3 Level Neutral Point Clamped Grid Connected Inverter | MATLAB Simulation

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ธ.ค. 2024
  • In this video, i am demonstrating the simulation of 3 level NPC grid connected inverter using matlab. If you have any doubts regarding the simulation, feel free to post it in the comment section.
    If you like my work, please consider subscribing to this channel. Thanks for watching.

ความคิดเห็น • 76

  • @TechSimulator
    @TechSimulator  4 ปีที่แล้ว +4

    If you like my work, please do consider subscribing to this channel.Thank you. th-cam.com/channels/58DFky5Fm9AxH9UmWHHYmQ.html

    • @griffithdidnothingwrong3776
      @griffithdidnothingwrong3776 ปีที่แล้ว

      Does the NPC inverter works with the control design you used for 3 phase standalone inverter for balanced and unbalanced load?
      Also will you consider making a video on inverter switching design from grid tie to islanding?

    • @mingyang465
      @mingyang465 10 หลายเดือนก่อน

      hi there would i be possible for u to share the stimulation file?

  • @himanshumaithani8499
    @himanshumaithani8499 4 ปีที่แล้ว

    thank you so much Sir for making videos which are really very helpful and conceptual and also brings us the MATLAB as a interesting software

  • @subirdatta6930
    @subirdatta6930 2 หลายเดือนก่อน

    This is very informative & knowledgeable video.
    But, I a doubt on PWM. You considered one carrier is (0 1 0) & other one is (-1 0 -1). It will be very helpful if you share the concept of it with us.
    Thank you.

  • @suprajarajkumar223
    @suprajarajkumar223 ปีที่แล้ว +2

    kindly, explain how to calculate the filter values (L&C). You directly put the values so we cann't able to design the inverter for some other ratings. Pls explain the parameter design too. It will be helpful for us.

  • @s.p.biswas6462
    @s.p.biswas6462 4 ปีที่แล้ว +1

    Thanks for the video. Very good explanation. Can you please make some videos on Multilevel inverter fed induction motor drive? For example., 5 Level NPC inverter, Cascaded H-Bridge inverter fed Induction motor using vector control or direct torque control. I highly appreciate your work. I have also recommended my students to follow your channel for better understanding of inverter control. Thanks in advance. Go ahead.

  • @muhammadarmghanmehmood6746
    @muhammadarmghanmehmood6746 3 ปีที่แล้ว +1

    Can you please also do the 1 stage grid connected NPC inverter. I'm having issues in designing the outer voltage control loop design following the design you mentioned for the 2 level solar inverter. Thankyou

  • @nedimkazic5555
    @nedimkazic5555 4 ปีที่แล้ว +2

    Thanks for the videos man
    I was curious, thought it is a bit outside of what you're doing, how to design a PV +Battery off grid system
    Cheers

    • @TechSimulator
      @TechSimulator  4 ปีที่แล้ว +1

      I am preparing videos on PV inverter grid battery etc. will upload very soon

  • @mohanraj411
    @mohanraj411 ปีที่แล้ว

    Hi, can you explain the differences and uses of 3 level over 2 level in detail ?

  • @ebarbie5016
    @ebarbie5016 3 ปีที่แล้ว +5

    This will not work OK for a practical system with unbalanced grid/load because you neglected to apply voltage balancing to the inverter DC bus. You should feed the Vc1-Vc2 error to a third PI controller and feed the output to the zero vector port of the final dq0 to abc transform...

    • @kamadjesadjiedjienaallen9259
      @kamadjesadjiedjienaallen9259 15 วันที่ผ่านมา

      are you trying to say he should apply VOC control scheme to balance the voltage at the inverter DC bus?

    • @ebarbie5016
      @ebarbie5016 15 วันที่ผ่านมา +1

      @@kamadjesadjiedjienaallen9259
      yes. DC bus balance can be achieved by modulating a dc current component into the dc junction as in a Vienna rectifier.

  • @jyothiradityar6455
    @jyothiradityar6455 4 ปีที่แล้ว +2

    Can you also do droop control?

