Control Your Air Handler Fan Speed Like a Pro! @YorkHomeComfort

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ส.ค. 2024
  • Duct Design and Airflow hvac basics video
    • Duct Design and Airflo...
    Anemometer HVAC Tool Basics (CFM, FPM and Capacity)
    • Anemometer HVAC Tool B...
    My house has high humidity. How do I fix it video
    • My House has High Humi...
    Tools I use
    Fieldpiece SRH3 In-Duct Digital Psychrometer
    amzn.to/3AijeYM
    Testo Digital Pocket Vane Anemometer
    amzn.to/3KtMcda
    Join this channel to get access to perks:
    / @taddydigest
    Wanna learn more about hvac? Check out my hvac tips for technicians playlist.
    • HVAC Tips for Technicians

ความคิดเห็น • 55

  • @rj.parker
    @rj.parker ปีที่แล้ว +2

    York has always had good electronics with well thought out algorithms. Indoor and defrost boards. There is also a method via a dehum input to the indoor board which allows the thermostat control of a reduction in airspeed even when the Delay timers have expired. When these options are combined with a two stage scroll, very good dehum and low interior sound levels are the norm. I like York/Johnson Controls has started protecting the board with an enclosure. Finally, it should be obvious that hacking in a psc replacement just because the ecm motor module has failed, severely impacts the customer's comfort and noise levels. I sometimes offer a customer the option of keeping spare modules at reduced, close to wholesale cost. Its a win win that makes you a hero if they need one in a hurry.

  • @dalechurch4954
    @dalechurch4954 9 หลายเดือนก่อน +1

    Great video thanks for sharing it I had my txv values changed and then my blower motor went out it would blow high and low I had it replaced and now it blows a little different high then very low and the temperature is different by 3 or more dregs and feels more cool and not warm set on 79 but in front room is 75. It is a heat pump in a mobile home single wide. It was warming and cooling before they changed the motor. Thanks have a blessed day 🙏

  • @josuevargasvargas9126
    @josuevargasvargas9126 ปีที่แล้ว +3

    Buenas noches amigo soy de Guatemala estoy en un curso de climatisasion y tus videos son increíbles gracias por compartir tu conocimiento

  • @GodManDeez
    @GodManDeez 3 หลายเดือนก่อน +1

    love how you broke this down in the simplest way possible deff got a subscribe from me

    • @TaddyDigest
      @TaddyDigest  3 หลายเดือนก่อน

      Excellent news brother. Thank you so much for watching

  • @paulrozinski1488
    @paulrozinski1488 ปีที่แล้ว +1

    What, you mean I actually have to read the instructions ??? I don’t have time for that ! I’ve got 19 other jobs I have to get to today…….
    It’s a pity that this is what the service industry has become.
    In NYC, there used to be a men’s clothing store called Sym’s and there motto was: “ An educated consumer is our best customer”.
    Perhaps some of that holds true in the HVAC world. Maybe the homeowner should pick up the book, read it then ask the tech how he set up their unit and why. Hopefully , the tech won’t respond “ it’s cooling ain’t it ?”.
    Great video, learned a lot. My next unit will definitely be a variable speed . Keep ‘em coming.
    Paul ……….. NYC

  • @user-yx6py3hs2q
    @user-yx6py3hs2q 6 หลายเดือนก่อน +1

    Very nice video and well explained. Thanks for your patience in explaining to us.

  • @danwake4431
    @danwake4431 ปีที่แล้ว +1

    i have a Lennox SLP98UHV unit with single stage 2.5ton unit outside.
    My communicating thermostat died and the replacements are $800 and don't last long either. So I went in the basement and put the unit in non-communicating mode so I could use an Ecobee thermostat.
    The house is comfortable but I feel like I need to dial in the fan speed in better. The way it is now, when cooling it will run at 900cfm for about 6 minutes then ramp up to 1100 for a minute then shut off. I don't have fancy measuring tools so I just used a laser temp gun. Im sure it's not 100% accurate. The day I took temps it was 92 outside, thermostat set for 71. When it hit 73 inside the unit kicked on. The air coming from the register was 48F. I keep the 5" filter replaced every 6 months (not 12 months like it recommends) and the unit cools very well.
    Should I change to a different fan speed setup? Google says fans should run for 15-20 minutes to keep from wearing out the compressor and other reasons. And you mention the vents being too noisy but even at 900 I can hear it if the tv is off. And 1100 cfm is loud obviously. Should i slow it down even more to make it run longer?

