Walk in freezer gets warm

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 พ.ย. 2024

ความคิดเห็น • 22

  • @Ted_E_Bear
    @Ted_E_Bear ปีที่แล้ว +2

    Thanks Joe for letting me go to work with you ! I really appreciate and enjoy your videos !

  • @timfiggins7764
    @timfiggins7764 ปีที่แล้ว +1

    New feature, banana panels 😅. Glad you posting content again. Keep it coming

  • @HVACRNorth
    @HVACRNorth ปีที่แล้ว +1

    Good Job Joe ....love how Joe is everywhere thanks ....

  • @Farm_fab
    @Farm_fab ปีที่แล้ว +1

    Joe, that roof area with the water damage reminds me of a job we were on years ago. I worked for a contractor that did mechanical demolition, and I stepped onto a roof curb that once had either a skylight or an HVAC unit. They covered the opening with waste-of-wood , er, I mean wafer wood, and one of my legs went through, but my point is that whoever was there before we got on site didn't think things through.
    This building was once used by a defense contractor, but it's not likely they did any roof work as the building had been vacant for some time. It was being remodeled for part of an expansion of an online distributor.
    To boil things down, wafer wood should not be used for covering roof openings.

  • @kurtweck2276
    @kurtweck2276 ปีที่แล้ว

    Thinking door was left open for morning food prep. Usually where snow comes from,not ice.

  • @liam3284
    @liam3284 ปีที่แล้ว

    Something in the box was making a loud high pitched sound. Thought it was refrigerant at first.

  • @stephenhunter70
    @stephenhunter70 ปีที่แล้ว

    What I noticed with the timer was it was sitting at about 4 am in the morning your local time. And the water draining off the roof, is bypassing the roof drain due to the condition of the roof. And the distributor or TXV!

  • @fshn76
    @fshn76 ปีที่แล้ว

    Great video Bill. Very good possibility that air leakage from those warped panels could definitely be causing the issue. “Big Picture” right. Chris needs to get shirts made with that on there. 😅

    • @MegaDysart
      @MegaDysart ปีที่แล้ว +1

      i think he does have a big picture shirt haha

  • @dmiestercommkitchentech3043
    @dmiestercommkitchentech3043 ปีที่แล้ว

    Also possibly a restricted external equalization tube not a low charge could be air infiltration only pressures could verify what the cause is

  • @johnwalker890
    @johnwalker890 ปีที่แล้ว

    Good job.

  • @danpresson
    @danpresson ปีที่แล้ว

    Awesome video is that a new wireless manifold how

  • @veil67
    @veil67 ปีที่แล้ว

    poor
    condition of the box and a
    good posibility of the door left open for a long period

  • @dmiestercommkitchentech3043
    @dmiestercommkitchentech3043 ปีที่แล้ว

    My first suspect would restricted distributor not undercharge expansion valve body would be incased with ice due to refrigerant flashing inside the Txv body not at the entrance of the distributor tube.

    • @keepright5232
      @keepright5232 ปีที่แล้ว

      Why would you say so?

    • @dmiestercommkitchentech3043
      @dmiestercommkitchentech3043 ปีที่แล้ว

      @@keepright5232 because refrigerant flashes off at the inlet of the distributor and is 75% vapor most undercharges will cause the expansion valve to become incase in ice because the lower amount of refrigerant causes the TXV valve body to be extremely cold which causes it to freeze up the valve body the freeze line was after the distributor instead of at the TXV so low charge was possible but not the most likely issue.

  • @Jeff-Lawrence
    @Jeff-Lawrence ปีที่แล้ว

    So you’re thinking the ice was from too much moisture getting in the freezer?

  • @harrydickson4575
    @harrydickson4575 ปีที่แล้ว

    👍👍👍

  • @bonniemaxwell4402
    @bonniemaxwell4402 ปีที่แล้ว

    ❤😊

  • @steveblake8766
    @steveblake8766 ปีที่แล้ว

    144 thumbs up

  • @specialK_hvac
    @specialK_hvac ปีที่แล้ว

    First! 🎉🎉🎉

  • @natepeterson7145
    @natepeterson7145 ปีที่แล้ว

    Not 1st