Kerala, india billing is in KWH)
جی بھائی آپ نے بہت اچھی ویڈیو اپلوڈ کی ہے۔ میں بھی اس طرح کی ویڈیوز اپلوڈ کرنے کا ارادہ رکھتا ہوں جو بیمار عوام کے لیے ایک جھٹکا ہو۔ لوگ اس لیے ایسی ویڈیوز پر کلک کرتے ہیں کہ وہ مصیبت کے مارے اس چکر میں ہوتے ہیں کہ کوئی طریقہ مل جائے بجلی کا بل بچانے کا یا نہ دینے کا ۔ اور آپ کی کلک بیٹ وہ سارا کمال کر دیتی ہے ۔
@@amolsert हाय भाई आपने बहुत अच्छा वीडियो अपलोड किया है। मैं उन वीडियो को भी अपलोड करने की योजना बना रहा हूं जो बीमार जनता के लिए एक झटका हैं। लोग ऐसे वीडियो पर क्लिक करते हैं क्योंकि वे बिजली बिल को बचाने या भुगतान करने का तरीका खोजने के लिए दुविधा में हैं। और आपकी क्लिक बीट यह सब करती है। Upar yeh sab likha hai bhai ne uska maine hindi me translate kar diya h
Normally you can check the current consumption in inductive loads after connecting capacitor. Watt never changes but VA must change by connecting capacitor. Most household meters read one unit as one kVAh insted of kWh so in that case capacitor is helpful in case of more inductive loads only otherwise kVAh will increase.
Excellent video. You have given great lesson to people and companies fooling people. Such devices are very common and ordinary people think of them like God blessing as they claim to cut off bill for great extent. Wonderful experimentation. I am also planning to upload such kind of video to aware my sucbrsibers and viewers for such bloody foolish items.
A combination of Resistor and Capacitor can be used in parrallel connection with mootorised items like fans and drills and washing machines. It will not save power but it will improve efficiency of equipment. Motors of all equipment will run slightly faster. And the resistor is actually not required at all. Just a capacitor used in fans will do. That is why your fan speed becomes slow or stops when its capacitor stops functioning. And I have not seen the pwer monitor in the market, which is shown in video.
I see this Video but the capacitor was too low...this cap have 1.40 and the Lamp 66 watt so i see Lamp with cap show the Display 65 watt!Before without cap 66 watt and with cap 65 watt!You want 4.00 mfd cap 400 v this will save energy this is for 1000w and you can try this...
The energy meter works on current consumed by load. After putting capacitor the inductive part shall be compensated and current drawn by load shall be decreased hence the power consumed by inductive loads shall be decreased. It will be connected along with high inductive load. Not always in circuit, then it will also be a electrical load and consumed power. Regards
Yes, You are right Power saver which are available in market are totally ford for single phase user. In three phase power there is a panelty for low power factor hence APFC or FPC (CAPACITOR) Bank improve power and reduce Bill ...
You have used 1 mfd capacitor but what Voltage ? Is it 440 Volt ?... Very nicely explained ! You cannot save power by such device or rather any device. Use star rated AC Fridge or Fans to save power !
Only one explanation from this video that Capacitor only makes filtration of current and reduces micro fluctuations to give constant power to the device.
Thanks a lot for this video. I had decided to purchase a power saving device before seeing your video. Now I will not do that . Thanks once again for making people aware against this fraud.
This is called bleeding resistor. If you do not connect it, the capacitor will retain the charge and give lethal shock when touched. The resistance draws negligible current when connected in parallel but comes into picture when electricity is switched off.
Agar tum English language mein kamzor ho,to Hindi Jo hamari Matrabhasha Hain,uska prayog Karo. Ab baat karte Hein power saver ki,Hamare Ghar me jha par bhi chowk ya transformer ya coil hogi,vahan hamara POWER FACTOR bigdega. Lekin Ghar me agar hum usay correct bhi kar dein power factor panel laga kar,to bhi Chand rupees ki bachat hogi. Power saver,sirf moorkh banane ka tarika Hain. Agar bijli ka bill kam ho jata to,phir to badi electrical gadget makers,bana kar market mein bech rahe hote.
