Teds Fishroom Air

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ก.ย. 2024
  • Tips on planning and installing an air system in a fish room.

ความคิดเห็น • 22

  • @flashofpink
    @flashofpink 10 ปีที่แล้ว +3

    This is so helpful, thank you!

  • @AquariumsAnonymous
    @AquariumsAnonymous 5 ปีที่แล้ว +1

    thanks for this! even 8 years later still relevant

  • @MadHattersReef
    @MadHattersReef 12 ปีที่แล้ว

    A lot of great hard to find Info in this video. Thanks!

  • @Pure4Kicks
    @Pure4Kicks 11 ปีที่แล้ว

    Installed mine last night :) best investment in the fish room yet.

  • @bobbygsproaquarium
    @bobbygsproaquarium 6 ปีที่แล้ว

    Good video, thanks for posting!

  • @TedsFishroom
    @TedsFishroom  11 ปีที่แล้ว

    The air delivery should be above the water to prevent back siphon in the case of a power failure. If I were doing this in a 'finished' display room I would put the pipe just at the highest tank and use check valves.

  • @kingjamwi
    @kingjamwi 11 ปีที่แล้ว +1

    Is the needle valve thread type standard and is the thread tapping tool also standard? If not what type of tap did you use?

  • @TedsFishroom
    @TedsFishroom  11 ปีที่แล้ว

    Different valves have different threads. Buy them from Jehmco and they can sell you the right tap to match each type of valve.

  • @MrFiat124Spider
    @MrFiat124Spider 12 ปีที่แล้ว

    Great info!

  • @ericmurray9045
    @ericmurray9045 5 ปีที่แล้ว +1

    Thanks the information is great but where can I get the Valve and tap to buy

  • @sprydell1
    @sprydell1 11 ปีที่แล้ว

    why does the tubing need to be high in the room? wouldn't it look better if is was hidden?

  • @TedsFishroom
    @TedsFishroom  12 ปีที่แล้ว

    I got it at jehmco.com. Not sure of the brand. It is the only linear piston brand Jehmco sells.

  • @bobluckey
    @bobluckey 11 ปีที่แล้ว

    On your recommendation, I constructed a small, 3/4" PVC, closed loop system with a larger valve to bleed off unused air in order to avoid excessive back pressure for my Jehmco LPH26. Do you use a check on your system and if so what kind? Most of the check valves reduce the airflow to 1/2" or smaller. While I use individual check valves on all my airlines, I am unable to mount the pump higher than my tanks. Should I use a check valve or are the individual valves sufficient?

  • @csquarebooth
    @csquarebooth 12 ปีที่แล้ว

    What brand and model is your linear piston air pump?

  • @maileen420
    @maileen420 8 ปีที่แล้ว

    "small bubbles from air stones make filters run more efficiently" can you elaborate on that? or did you just mean that newer sponge filters make smaller bubbles, and should be switched out when that changes.

    • @TedsFishroom
      @TedsFishroom  8 ปีที่แล้ว

      +maileen420 When there are a lot of small bubbles filling the lift tube, the combined surface area of all the bubbles together push more water than the relatively small surface area of a few large bubbles.

    • @maileen420
      @maileen420 8 ปีที่แล้ว

      +Ted Judy got it, the whole "air stone" thing threw me off, thanks!

  • @beautyvsdeath
    @beautyvsdeath 8 ปีที่แล้ว

    I want to have a fish room when I'm older, do you have an approximate budget I will need to obtain to make this?

    • @TedsFishroom
      @TedsFishroom  8 ปีที่แล้ว

      Overall cost varies depending upon the size of the space and the how much automation you want to install. The room in the video you comment is attached to cost me about $5000. My current fish room would be less expensive (many fewer tanks)

    • @beautyvsdeath
      @beautyvsdeath 8 ปีที่แล้ว

      Thank you!!