Reation - End point Reation - kinetic Reaction - Fixed time kinetic All reaction ka parameters Machine per program ready karne ke time Kon sa Kon sa mode keya select korna hei?
Value of bilirubin is directly proportional to the factor we input manually...Not with the standard concentration... In the bilirubin reagent standard not supplied..
Nice video.. Please I need a programming for Total and Bilirubin using vitro scient reagent
Very informative video...
End point me konsa mode, kinetic point me konsa mode, fixtime kinetic me Kon sa mode selecte korna hei?
End point-- 1 point
Kinetic-- Rate A
Fixtime kinetic-- 2 points
Thank you sir... For this video...
Reation - End point
Reation - kinetic
Reaction - Fixed time kinetic
All reaction ka parameters Machine per program ready karne ke time Kon sa Kon sa mode keya select korna hei?
End point--- 1 point
Kinatic-- Rate A
Fixed time kinetic-- 2 point
Please give vedio about t3,t4 and tsh.
Sir ye machine kaiser had for lipid profole
Thank u very much sir video achi h. Sir ek video pt aptt Menueval kar ke dikha do please
Kya issme crp quntittative lagta hau
Chem 7 machine mein filter 600,670 error dekha raha he... kaise resolve kare
Plz edit normal range. By mistake u enter 102 instead of 1.2
Ye campany ka bio chem machine lene ka kya proses rheta hai sir plese batye mujhe
Aap company ke web site me ja ke.. mail kijiye.. or sales executive se contac kijia...
u can also share the method in descripition below the video
Sir standard aspirate kyu nahi karna partaa hai
Sgpt aur sgot par bhi programing set karne ka video banaiye sir
Ok
Sir print sound off kaise kare
which one is enough for small lab chem 5x or chem V2? maximum patients per day 5-8
Both r better but I suggest chem 5X
Sir erba ka kon sa model khride
Chem 5 & chem 7 both r best...
Chem7
Plz put vdo about tsh.plz sir.
Ok. Coming soon..
Sir RA factor ka programing ko btaiye n
Ok..Comming soon
Sir please s.calcium ke perameter ke baare btaye
Sir crp lagata hai iss erba chem 5
Yes
Crp ki video bana de erba chem 5 pe
Bro back Ravali Glv mudhu undhe thye raledhu
English plz...
Kindly give me tips
Wash the cuvette property or change it..
Sir or bi test kro
Bro mathomu maripoyedhi
Sir humko lagta h ki aap english se acha hindi me hi bole to acha hoga ...
This is wrong there is std. Concentration is 0 we have to set
if we set 10 value of bilirubin is increases automatically
Value of bilirubin is directly proportional to the factor we input manually...Not with the standard concentration... In the bilirubin reagent standard not supplied..
Sir video sahi se banaiye kuch bhi theek se dikha nahi please please sir video dobara sahi se banaiye please
bhai pehle vedio bnana sikh le fir aana youtube pr
Thank you for your great suggestion...
Humko biochemistry ki machine lena hai kitni Kiya jayegi
Biochemistry ki machine humko Lena jaanch karne ke liye humko live dalna hai kitne Tak aa jayegi machine