Actually not for led or such efficient devices.... If power factor is high like 0.8 or0. 9 there is no need... Only for old devices or devices which do not have capacitors u need it... Great video
Brother u have to calculate the capacitance exactly to compensate for reactive power used by induction loads.... only then it will work... also in your case inductive load is not much as compared to resistive...
हाय विजयभाई मेरा नाम दिलीप मोरे है मैने आपका विडीओ देखा बहुत बहुत अच्छा लगा और मैने कमसे कम ५०. दोस्तोको शेर कीया मुझे आपका विडीओ बनानेका जो तरीका हे बहुत अच्छा लगता है मै आपकी सभि विडीओ देखता हुं और बनाता भि हु मेरी एक रीक्वेस्ट हे एक ऐसी सरकीट बनाके दखाये जो एक से ४० ५० वोल्टतक चले और हा एसि टु डीसी पावर सप्लाय हो धन्यवाद जय शंकर
A very good demo of the power saver which we should not use. Nowadays fakers are at large. Never use these types of gadgets. You only waste your money.
phele me dislike karne wala tha kyonki muje pata he ki ye device bekar he per pura dekhene ke baat aab like kar diya he , power meter resistive power ko calculate karta he na ki apparant power ko or yahi per log dokha kha jate he or unko lagta he ye power save kar ta he
No it's not true plz go through G K Agarwal videos. U have to understand about indictive and resistive. Aapne Jo bhi load Diya unka PF Ok Tha so wo improve nahi huwa. Jiska PF 1 or .99 se kam hoga uspar hi capacitor will work.
Sir you add resistance between two wire of capacitor that's why it's not work. Second if power factor already equal to 1 than it can't be improve it's optimum value .
Many of the similar videos increases the electricity bill. This can improve the power factor. But there should be a reactive load. Otherwise it will increase the bill.
Hello sir aap ka video Dekhkar mujhe bahut accha laga jitne company power saver banate hain Sabhi company public co chutiya banati hai Toh Phir sir Aisa Koi power save Aap Hume bataiye Aisa Koi power save hai kya Jo Bijli bill kam kar sake thank you sir bahut bahut dhanyavad
Thanks a lot, aapke videos mujhko shuru se he bahut pasand hai. Aap ne bilkul sach kaha capacitors lagane se kuch nahi hoga. Sir aap he koi power saver device bana ker dijiye. Waise bhi india mein parallel mein connect hone wale capacitors nahi milte, agar iss tarah se connect karege to capacitor burst ho jayaga overcharge ki wajah se.
Because adding cap bank wil only decrease VARs, not kW. Billing is done on kW, if it was done on kVA only then cap bank wud have decreased electricity bills.
This is not power saver , it is a starting capacitor used at fan or motor and it's rating is in micro farad or MFD. If u use Power capacitor with KVAR rating according to your house current load then u will get result.
I think only watchfullness conciousness and proper use of applances and equipments can help reduce electric power consumption. 😊plus a knowledge of electrical formulas like ohms law etc .
Good informative ! What that device you using to measure the watts with multiple switches it's having ? Please give the name of the meter & available link.
Dosto, comment bahut jaruri hai or ye video aap ko kesa laga jarur bataye!!!!💖💖💖✌👍
если ты отвечаеш мне на русском создай себе русский канал
change headline of video
Very nice
Is link ki kya reality hai..mujhko to ye video fake lagti h main link de raha hu
th-cam.com/video/IqliOtwp_DQ/w-d-xo.html
Very nice video ., Sir 24v ka auto cut off charger banaiye
Excellent demonstration of the myth of power savers. I do not understand your native language, but the numbers do not lie. I am a retired electrical engineer, and I have done my utmost to discredit the rampant myth that these so called power savers work. Kudos to you on your very complete demonstration, keep up the good work! Ordinary people just do not understand real power versus apparent power and what a power factor really is. It very apparent that the consensus of the educated around the globe that this a total scam, and absolutely must be quashed. You are a brother from another country. Cheers from Canada.
