Sir hr zone ka separately alarm buzz nhi hoga kya.. Jaise 4 floor hai 4 floor pr ek ek alarm lga hai to man lo 4th floor pr aag lagi ho tb kya only 4th floor ka hi alarm buzz ho skta hai ya all 4 floor ka ek sath buzz hoga
Dono system ho skte hai All floor ka bhi alarm aa skta hai ya fir sirf ussi floor ka alarm aayega jis par aag lagi hai You have to select fire alarm accordingly
Sir fire panel zone me MCP Kaha lagaya jata hai, detector se pehle 1st MCP fir detector, ya last detector ke bad end me, ya koi bhi detectors ke bich me kahi bhi ?
Aap ka video bahut hi la jabab he sir aap ki video dekh kar koi bhi admin asanise chamaz payegi thank sir
Thanks sir
Very nice and detailed! Thank you so much!
Bahot mast sir bahot aachi video banayi hai apne thnkssss sir
Sir aap video bahut hi achha laga h
Sir video bohat mst he samjaneko khup he
bhoot àcha sa explain ki sir ❤️
sir appki video mujha bhoat Acche lagti hai sir plz intercom ky upeer video banyooo sir complited video sir tanxxx sir
Ok sir
Awesome video thankyou for uploading 🙏
Love you ❤❤❤
Very good video
Sir Bosch ki setym h ek control model se 6 hutar loop h. Chalga ya nhi batana
Please halo me
Chalna to chahiye sir but maine Bosch par kaam nahi kiya
Very nice 👍 thank you sir
आप जो जानकारी देते हो भैया वो बहुत सिंपल होती है मुझको बहुत ही हेल्प मिलती है अगर आप का नंबर मिल जय तो सादूबाद होगा भैया
Sir addressable fire alarm system per video banye
Ok sir
hi sir, agar hum zone pr he kaam kar rahe h toh EOL baaki 7zone me lagega?
MCP me to mandatory h
Hello sir aap ne jo panel bataya same panel hai usme kisi ek zone me on/iso me yellow light stabal hai so pleas help me
Very nice video
I like you
Well done sir
Panel ke zone me register bhi lagana padega ya sirf +- ki detector ki wire hi lage gi
Zone ke last me lagega EOL
👍👍 good sir
❤❤❤❤good
Jo zone hum use nahi kRtay to uska risitorn nikal na padta hai ya waise hi lagana rahe de na padta hai
Bahut sundar hai
Sir panel ke aandr ki wiring pr 1 vedio banao detel me plise ❤
Very nice sir
Thanks sir 👍
Sir hr zone ka separately alarm buzz nhi hoga kya..
Jaise 4 floor hai 4 floor pr ek ek alarm lga hai to man lo 4th floor pr aag lagi ho tb kya only 4th floor ka hi alarm buzz ho skta hai ya all 4 floor ka ek sath buzz hoga
Dono system ho skte hai
All floor ka bhi alarm aa skta hai ya fir sirf ussi floor ka alarm aayega jis par aag lagi hai
You have to select fire alarm accordingly
@@GreenTechSolutions thnnxxx u sir 🙏 👏
Sir kabhi repeater ki wiring diagram batayen
Nice video❤
1 zone me kitna device laga skte h sir
20 detector max
Thank you brother
very good sir
Add firm panel ka video same bannna ke daalo
Ok sir
Bina ac ke konsi battery se kam kre ga
It can connect 12 volt 7 amp battery & also connect to the inverter
Sir 24 volt fire hooter ko 24 volt power supply pa direct chala sakte hain shortcircuit nahin Karega
Hanji kar skte hai
Cm 6hutar loop
Very nice
Sir kishi ek ko bajna hoga to huye ko
Sorry question smjh nahi aaya fir se btayegen plz
Super sir
great video. thanks
Sirji. Pumpkakambtaa
8 zone panel me kitna smoke detector laga sakte ha
Par zone 20 detector
Nice video
Good
𝙕𝙖𝙗𝙖𝙧 𝙙𝙖𝙨𝙩
Thanks sir
Sir fire panel zone me MCP Kaha lagaya jata hai, detector se pehle 1st MCP fir detector, ya last detector ke bad end me, ya koi bhi detectors ke bich me kahi bhi ?
Kahi bhi laga skate hai main door pe laga na
Sir detectors manual point and hooters height Kitna
MCP hight should be 4 to 5 feet
Hooter hight should be 7 to 10 feet
@@GreenTechSolutions thanks for reply sir
10 zone fire alarm panel me kitne MCP Hooter lagte h
Per zone 12
Nice
Sir why put resistor
To complete the circuit
@@GreenTechSolutions thanks sir I have another doubt
फायर अलार्म का काम करने के लिए गवर्नमेंट ऑथोराइज्ड कि जरारत पड़ता है या कोई भी सीसीटीवी या इलेक्ट्रिकल काम करने वाला फिक्सिंग कर सकता है ???
Sir aap se request h ki jis tarah se Conventional Fire alarm ka video banaye h same usi tarah se address panel ke bare me v bataye plz
Ok sir
Ek jone me kitne detector use kar sakte hi
Simplex panel me last 255& notifier panel me 159 total
thanks
Where to purchase from?
You can purchase from agni devices or we can also provide you
@@GreenTechSolutions can you provide agni Devices contact person number
Need spares
Sir mujhe job dilwa do fire me
Sir aapka no hona tha
Ek problem kr liye
Galat jankari de rhe ho aap
Sir need your number
hi sir, agar hum 1 zone pr hi kaam kar rahe h toh EOL baaki 7zone me lagega?
MCP me to mandatory h
Very nice
Good job
Very good