Rules for Lapping in RCC Columns

แชร์
ฝัง
  • เผยแพร่เมื่อ 28 ส.ค. 2024
  • This video shows some basic rules for lapping the steel bars in RCC Columns. Some of these rules are;
    1. The diameter of overlapping steel bars should not exceed 36 mm.
    2. Always use smaller diameter of bar while calculating the overlapping length in case of columns.
    3. Lapping is only allowed in the compression zone of column where there is no bending moment.
    4. The tilt length of steel bars in overlapping can be calculated by using this equation, 6D. Where D is the diameter of the steel bar.
    For more rules please watch full video.
    Our channel brings civil engineering videos for students of Diploma, B-tech, M-tech, Bachelors and Masters.
    Subscribe our channel for more civil engineering videos.
    / civilengineeringonlyci...
    #Rules_for_Lapping_in_RCC_Columns
    lapping length
    lapping zone
    RCC column
    bending in columns
    Lapping regions in column

ความคิดเห็น • 38

  • @saikathatiallrounder6183
    @saikathatiallrounder6183 4 ปีที่แล้ว +1

    Thanks sir.. You are best sir.. Your all knowledgeable video is fantastic.. Keep on..

  • @Pherramoo
    @Pherramoo 2 ปีที่แล้ว

    I feel smarter. Great video

  • @bakhtullahyoun931
    @bakhtullahyoun931 4 ปีที่แล้ว

    Helpful info sir
    Love from Afghanistan

  • @anantjangam04
    @anantjangam04 3 ปีที่แล้ว +1

    Sir, good explanation, but I have a question that, we calculate lapping length by higher dia of bar ( our sr.said it) and coupler can be use to 36 dia of bar instead of wedding

  • @vijaynayak-cb6ie
    @vijaynayak-cb6ie ปีที่แล้ว +1

    As per IS 456 -2000 3rd Amendment 2007 Lapping is not provide Diameter greater than 32mm

  • @amitcds
    @amitcds 4 ปีที่แล้ว +2

    In existing 3rd floor, how to convert or extend the 4 by 4 column into 9 by 9. hereafter ...does it give strength to take extra 4th floor in the building where below two floors have 9 by 9 column.

  • @amitwalde2064
    @amitwalde2064 3 ปีที่แล้ว

    Thank you so much for helpful information

  • @PatrickInCayman
    @PatrickInCayman 3 ปีที่แล้ว

    Very clear explanation, thank you! What should be the angle of the bend of the 72 mm example?

  • @shamchavan8425
    @shamchavan8425 3 ปีที่แล้ว

    Nice information sharing Thanks sir 🙏

  • @a1teluguconstruction245
    @a1teluguconstruction245 3 ปีที่แล้ว

    Sir why should not provided at other than center of the column

  • @zannatulaklima8825
    @zannatulaklima8825 3 ปีที่แล้ว

    amazing explanation sir. Thanks.

  • @manojkumar-qu8ml
    @manojkumar-qu8ml 3 ปีที่แล้ว

    Welding of column lapping for 4*12 mm is good or not for 2 ft distance ( all four bar in same distance) only available above slab for 1st floor only house. Does welding reduce its strength. If ok, how much length does it need to welding

  • @ramazanpayman5025
    @ramazanpayman5025 4 ปีที่แล้ว

    Great explain, thank u so much.

  • @parthasarathisumandutta6530
    @parthasarathisumandutta6530 3 ปีที่แล้ว

    What is the name of the slightly Angel portion in the lapping is it Doc pin or dropting

  • @lonesurvivor6475
    @lonesurvivor6475 3 ปีที่แล้ว +1

    good work

  • @taihtasu
    @taihtasu 4 ปีที่แล้ว

    Sir.. which standard guidelines you use?

  • @CricCreation
    @CricCreation 4 ปีที่แล้ว

    Thank You so much ❤️

  • @sashankuprety1706
    @sashankuprety1706 3 ปีที่แล้ว

    Which code are these provided on???

  • @shabeebali9742
    @shabeebali9742 3 ปีที่แล้ว

    Very good

  • @a1teluguconstruction245
    @a1teluguconstruction245 3 ปีที่แล้ว

    Nice sir

  • @asfandyar134
    @asfandyar134 2 ปีที่แล้ว

    Hai koi Allah ka Banda jo Bata sakay keh yeh 24D 40D 50D kahan say Ata Hai.. Aur isay kesay derive Kar saktay hain.

  • @vijaynayak-cb6ie
    @vijaynayak-cb6ie ปีที่แล้ว +1

    As per IS 456 -2000 3rd Amendment 2007 Lapping is not provide Diameter greater than 32mm

  • @a1teluguconstruction245
    @a1teluguconstruction245 3 ปีที่แล้ว

    Sir why should not provided at other than center of the column

  • @a1teluguconstruction245
    @a1teluguconstruction245 3 ปีที่แล้ว

    Nice sir

  • @a1teluguconstruction245
    @a1teluguconstruction245 3 ปีที่แล้ว

    Sir why should not provided at other than center of the column