  • @royaltyfreemusic2633
    @royaltyfreemusic2633 3 ปีที่แล้ว

    Can you use p.u values for the controller ?? if so can you explain how it can be done!

  • @vasavisai1890
    @vasavisai1890 3 ปีที่แล้ว

    Instead of diode can i use igbt? And this application will be ANPC Inverter

  • @divyanshubharti8714
    @divyanshubharti8714 ปีที่แล้ว

    Sir i have made 3 level npc but i am getting 9 level output out of inverter.

  • @anuj6386
    @anuj6386 7 หลายเดือนก่อน

    why did you set -205 as reference/

  • @muhammadarmghanmehmood6746
    @muhammadarmghanmehmood6746 4 ปีที่แล้ว +3

    I've emailed you but there was no reply. Can you please make a video or refer to some literature about how to calculate PI controller parameters. That'll be very helpful. Thanks

    • @vasavisai1890
      @vasavisai1890 3 ปีที่แล้ว

      I am also looking for it

    • @muhammadarmghanmehmood6746
      @muhammadarmghanmehmood6746 3 ปีที่แล้ว +1

      @@vasavisai1890 This book can help in this regard.
      www.scribd.com/read/370032519/Control-of-Power-Electronic-Converters-and-Systems-Volume-1?mode=standard#

    • @vasavisai1890
      @vasavisai1890 3 ปีที่แล้ว

      Thank you for sharing it

    • @vasavisai1890
      @vasavisai1890 3 ปีที่แล้ว

      Do you have any tutorial for ANPC inverter?

    • @muhammadarmghanmehmood6746
      @muhammadarmghanmehmood6746 3 ปีที่แล้ว +1

      @@vasavisai1890 unfortunately not. I'm combining the knowledge of this book and tutorials of this channel

  • @anilkumartiwari5165
    @anilkumartiwari5165 2 ปีที่แล้ว

    Sir how to model dc-link as a current source ,also how to find value of C for dc link?

  • @ravalikotha3906
    @ravalikotha3906 4 ปีที่แล้ว

    Sir please also show how to find THD for this 3 level NPC grid connected inverter

  • @ZenoIG
    @ZenoIG 2 ปีที่แล้ว

    brother can you make this converter bidirectional for EV charging?

  • @saudurrehman1104
    @saudurrehman1104 2 ปีที่แล้ว

    Can you please make a video on Dynamic Voltage Restorer using Cascaded H bridge 7 Level Inverter for Voltae Sag Mitigation.

  • @owaisuddin7394
    @owaisuddin7394 2 ปีที่แล้ว

    Sir what about grid current and inverter current comparison???

  • @عبداللهطهراوي-و9ق
    @عبداللهطهراوي-و9ق 3 ปีที่แล้ว

    What did he do in 05:32

  • @tallapakaabhishek9181
    @tallapakaabhishek9181 4 ปีที่แล้ว +1

    Reason present behind '2/800 'gain block.
    pls......thnks in advance

    • @vasavisai1890
      @vasavisai1890 3 ปีที่แล้ว

      I am interested to know about it. Please comment the reason.

    • @royaltyfreemusic2633
      @royaltyfreemusic2633 3 ปีที่แล้ว

      @@vasavisai1890 It stems from the modulation index (duty cycle) or simply it's the relationship between between Vdc and Vinverter

  • @ADGGMB
    @ADGGMB 3 ปีที่แล้ว

    It could be use as ACDC rectifier?? If yes, how does the control change? Excelent video

    • @ebarbie5016
      @ebarbie5016 3 ปีที่แล้ว +1

      Look for the Vienna rectifier, which is a three-level AC to DC converter. Control is different.

  • @arminhasanzadeh5161
    @arminhasanzadeh5161 3 ปีที่แล้ว

    Is this design is Space Vector PWM (SVPWM)?

  • @alial-khayyat8934
    @alial-khayyat8934 4 ปีที่แล้ว

    Thanks for your effort. Please can you provide where is the equation of the control come from? I mean
    Vd + Ed + wL×iq
    How can we get it ?

