There are basically two reasons 1. After cracking reaction product leaves from VSS chamber and falls on stripper packing, here we provide stripping steam in order to strip off trapped hydro carbon from catalyst. So that only spent catalyst should go to the regenerator not hydrocarbon. 2 How much amount of stripping steam we give it depends on regenerator dense bed temperature, if dense bed temperature drops we reduce stripping steam and vice versa.
nice presentation. which digital tablet you have used for your presentation and writing on screen?
Sir why we use stripping steam in this unit
There are basically two reasons
1. After cracking reaction product leaves from VSS chamber and falls on stripper packing, here we provide stripping steam in order to strip off trapped hydro carbon from catalyst. So that only spent catalyst should go to the regenerator not hydrocarbon.
2 How much amount of stripping steam we give it depends on regenerator dense bed temperature, if dense bed temperature drops we reduce stripping steam and vice versa.
Thank you so much
Sir, material balance kaise kare uss topic par ho sake to video banay please.
Sir isska details pfd ho to uss par video banay please ho sake to
Riser reactor & regenerator
Do you teach offline
No I don't teach offline
Sir i am fresher student and want do doing a job plese guide me
Connect me @ corechemicalengineering@gmail.com