We have these things ALL OVER the facility I work at, and never have a problem with them. Amazingly, not even any problem with galling, which stainless does ALL the time with other hardware we have around here...
You'd be surprised how often this happens. Usually an operator just not paying attention. You really need to double or triple check that the system is depressurized.
@@24680kong One needs to utilize a proper LOTO Program. Then there is no way that one can end up opening a system and exposing themselves to hazardous energy if one uses LOTO properly. It is hard to believe that ANYONE does this but I know that they do.
Is it acceptable to use a very small amount of anti seize on the thread to prevent galling? I have some that we disconnect and reconnect many times. They get tight before they are actually tight , I assume it is the friction from the stainless.
Hi Adam, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
I am no expert but I have used the many years. You should replace the fitting. This is not natural under proper care and cleaning of the threads. Inspect the threads of the nut and union and I bet they are damaged, look especially at the first round since you are having issues getting it started.
Hi V Vickraman, Your local sales and service center will be happy to help. You can find their contact information here: products.swagelok.com/en/locator
Hi Lorenzo, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
Hi Vinay, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
We are using 4mm copper tube also but facing leakage problem We are using our product for 6mm SS tubing Pl suggest solution on cooper tube leakage for argon gas at level 10 rase to -8
Hi Vinay, We are happy to help you. Please contact your local sales and service center regarding your question. Contact information can be found here: www.swagelok.com/en/locate-a-sales-service-center
good evening sir I want a water mist pump room detail video Because I am doing this work first time So i'm very hard at it So i need you to help me Make me a detail video in it How does the transmitter sound And how do indicators Classical and used in this How to install them
Hi Maqsood, Your local sales and service center will be able to answer your questions. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
Hello Swagelok world. I'm using 1/8" tubing's and fittings. (4ft of tubbing , 2x Ball Valves, 2 Tee connections) But I'm having pressure leak when testing with N2 at 1200psi. The leak rate is about 2 psi in 10min. I (supposedly) followed the recommendations to make the connections. I have been using SNOOP , but I cannot detect the leak. I've inspected and tightened ever connection, but still have pressure leak . Any idea what could be wrong? Anyone recommend using a sealant? Thanks!
Hi Carlos, Your local sales and service center will be able to answer your question. Please contact their customer service department. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
Wait a sec. We have always been told not to use a round bladed tube cutter. We're supposed to use a hacksaw type of cutter. If you look at 1:13 that tube was cut with a hacksaw - not a round bladed cutter. What gives?
Hi Chuck, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
Hello, Your local sales and service center will be able to help if you need assistance. You can find their contact information here: products.swagelok.com/locator
We have these things ALL OVER the facility I work at, and never have a problem with them. Amazingly, not even any problem with galling, which stainless does ALL the time with other hardware we have around here...
Very happy I found this channel!! Keep it up please
Hi Daniel, please email me: daniel@nai-lok.comm.cn, Skype: daniel0502, WeChat: daniel-jjy. we manufacture valves and tube fittings in Shanghai China.
I always cringe when I see people crank down on these fittings, and they don't believe me when I say it's only one and a quarter turn
VIS-LOK has tightening indicators
Yeah cranking down just flares the ferrule and gives you less metal to metal sealing surface. It also produced a lot of heat on the threads… so stupid
Awesome. Saved me from a headache.🤙🏽🤙🏽
How about with soft nonmetallic tubing? PTFE, PVC etc.
Thanks ,I realy was in need for this video
Very good hydraulic Tube nut and Fearul Tightness Setting.
Depressurize the system BEFORE disassembling the fitting?
THAT'S what I have been doing wrong.
Thanks Swagelok!
You'd be surprised how often this happens. Usually an operator just not paying attention. You really need to double or triple check that the system is depressurized.
@@24680kong
One needs to utilize a proper LOTO Program.
Then there is no way that one can end up opening a system and exposing themselves to hazardous energy if one uses LOTO properly.