    • @TechSimulator
      @TechSimulator  4 ปีที่แล้ว

      This is the basic kvl equation. Grid voltage is equal to sum of inverter voltage and voltage drop across the filter inductor.

  • @ahmednaji635
    @ahmednaji635 4 ปีที่แล้ว

    Thanks for your efforts man ... what about the capacitor control and can we doing variable reference?

    • @TechSimulator
      @TechSimulator  4 ปีที่แล้ว +1

      Sorry brother. I didnt get your question?

    • @ahmednaji635
      @ahmednaji635 4 ปีที่แล้ว

      Bro i mean if the source is varied dc input how can i got the reference current the second how can i make capacitor balance control

    • @vasavisai1890
      @vasavisai1890 3 ปีที่แล้ว

      @@ahmednaji635 same doubt, how tl select the dc link capacitors?

  • @ravalikotha3906
    @ravalikotha3906 4 ปีที่แล้ว

    sir in this why we are fixing current to -205 sir

  • @jorgeosorio9367
    @jorgeosorio9367 4 ปีที่แล้ว

    Gracias por el aporte excelente

  • @vasavisai1890
    @vasavisai1890 3 ปีที่แล้ว

    I designed this simulation and verified it three times. I found everything is fine according to this video but the output current has oscillations.
    I found three-level voltages at inverter output have to peak voltage ripples. How to solve it..... Please help me... Thanks in advance

    • @mouhamedyou
      @mouhamedyou 3 ปีที่แล้ว +1

      did you solv it ? i have the same probleme

    • @vasavisai1890
      @vasavisai1890 3 ปีที่แล้ว

      @@mouhamedyou No man

  • @mingyang465
    @mingyang465 ปีที่แล้ว

    What about for a single phase?

    • @TechSimulator
      @TechSimulator  10 หลายเดือนก่อน

      ??

    • @mingyang465
      @mingyang465 10 หลายเดือนก่อน

      @@TechSimulator Model Predictive Control for Single-Phase Active Neutral Point Clamped Converter

  • @ARVINDKUMAR-jp4lm
    @ARVINDKUMAR-jp4lm 4 ปีที่แล้ว

    please if possible make parallel inverter connected to grid with droop control

  • @vasavisai1890
    @vasavisai1890 3 ปีที่แล้ว

    How to calculate the dc capacitor values?

    • @ebarbie5016
      @ebarbie5016 3 ปีที่แล้ว +2

      He used very large capacitors with ideal DC source and balanced grid, which is why the control worked despite the fact that he forgot to apply capacitor voltage balancing control... TH-cam is not a good place to learn electrical engineering...

    • @vasavisai1890
      @vasavisai1890 3 ปีที่แล้ว

      @@ebarbie5016 could you please suggest me the best platform to learn
      Thank you

  • @mustaphabm3394
    @mustaphabm3394 3 ปีที่แล้ว

    thank you very much it was really helpful.
    i will appreciate if you can help me with the simulation of 5 level modular multilevel converter grid connected.

  • @skmachines1356
    @skmachines1356 8 หลายเดือนก่อน

    Link

  • @jerryli8105
    @jerryli8105 8 หลายเดือนก่อน

    still exsited black box

  • @ravalikotha3906
    @ravalikotha3906 4 ปีที่แล้ว

    Sir I have sent a mail to you please see where i have done the error it is important sir

  • @ravalikotha3906
    @ravalikotha3906 4 ปีที่แล้ว

    Sir I have sent you a mail please check it once I am getting error in 3 level please check it once

  • @razanallaham3518
    @razanallaham3518 4 ปีที่แล้ว

    I send you a message in your gmail > please find attaced . thank you very much.

    • @73mmujtabaakram14
      @73mmujtabaakram14 ปีที่แล้ว

      Please send me the Gmail of ​tech simulator

  • @slavak7729
    @slavak7729 7 หลายเดือนก่อน +1

    Activate Windows, dear pirate