You are absolutely right brother.
Remove your Bulb (Resistive load ) First During Test Check you capacitor also It WORKS on inductive load only... like motors, Water pump. Fan .drill, transformers,Washing machine & other home appliance Ok ? and depends on condition of Power factor at your premises.
How to check power factor?
Ur right brother
बहुत अच्छा जानकारी वाला वीडियो है। पावर सेवर लगाने का कोई फायदा नहीं उल्टा नुकसान हो सकता है। अच्छी जानकारी देने के लिए बहुत-बहुत धन्यवाद ।
1000 % Right Video kahi par bhi Ye Video nai mila with proper practical.
I'm also electrical person...
DAD ne power saver laya he mene nikal diya Tha.
1. Wo khud power khata he effect kuch nai deta
2. Khud charge hota he hame iski jyada Jarurat naiye.
3. logo ko bechneka kam krte he sirf
Zabdast ...bahot hee NAIK kaam ...
LOGO ko dhokey say bachayaa...
Hats of you....
Capacitor is used for correction of power factor of inductive loads.
Energy usage is billed in KWH and not KVAH...
KwH = kvah * cos (phi)
Cos(phi) is between 0.0 and 1.0 depending on type of load.
Correcting cos(phi) with a capacitor will make it 1.0 thereby increasing KWH.
In fact you don't save current, instead you lose some with the internal resistance of capacitor
👍👍👍
👍
Bro my electric bill meter showing -0.958 PF without inductive load and on inductive load it is showing 0.8 or 0.9 is it ok ???
@@keep-updating-keep-exploring do not use capacitor or inductor to correct power factor with out exact knowledge of type of load. You will end up in additional electric bill.
You can use an Automatic power factor corrector (APFC) if you have a big load with more motor type loads ( inverter motors don't count) and provided the billing at your place is in kvah. (Here in Kerala, india billing is in KWH)
@@MrCool-vi9wh nope here also billing kwh
Very many thanks to you to alert us from being cheated. Not only that, also with a solid proof. Hat's off to you. ❤👍🙏🏼🇮🇳
جی بھائی آپ نے بہت اچھی ویڈیو اپلوڈ کی ہے۔ میں بھی اس طرح کی ویڈیوز اپلوڈ کرنے کا ارادہ رکھتا ہوں جو بیمار عوام کے لیے ایک جھٹکا ہو۔ لوگ اس لیے ایسی ویڈیوز پر کلک کرتے ہیں کہ وہ مصیبت کے مارے اس چکر میں ہوتے ہیں کہ کوئی طریقہ مل جائے بجلی کا بل بچانے کا یا نہ دینے کا ۔ اور آپ کی کلک بیٹ وہ سارا کمال کر دیتی ہے ۔
English me likho Bhai kuch to samaz me aaye
@@amolsert हाय भाई आपने बहुत अच्छा वीडियो अपलोड किया है। मैं उन वीडियो को भी अपलोड करने की योजना बना रहा हूं जो बीमार जनता के लिए एक झटका हैं। लोग ऐसे वीडियो पर क्लिक करते हैं क्योंकि वे बिजली बिल को बचाने या भुगतान करने का तरीका खोजने के लिए दुविधा में हैं। और आपकी क्लिक बीट यह सब करती है।
Upar yeh sab likha hai bhai ne uska maine hindi me translate kar diya h
VERY nice video sir ji..... i always like your video and your practical demonstration....
Many many thanks
Normally you can check the current consumption in inductive loads after connecting capacitor. Watt never changes but VA must change by connecting capacitor. Most household meters read one unit as one kVAh insted of kWh so in that case capacitor is helpful in case of more inductive loads only otherwise kVAh will increase.
Normally in houses we use single phase 1/2 hp, or 1 hp sump motors or submersible and 3 pH submersible motors . These are inductive loads.