  • @MartinLDeLoach903
    @MartinLDeLoach903 ปีที่แล้ว +2

    The sad part of the extreme humidity in North Tx, 80-90% for last few months, and now getting hot, the humidity kills your condensor fan motor.

  • @MartinLDeLoach903
    @MartinLDeLoach903 ปีที่แล้ว +2

    I live in in North Texas and sure has been more humid than normal staying at 80 to 90% for awhile from all the weeks of rain.

  • @pa2467
    @pa2467 11 หลายเดือนก่อน +1

    Thank you! I think my unit needs an adjustment like this one. It is too loud right now lol

  • @carmenspina7967
    @carmenspina7967 6 หลายเดือนก่อน +2

    Thanks for sharing

    • @TaddyDigest
      @TaddyDigest  6 หลายเดือนก่อน +1

      your welcome

  • @texas_triple8146
    @texas_triple8146 7 หลายเดือนก่อน +1

    Thank you
    San Antonio Texas

    • @TaddyDigest
      @TaddyDigest  7 หลายเดือนก่อน

      You're welcome

  • @DougDavis
    @DougDavis หลายเดือนก่อน

    I’m having the hardest time following your tutorials because my system looks so different.
    I have options for speeds from
    Lo cool, heat, hi cool and G?
    And delays are
    60-180 (4 options)

  • @HVAC-TECH-Les
    @HVAC-TECH-Les ปีที่แล้ว +2

    Hi Tad, if I understood you and the procedure in the beginning, I believe you said the motor will compensate for high static pressure. What was the static pressure of this unit? Was the blower compensating for high static when you had the higher CFM's and noise in the beginning?Thanks for the great video!

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +1

      I do not know what the static. I did not have my Tool for that at the time
      I will do a video soon with the magnehelic

  • @rickbarber6758
    @rickbarber6758 10 หลายเดือนก่อน +3

    If that's a two story house the upstairs will be hotter with less push.

  • @DianaPixieDust
    @DianaPixieDust ปีที่แล้ว +1

    Hi and THANK you for the info! I live in South Florida, talk about heat and humidity! It’s July been 100 everyday outside and rain. I got a brand new Goodman HVAC central air system in my condo. The technician recommended lowering the blower (I don’t know what level he set it, this is not my field) and said it will run quieter and rid the rooms of humidity. It is working great. My indoor thermostat is reading 35% humidity. That’s DRY for us. *It gives me a sore throat during the night it’s pretty dry, but I’d hate to raise the blower because it’s so efficient. Do you think lowering the blower also saves on the electric bill? I’ve noticed it’s about the same as it always was. It does feel a lot better inside though.👍

    • @surgicaltoolboxrnhealthbea3292
      @surgicaltoolboxrnhealthbea3292 8 หลายเดือนก่อน

      I need to get the blower set lower in n. Rheem 2.5 ton. It’s so loud and doesn’t kick on as often. The breeze is way too strong. I need to hire someone. So the humidity isn’t as dry as I like. Can I lower this or have to buy a device. I’m in southeast Florida.

  • @TonyRodriguez-ok2ix
    @TonyRodriguez-ok2ix หลายเดือนก่อน +2

    dehumidification is closely related to fan speed

  • @jamestoy426
    @jamestoy426 ปีที่แล้ว +3

    If you had to put in a psc motor what tap would you use? Would be. Interesting to see a manometer hooked up to see static. James Toy Mesa,Az

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +1

      If you had a psc motor you wouldn't be using the board or the taps
      That's a good idea using the magnehelic during the process I will do that next time

  • @jamesf8783
    @jamesf8783 11 หลายเดือนก่อน +1

    Thank you for this i was able to slow the blower on cool from high to med lo and it made a big difference in how well my ac works! Do you think i should try putting it on low? I don't have a york but man what a difference!

    • @TaddyDigest
      @TaddyDigest  11 หลายเดือนก่อน +1

      Great to hear!

    • @jamesf8783
      @jamesf8783 11 หลายเดือนก่อน

      @@TaddyDigest do you think i should try it on low?

  • @MartinLDeLoach903
    @MartinLDeLoach903 ปีที่แล้ว +1

    Its worse if you go south Tx where you are right off the Gulf, that sea water in the air will rust out your air system in no time.

  • @alexorta1930
    @alexorta1930 หลายเดือนก่อน

    Hey, I was just wondering if you can suggest a good HVAC technician in central Florida thank you so much.