It is hard to believe that ANYONE does this but I know that they do.
@@judsonkr LOTOTO is mandatory at my workplace. Lock out / Tag out / Try out
Where I can get one of those deburring tool?
we never use hack saw to cut instrument tubing...
yes kabayan, sobrang selan lalo baka pumasok yung burrs sa loob.
What’s the model on the tube deburring tool?
Thanks for sharing!
Is it acceptable to use a very small amount of anti seize on the thread to prevent galling? I have some that we disconnect and reconnect many times. They get tight before they are actually tight , I assume it is the friction from the stainless.
Hi Adam, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
I am no expert but I have used the many years. You should replace the fitting. This is not natural under proper care and cleaning of the threads. Inspect the threads of the nut and union and I bet they are damaged, look especially at the first round since you are having issues getting it started.
Can you make one video for 3/4" tubing
Hi V Vickraman, Your local sales and service center will be happy to help. You can find their contact information here: products.swagelok.com/en/locator
Excelent video, very Nice explication
perfect work.
If I use a Duplex pipe, it needs a fitting specific for this material? Please🙏🏽 The Pipe is 1/2 O.D. Thickness 1,6 mm
Hi Lorenzo, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
Very good
Which is good option for tube cutting hexca or tube cutting tool by swage look
Hi Vinay, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
look at microgroup tubing cutter, use it all day www.microgroup.com/product-category/saw/
We are using 4mm copper tube also but facing leakage problem
We are using our product for 6mm SS tubing
Pl suggest solution on cooper tube leakage for argon gas at level 10 rase to -8
Hi Vinay, We are happy to help you. Please contact your local sales and service center regarding your question. Contact information can be found here: www.swagelok.com/en/locate-a-sales-service-center
This was perfect.
this shit kicks assssss......
really like these fittings..
3:22
I need this tutions
good evening sir
I want a water mist pump room detail video Because I am doing this work first time So i'm very hard at it So i need you to help me Make me a detail video in it How does the transmitter sound And how do indicators Classical and used in this How to install them
Hi Maqsood, Your local sales and service center will be able to answer your questions. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
Hello Swagelok world. I'm using 1/8" tubing's and fittings. (4ft of tubbing , 2x Ball Valves, 2 Tee connections) But I'm having pressure leak when testing with N2 at 1200psi. The leak rate is about 2 psi in 10min. I (supposedly) followed the recommendations to make the connections. I have been using SNOOP , but I cannot detect the leak. I've inspected and tightened ever connection, but still have pressure leak . Any idea what could be wrong? Anyone recommend using a sealant? Thanks!
Hi Carlos, Your local sales and service center will be able to answer your question. Please contact their customer service department. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
Wait a sec. We have always been told not to use a round bladed tube cutter. We're supposed to use a hacksaw type of cutter. If you look at 1:13 that tube was cut with a hacksaw - not a round bladed cutter.
What gives?
Tom Servo fd
www.microgroup.com/product-category/saw/
How can I adapt this to iron pipe?
Hi Chuck, Your local sales and service center will be able to answer your question. You can find their contact information here: www.swagelok.com/en/locate-a-sales-service-center
pipe and tubing are two completely different things. The simple answer is NO.
What happens if I srew it more than 1 1/4 turns? Lets say 2 turns...
The tube inside the fitting will over expand and will be harder to remove and reuse
@@solexxx8588 LMAO
that's nice thanks for uploading. :-)
Pravin Kumar
1/8 tube does not allow 1-1/4 turn
Hello, Your local sales and service center will be able to help if you need assistance. You can find their contact information here: products.swagelok.com/locator
Nice present, thanks.
Good
Nice
What the fuck is a pre swaged farrow
From the looks of it a swage tool is req.
HVAC guy, this is new to me too.
Ok
K
Is so dumb that they domt let you buy their products
Hindi
Awesome. Saved me from a headache.🤙🏽🤙🏽
Very good