While we apply capacitor bank across load pf increases while current reduced but product of V.I .pf remains constant fake video
Right you are sir
U r Right
Bahot achhe se described kia he brother ....bahut achha laaga
good lesson to every one Bro ....keep it up
Very much appreciated work
Sachhai dikha di
Wrna kai log propaganda chala ke sell karwa rhe hai
Bahut dhanyavaad
Excellent video. You have given great lesson to people and companies fooling people. Such devices are very common and ordinary people think of them like God blessing as they claim to cut off bill for great extent. Wonderful experimentation. I am also planning to upload such kind of video to aware my sucbrsibers and viewers for such bloody foolish items.
I absolutely agree with you. It seems that this is not just a pet peeve for me alone. Cheers from Canada.
Very good. informative video. Thanks.
A combination of Resistor and Capacitor can be used in parrallel connection with mootorised items like fans and drills and washing machines. It will not save power but it will improve efficiency of equipment. Motors of all equipment will run slightly faster. And the resistor is actually not required at all. Just a capacitor used in fans will do. That is why your fan speed becomes slow or stops when its capacitor stops functioning. And I have not seen the pwer monitor in the market, which is shown in video.
Very good demonstration for the Game changer.
your title is wrong. basically you want to sAY DONOT USE POWER SAVER.
ऎसा लिखते तो कोई भी देखता नही,
@@a93282 sach hey
I see this Video but the capacitor was too low...this cap have 1.40 and the Lamp 66 watt so i see Lamp with cap show the Display 65 watt!Before without cap 66 watt and with cap 65 watt!You want 4.00 mfd cap 400 v this will save energy this is for 1000w and you can try this...
Thanks For Your Nice Information... Jay Jagannath...
Power saver definitely work in heavy inductive load but not in led like load
Proov kijiye sir practicaly like that.
@@chahal7114ਚਹਿਲ ਸਾਹਬ ਇਹ ਸਹੀ ਕਹਿ ਰਹੇ ਨੇ, ਵੀਡੀਓ ਬਣਾਉਣ ਵਾਲੇ ਨੂੰ ਪਾਣੀ ਵਾਲੀ ਮੋਟਰ, ਵਾਸ਼ਿਂਗ ਮਸ਼ੀਨ ਵਗੈਰਾ ਨਾਲ ਇਹ ਪ੍ਰੈਕਟੀਕਲ ਕਰਕੇ ਦਿਖਾਉਣਾ ਚਾਹੀਦਾ ਸੀ
Very good work for humanity and save extra money for every one thanks
The energy meter works on current consumed by load.
After putting capacitor the inductive part shall be compensated and current drawn by load shall be decreased hence the power consumed by inductive loads shall be decreased.
It will be connected along with high inductive load. Not always in circuit, then it will also be a electrical load and consumed power.
Regards
Yes, Sir, You are absolutely correct.
Bahut hi sunder tarike se bataye ho bhai.
Yes, You are right Power saver which are available in market are totally ford for single phase user. In three phase power there is a panelty for low power factor hence APFC or FPC (CAPACITOR) Bank improve power and reduce Bill ...
Totally correct! Cheers from Canada.
Very informative video.. Thanks.. 👍
It will effect on induction load only like motors, drill, transformers & other home appliance with this items. It is a proven long back before.
For 1 hp water pump motor, 50 micro farad capacito ok...woll not demage motor?
Awesome work brother
Thankyou
Thanks bhaiya itana bada fact batane ke liye I like this types of video which have real fact are available .
You have used 1 mfd capacitor but what Voltage ? Is it 440 Volt ?... Very nicely explained ! You cannot save power by such device or rather any device. Use star rated AC Fridge or Fans to save power !
Great information sir 100 topo ki salami aapko
Only one explanation from this video that Capacitor only makes filtration of current and reduces micro fluctuations to give constant power to the device.
Thanks a lot for this video. I had decided to purchase a power saving device before seeing your video. Now I will not do that . Thanks once again for making people aware against this fraud.