  • @o.k.johnson6218
    @o.k.johnson6218 ปีที่แล้ว +1

    I have a York TM9V 60,000 BTU furnace. I want to adjust the fan speed, but I can't find what size of jumper to use and where to get them. This is just for cooling mode. Pushes a lot of air. I want to dial it back just a bit so it runs a little longer with better dehumidification.

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      Send me an email tadfuller1@gmail.com

  • @Zcamm
    @Zcamm 9 หลายเดือนก่อน +1

    Hey man… I have a question… trying to call my HVAC guy but no answer, maybe he died or something.
    I have a Bosch 2.0 IDS 3 ton condenser with a variable speed carrier air handler, but I only notice one speed , very fast coming out the vents… and it turns on and off a whole lot. What do I have to do to make it slow down the speed so it doesn’t have to turn on and off so damn much.
    Thanks buddy!

    • @TaddyDigest
      @TaddyDigest  9 หลายเดือนก่อน

      I'm not sure
      I have never worked on that model of equipment

    • @Zcamm
      @Zcamm 9 หลายเดือนก่อน +1

      @@TaddyDigest son of a b…..
      You should come to my house and work on it so you’ll be more versed in all this hvac stuff, LOL

  • @nyculc
    @nyculc ปีที่แล้ว +1

    Will doing the steps you show have any effect on the Heat blower speed? I have a york gas pack and from what I understand the blower speed would need to remain higher for that.

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +1

      there are speed taps for heat and cool on this unit so I only adjusted for the cooling

    • @nyculc
      @nyculc ปีที่แล้ว +1

      @@TaddyDigest thanks. My York unit looks very similar and I was afraid to try any changes before having a better understanding of the setup. Thanks for the video. Very helpful! :)

  • @RamiTest
    @RamiTest 6 หลายเดือนก่อน +1

    what is the difference between Cool/Heat taps and Adjust ?

    • @TaddyDigest
      @TaddyDigest  6 หลายเดือนก่อน

      Cool is adjusting the fan speed in cooling
      Heat is adjusting the fan speed and heating
      And adjust gives you an option to increase or decrease fan speed a certain percentage.

  • @Jojojojo1
    @Jojojojo1 ปีที่แล้ว +1

    Do I need to be concerned at lower speeds of the coils freezing? I had a tech here just today who would not put the speed lower than what he did because he said the coils will freeze. I live in central Florida swamp, so it is about to get very humid and I want to add the delay and reduce the speed to better manage humidity so I don’t have to have a portable Dehumidifier in the house.

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      You can monitor the suction pressure and temperature while adjusting air flow
      Unless the technician saw a low suction pressure I think he was probably making that up

  • @scottallen5182
    @scottallen5182 ปีที่แล้ว +1

    Were you able to maintain a proper superheat with the lower air flow?

    • @rj.parker
      @rj.parker ปีที่แล้ว

      Generally the txvs will maintain superheat over a wide range. Often these ecm systems are also 2 stage allowing first stage operation as well. Assuming a proper thermostat is used, typically a better Honeywell.

  • @stevo6891
    @stevo6891 ปีที่แล้ว +2

    Do you do Commercial HVAC?

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +2

      yes

    • @stevo6891
      @stevo6891 ปีที่แล้ว +2

      @@TaddyDigest Did you go to a trade school? If you did they let you work on commercial units in class?

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +2

      I did go to trade school
      we did get to work on commercial units maybe a couple times

    • @stevo6891
      @stevo6891 ปีที่แล้ว +2

      @@TaddyDigest I’m going to a hvac school very little they go over commercial mostly residential.. Wonder how you get commercial experience though?

    • @cashonlyj3469
      @cashonlyj3469 ปีที่แล้ว +1

      I seen a palm tree behind you.They must have started to invade Tennessee. Watching from Paris

  • @davidcook4773
    @davidcook4773 ปีที่แล้ว +1

    Do you know how I would find the heater kit model that is installed? We have this same 48C model but the installers did not mark what heater kit it has on it

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว +1

      It's up inside the cabinet on the bottom piece of metal

    • @davidcook4773
      @davidcook4773 ปีที่แล้ว

      This is fantastic, thank you! Looks like I don’t have one since I’m in south Texas, but this has been really helpful

  • @Almtyhalfbreed
    @Almtyhalfbreed ปีที่แล้ว +1

    So the installer set it to wrong speed?

    • @TaddyDigest
      @TaddyDigest  ปีที่แล้ว

      The installers that we have usually never set them up because they don't know how

  • @tigerz4487
    @tigerz4487 2 หลายเดือนก่อน +1

    ding