Convert R22 refrigerant coil to R 410 refrigerant

แชร์
ฝัง
  • เผยแพร่เมื่อ 18 ต.ค. 2024

ความคิดเห็น • 36

  • @jeffchambers9560
    @jeffchambers9560 2 ปีที่แล้ว

    Just came across this video, so it can be done! Was curious about the conversion. As far as just replacing the piston, if you want to live in the land of 10 SEER ratings, go for it. As of today, wish you luck on finding pistons. Good job Bro! If Technicians stayed "inside the box" we would get nowhere. Again, nice job!

    • @waisHVAC
      @waisHVAC  2 ปีที่แล้ว

      My friend expansion valve has nothing to do with Seasonal energy efficiency, As long as your coil is built for higher pressure above 450 psi. And you can convert 13 or 14 seer R. 22 to R 410 but if you are installing a 16 SEER system You will need a bigger body size coil and also Variable speed furnace

  • @sadsamr-un8rl
    @sadsamr-un8rl 4 หลายเดือนก่อน

    عملا رائع شكرا على جهودك المبذولة لايصال المعلومة المفيدة لنا عن هذا الجهاز المتعب في صيانته

  • @anvibrimel41
    @anvibrimel41 3 ปีที่แล้ว +4

    Very good video keep doing it, thanks a lot

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว +1

      Thank you very much for your nice comment and I appreciate your support

  • @abdulhvac2395
    @abdulhvac2395 3 ปีที่แล้ว +3

    Thank you for sharing keep posting

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว

      Thank you, I will

  • @bimalradia1969
    @bimalradia1969 2 ปีที่แล้ว +1

    @ALL THING HVAC / Wais Heating and Air Condtioning - I have a Goodman 3.5 ton condenser with 407C freon. I am replacing it with Lennox XC16S048-230, 4 ton, 2 stage, 410A condenser. The evaporator coil says that it is good for 410a, R22, R12, R-500, R502. 350 PSI. A/c tech says that he will replace the piston and make it work. Should I ask him to install TXV valve instead or how best to handle it? Please advise.

    • @waisHVAC
      @waisHVAC  2 ปีที่แล้ว +1

      Hi
      He is wrong, First make sure your coil is a high-pressure coil, above 450 psi , R410 is High pressure refrigerant , and it will not work good with piston and 2nd every Freon has their own expansion valve, special R410 A , and R22, so when you’re installing a 410A condenser you have to install expansion valve, and last when you say 2 stage condenser and you have a 80% standard furnace that will not give you more then 14 SEER ,
      For 16 SEER or higher efficiency You need a variable speed furnace and also a big cabinet Coil, and minimum 18’’ return Duct
      Thanks

  • @tahoe6182
    @tahoe6182 3 ปีที่แล้ว +2

    I feel your pain its hot in tx too haha

    • @fidelgarcia5683
      @fidelgarcia5683 3 ปีที่แล้ว

      @Soren Damon I see this same comment in different videos. What's the scam?

  • @matthewportnoy4146
    @matthewportnoy4146 3 ปีที่แล้ว +1

    Why didn’t you just replace the flowrater (orifice/piston) with a 410a type I do it to dozens of units and carry all sizes to save time and money on a TXV? I have great success with straight q CL A/C or heatpump

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว

      Yes you can use piston too but The TXV can vary the amount of refrigerant flow through the evaporator by opening and closing in response to evaporator heat load. Compared to a fixed orifice, a TXV operates more efficiently in varying environmental conditions (theoretically, at least).

    • @matthewportnoy4146
      @matthewportnoy4146 3 ปีที่แล้ว +1

      @@waisHVAC great what ever works for you but in 41 years in HVAC I replaced dozens of TXVs, TEVs and only “1” orifice

    • @KendoesHVAC
      @KendoesHVAC ปีที่แล้ว +1

      @@matthewportnoy4146 how do you know what piston size to use exactly ?

    • @The1realro
      @The1realro 8 หลายเดือนก่อน

      @@KendoesHVACgreat question ever found the answer ?

  • @bruce8572
    @bruce8572 13 วันที่ผ่านมา

    What hackery! Using a Vice-grip pliers............!!

  • @tahoe6182
    @tahoe6182 3 ปีที่แล้ว +1

    Too covert it too r410 all you have to do is change expansion valve ?

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว

      Did you see the Complete video?
      I installed the Expansion valve and also Welded a service valve to connect with the expansion valve to it.

    • @matthewportnoy4146
      @matthewportnoy4146 3 ปีที่แล้ว

      You don’t even need to do that just replace the piston/orifice that comes with the new condenser

    • @willb.9225
      @willb.9225 2 หลายเดือนก่อน

      That's what I thought as well...​@@matthewportnoy4146

  • @geniusliu143
    @geniusliu143 3 ปีที่แล้ว

    hi , for convert r22 to 410a on the metering device . can i just put a correct size piston without txv ?

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว

      Yes you can but please make sure your coil is above 380 psi

    • @geniusliu143
      @geniusliu143 3 ปีที่แล้ว

      @@waisHVAC u mean make sure evap coil can handle above 380 pressure . >?

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว +1

      @@geniusliu143 yes please

    • @geniusliu143
      @geniusliu143 3 ปีที่แล้ว

      @@waisHVAC thank u 👍

  • @filibertoleyva5312
    @filibertoleyva5312 2 ปีที่แล้ว

    How is the name,that valbula oh how I ask in the store... please 🥺 thank you.

    • @waisHVAC
      @waisHVAC  2 ปีที่แล้ว +1

      I think you are asking about the expansion valve or TX valve,

  • @alvincee7605
    @alvincee7605 6 หลายเดือนก่อน

    ❤❤❤

  • @KenMagee
    @KenMagee 3 ปีที่แล้ว +1

    Just a word of advice. You seem knowledgeable enough. Perhaps the reason you weren't getting the views you wanted was poor production. A bunch of background music is annoying for most people. Especially the same old same old royalty free garbage. Also when you performed much of the work it was out of frame. You also keep putting tools and garbage in front of the camera blocking view. Just the few things I noticed. If you ever decide to get back after it, work on those items and you could possibly get better views.

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว

      Thank you brother for your advice. The only reason I put music so people don’t hear our Private conversations. Our videos are hours long and sometimes we take videos from the entire job, a lots of time the customers are talking or we are talking and also the back ground Noises are there so we have to cover all those conversation and noise with free music.

  • @johnszymanski548
    @johnszymanski548 3 ปีที่แล้ว

    Hope the coil was rated for 250psi test pressure it's it's 150psi you can't do that .

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว

      Of course I always check the psi on the coil. it has to be above 380 psi or I will change the coil completely all conversion will be Based on rating of Pressure on the coil, the video shows how to change or install a EXP valve, and on this video I am not Suggesting to install a R 410 condenser with our 22 coil,

  • @702havingfun
    @702havingfun 3 ปีที่แล้ว

    Do you have to replace the evaporator?

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว +2

      You can change the evaporator coil or just replace the Expansion valve,
      But I recommend to install a expansion valve it’s cheaper and a lot faster too

    • @waisHVAC
      @waisHVAC  3 ปีที่แล้ว

      @@jrsmyth9761 I know Enough to have 50 employees like you