मैंने घर में दस लगा रखे हैं बिजली वाले उल्टा मुझे पैसे देने आते हैं 😂😂😂😂😂😂😂😂
Hello Really kya
😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😭😂😂😂😂😂😂😂😂😂😝😝😝😝😝😝😝😝😜😜😜😜😜😜😜😜😜😉🙃🙃🙃🙃🙃🙃🙃🙃🙃
Bijli wale tera mama
Tu uska bhanja
Good information bro I am very happy You saved me from being cheated.
Thnks for guiding man
Thanks Vijayesh ji.
main bhi kharidhne wala tha yeh device.
Highly informative video.
Nice Explanation 👌👌
Thank you
You have connected 1m ohm resistance parallel to capacitor which nullnify the capacitor effect to control power factor. You are wrong
The resister has practically no effect. All those power reducing videos are scam. Infact it will only increase your bill.
This is called bleeding resistor. If you do not connect it, the capacitor will retain the charge and give lethal shock when touched. The resistance draws negligible current when connected in parallel but comes into picture when electricity is switched off.
Thank you for information. God bless you.
Thank you
Well done. Good show. You are absolutely right.
Good directional video, kuch nahi hota hai sirf sab market me fraud bhare hi
Agar tum English language mein kamzor ho,to Hindi Jo hamari Matrabhasha Hain,uska prayog Karo.
Ab baat karte Hein power saver ki,Hamare Ghar me jha par bhi chowk ya transformer ya coil hogi,vahan hamara POWER FACTOR bigdega.
Lekin Ghar me agar hum usay correct bhi kar dein power factor panel laga kar,to bhi Chand rupees ki bachat hogi.
Power saver,sirf moorkh banane ka tarika Hain.
Agar bijli ka bill kam ho jata to,phir to badi electrical gadget makers,bana kar market mein bech rahe hote.
Sumit Khandelwal aba wo hindi basha hi bol rha ha tujha kahan sa lga ka english ha tou na pi tou ni rakhi😂😂😂
asi jakas video bnai londay na dil khus kr dia
Actually not for led or such efficient devices.... If power factor is high like 0.8 or0. 9 there is no need... Only for old devices or devices which do not have capacitors u need it... Great video
thanks bro i never recomend this type of gadgets.
Good job....thanks for the information
Brother u have to calculate the capacitance exactly to compensate for reactive power used by induction loads.... only then it will work... also in your case inductive load is not much as compared to resistive...
Good boy ,good job. Up ka bat atcha lagta hai.
हाय विजयभाई मेरा नाम दिलीप मोरे है मैने आपका विडीओ देखा बहुत बहुत अच्छा लगा और मैने कमसे कम ५०. दोस्तोको शेर कीया मुझे आपका विडीओ बनानेका जो तरीका हे बहुत अच्छा लगता है मै आपकी सभि विडीओ देखता हुं और बनाता भि हु मेरी एक रीक्वेस्ट हे एक ऐसी सरकीट बनाके दखाये जो एक से ४० ५० वोल्टतक चले और हा एसि टु डीसी पावर सप्लाय हो
धन्यवाद
जय शंकर
Thank you. दिलीप भाई
Very good job. Thank you
Will this capacitor help in reducing flicker in home lighting when appliances like refrigerator or A/C start?
no
Aap ka video achha laga, superb👌
As We know the Truth,Now Tell us the right Way to save money
Eat and drink less
A very good demo of the power saver which we should not use. Nowadays fakers are at large. Never use these types of gadgets. You only waste your money.
Are yaar ap engineering karlo bhai.fir batao duniya ko😁😁😁😁😁😁
😊Great so so so honesty😊
😊😊😊😊 Keep going 😊😊😊😊😊
you and your powersaver wrong but not all power saver
Ekdam achha laga mera dout clear ho gya sir
phele me dislike karne wala tha kyonki muje pata he ki ye device bekar he per pura dekhene ke baat aab like kar diya he , power meter resistive power ko calculate karta he na ki apparant power ko or yahi per log dokha kha jate he or unko lagta he ye power save kar ta he
Very good information. Thank you so much
Please change the title of video
what should be it
Kesy
Title should be "power saver scam exposed with proof"
Bijali ka bil Kam nahin Karega sar ji aapane bahut acchi tarah se samjhaya aapka thank u shukriya dhanyvad
No it's not true plz go through G K Agarwal videos. U have to understand about indictive and resistive. Aapne Jo bhi load Diya unka PF Ok Tha so wo improve nahi huwa. Jiska PF 1 or .99 se kam hoga uspar hi capacitor will work.
