Very good explanation, i have a job i want to do soon.. I will so much appreciate it if you go further to do the hooter connection and resistor in practical, thank you God bless you
I'm a fire alarm technician .my point is that all the detectors have the address so why do you wast so much fire wire and use the resistors at the end of line ? the cable loops from the panel one cable goes out and one return cable comes in simple why making things complicated the resistors are installed in the fire panel not 10.000 cables in the fire panel . the panel speaks for it self as the sensors . just trying to save you time and money thank you
Good work!
Fire alarm system very well explained with necessary details👍👍👍👍
Thanks for knowledge Mr engineer
ကျေးဇူးပါ ဆရာ FA Panel ကော
FA devices connection လေးတွေ မျှဝေပေးပါ ဆရာ
Gd ❤
Good Explanations
Very good work,well noted 💯,well explained
Thank you so much for the clear explanation.
Sir you just help me with your knowledge🎉🎉🎉🎉
Very good explanation, i have a job i want to do soon..
I will so much appreciate it if you go further to do the hooter connection and resistor in practical, thank you God bless you
Thank you so much for sharing your valuable knowledge,
Would you please clarify how to select the EOL resitor
how do you calculate the value of EOL resistor
Thanks for ur teaching
Very Nice 😊
Nice one thanks for the video ❤
Thanks for the explanation.
Please explain wiring for intelligent fire alsrm system
Nice one
Very good
Thanks for your valuable information. A small dought how many detectors can we installed in single zone?
God bless you
what resistor value must be used on EOL?
How many beam, smoke, flame, heat, detector can be connected in single zone
Can we do the fire alarm without addressable panels
Ask a more understandable question cos I'm sure he did the none addressable connection, so what exactly are you asking?
Good job
Please what application did you use to do this video animation
Thanks sir,but how do I connect the ringer or bell
FIRE ALARM CONTROL PANEL ---- SMOKE DETECTOR --- HEAT DETECTOR --- MCP --- EOLR. is this ok ?
Where is the sounder or Hooter?
🇧🇩🇧🇩🇧🇩🇧🇩🇧🇩🥰🥰🥰🥰
Hindi me batao na please
Merc
I'm a fire alarm technician .my point is that all the detectors have the address so why do you wast so much fire wire and use the resistors at the end of line ? the cable loops from the panel one cable goes out and one return cable comes in simple why making things complicated the resistors are installed in the fire panel not 10.000 cables in the fire panel . the panel speaks for it self as the sensors . just trying to save you time and money thank you
but this is a conventional control panel not addressable
It's a Coventional fire alarm
Good morning electrical guy I want your number to chart with you
Thank you so much to good explanation god bless.. very good lesson