I agree... Bt aap check Kare kuch hi appliances me bahut hi km na ke barabar wo kaam karata h......
Very useful video 👍👍👍
So nice of you
Mere hesaab we tho koi fark nahi padhega aur ulta yeh bhi power consume karega
Aap tho kuch
Sir you add resistance between two wire of capacitor that's why it's not work. Second if power factor already equal to 1 than it can't be improve it's optimum value .
Eye-opener video, there are numerous videos which fools the common people, thanks for your work.
Good one ... But plz mention watch complete video in title
👍👍👍
Ya power saver nahi he ya apka bill kam nahi krega zyada karega
sahi kaha
Many of the similar videos increases the electricity bill. This can improve the power factor. But there should be a reactive load. Otherwise it will increase the bill.
Q
Kesy
Umer but phir kesy km hoga?
Thankyou very much sir you reveals the reality of this. ❤
Hello sir aap ka video Dekhkar mujhe bahut accha laga jitne company power saver banate hain Sabhi company public co chutiya banati hai Toh Phir sir Aisa Koi power save Aap Hume bataiye Aisa Koi power save hai kya Jo Bijli bill kam kar sake thank you sir bahut bahut dhanyavad
Thanks you Bhai bahot a cha explain Kiya
Pls change the title... I guess u wanted to expose the scam
So the title should be
POWER SAVER DEVICE SCAM EXPOSED
आपने बिल्कुल सही जानकारी दी है ध्यान रखूंगा
Capacitors can't save energy.
bahut achcha samjhaya
Kese karega na he amp drop ho rha hai or na he voltage
Very best information thanks for you
Please change title to "power saver scam exposed with proof"
Good job to give the correct information
Can you explain how a capacitor can save energy??? 😂😂😂 hahahah!!!!!!
very good information sir ji
Abhe "extra power consumer" title bana...
Waste of time with fake knowledge
Very good information thanks bro
Superb... Here cap never save any power.. reactive power only impro. but active power remain same. Also add cap as a load...
Is the current consumption will be decrease?
@@lifeishard1875 No it does nothing
Very nice information👍
Thank you
Thanks a lot, aapke videos mujhko shuru se he bahut pasand hai. Aap ne bilkul sach kaha capacitors lagane se kuch nahi hoga. Sir aap he koi power saver device bana ker dijiye. Waise bhi india mein parallel mein connect hone wale capacitors nahi milte, agar iss tarah se connect karege to capacitor burst ho jayaga overcharge ki wajah se.
Because adding cap bank wil only decrease VARs, not kW. Billing is done on kW, if it was done on kVA only then cap bank wud have decreased electricity bills.
This is not power saver , it is a starting capacitor used at fan or motor and it's rating is in micro farad or MFD.
If u use Power capacitor with KVAR rating according to your house current load then u will get result.
Aap ne thek kaha cap ki value sahe ho gi to amp kam ho jae ge thanks
Insted of demanding reactive power,. Generate reactive power send back to source. Can be done to certain extent.
Tune sari mehnat karne se bacha liya bhai. Thanks.
भाईसाब आप लोगों का आंख खोलते है बहुत बहुत बढीया ऐसा ही आप व्हिडिओ बनाते रही है ऐसे लोगोन से बचने के लिए
I think only watchfullness conciousness and proper use of applances and equipments can help reduce electric power consumption. 😊plus a knowledge of electrical formulas like ohms law etc .
Good job sirji
Good advice lot of thanks for power sewer device hota hai ..?
Good informative ! What that device you using to measure the watts with multiple switches it's having ? Please give the name of the meter & available link.
your investigation is exactly correct the device nothing will do. Well done bro
Very good, it's clear so Google most delete all the wrong information:-)