Upgrade Bathroom Fan - Reduce Shower Moisture

แชร์
ฝัง
  • เผยแพร่เมื่อ 14 ต.ค. 2024
  • After remodeling my bathroom with a shower six months ago, I noticed signs of moisture on the walls after. I decided to take a closer look at the exhaust fan. Upon further investigation, I determined the fan was ultimately under-powered. Time to upgrade and double the power!:)
    If you see moisture on your bathroom walls, take a closer look at the fan. If the fan fails to pull air, consider replacing. If the fan pulls air, consider upgrading to a larger capacity.
    Broan AR110: amzn.to/2Lyv2wh
    NOTE: considering using a Romex clamp around the 18:45 mark in the video when feeding the wires through the hole, as this might be required by code in your location.

ความคิดเห็น • 572

  • @RealWorld
    @RealWorld  5 ปีที่แล้ว +27

    I have been meaning to drop a link for a great timer which can be found here - amzn.to/2SLYEZU ... runs about $17 and seems to be solid/reliable. This will allow you to leave your fan running for a preset amount of time when you leave the room. A very handy feature.

    • @TejasToolMan
      @TejasToolMan 5 ปีที่แล้ว +2

      Squirrel cage unit was a good choice, it'll make a ton of difference I put these in all my rent houses =)

    • @abe677
      @abe677 4 ปีที่แล้ว +2

      I put similar switches in my 2 bathrooms and they make a difference. In the humid summer months I'd say that 30 min isn't long enough. Our timer values are 5, 10, 30, 60, 120, 240 (minutes).

    • @mackfar27
      @mackfar27 3 ปีที่แล้ว +2

      Now, just add a Leviton Humidistat sensor switch to control your new bathroom fan. This way your fan will automatically come into action when you are taking a shower.

    • @fayb6389
      @fayb6389 3 ปีที่แล้ว +1

      @@TejasToolMan . . @

  • @fedupwitumboth
    @fedupwitumboth 4 ปีที่แล้ว +13

    My husband developed macular degeneration, he’s an electrician (retired) by trade. I’m going to be installing a new vent in our bathroom with instruction from him, I’ll be his eyes, this video was very helpful! As a 68 yr old woman I’ve installed a new chandelier and this is my new “project”. Thanks!

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +3

      Glad to be of help and God bless:).

  • @jasperjasper1435
    @jasperjasper1435 7 ปีที่แล้ว +54

    Just as a note for any do it yourselfers out there that will watch this video. Please remove the "romex clamp" from the old fan or purchase a new one to protect the romex wire as it enters the fan box. If you do not install the clamp the wire may rub against the side of the box, which is very sharp, and could eventually short out the circuit.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +7

      thank you for the post and great point!:) I went without the clamp but better to be safe than sorry.

    • @bguen1234
      @bguen1234 5 ปีที่แล้ว +9

      If the wire in your attic is moving on it's own you have a bigger problem.

    • @narlycharley
      @narlycharley 4 ปีที่แล้ว +20

      @@bguen1234 it's a fan assembly that vibrates, even if it's just a very small amount. If that fan runs every day for 10+ years, you could have problems.

    • @aLortizable
      @aLortizable 3 ปีที่แล้ว +2

      I was so surprised when no romex clamp was used. I don't think people come to these sites for wrong information.

  • @jazzer770
    @jazzer770 4 ปีที่แล้ว +30

    without a single cuss word. amazing how you're so calm. I've got a lot to learn. well done, sir.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +2

      LOL - thanks for the post:).

  • @Aurleis
    @Aurleis ปีที่แล้ว +3

    I have a Ventline V2270-50 that I need to swap out to a Panasonic FV-1115VK2. I calculated that my bathroom requires 114 CFM (current fan is only 50 CFM and around 79 dB). New Panasonic is 11 dB and 150 CFM. Given the dimensional differences, your video tutorial was EXACTLY what I needed. Thank you for taking the time to put this together.

    • @RealWorld
      @RealWorld  ปีที่แล้ว +1

      glad to be of help and good luck with your project! :) my bathroom is much better since replacing the fan.

  • @lindarivers2407
    @lindarivers2407 4 ปีที่แล้ว +17

    Just a note: If there are two pieces of wiring coming into the fan housing, one of them is a switch leg going to the switch and the other one will be the hot feed and will be live unless it's shut off at the breaker. You should also never run wiring through a sharp hole in sheet metal. A screw in connector that clamps the wire and protects it from the sheet metal edges is code.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      Agreed and thanks for the feedback:).

  • @mistynutt6295
    @mistynutt6295 5 ปีที่แล้ว +3

    Thanks for this post and the comments....with the info we pre-purchased all the possible things we could need, and we ended up needing all of them, however, with your advice, start to finish it took us just over 2 hours to remove and replace!

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Glad to be of help Misty!:)

  • @mikeimparato824
    @mikeimparato824 6 ปีที่แล้ว +16

    At12:25 I would recommend that blocking be added for the fan housing support to the non-joist side of the housing.
    Cut a short piece of 2 X 3, lay up above drywall flush to opening and run a couple of screws up thru the drywall to retain the blocking.
    The screws will not be seen. They will be covered by the fan grill when it’s installed.
    This blocking support will remove any housing sag and unwanted vibration of the unit.
    You could also use what is known as “OWC” clips. By cutting two notches about 2” from each corner and attach them, and then expand them till the housing flange comes snug to the drywall.

    • @yerthao2246
      @yerthao2246 5 ปีที่แล้ว

      I was wondering how to do screw it on the side with no joist and this helps! thanks for the tip.

    • @stephenmehallo3902
      @stephenmehallo3902 4 ปีที่แล้ว

      Great idea..I was wondering how he was going to support the other non-stud side-thanks for the tip as I am faced with the same stud/no stud situation.

  • @Wakeywhodat
    @Wakeywhodat 4 ปีที่แล้ว +7

    Nice install.. This is one of the first upgrades I make after moving - replacing the builder grade exhaust fans (along with the stove hood vent). I select the strongest motor with the quietest operation (measured in db’s). The quiet ones cost more, but for me that is important for any exhaust fans in the home.
    If accessible, I always go into the attic to firmly attach the vent with quality duct tape or even better, one of those 2 or 3 foot HVAC style zip ties. Also I caulk around the housing where it meets the Sheetrock and then tighten up the insulation around the base. Less air leakage from the fixture and no dust or debris from the attic. I like the timer you posted, it’s now in my Amazon cart.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      Thanks for the post/feedback/tips:).

  • @mikemclean516
    @mikemclean516 7 ปีที่แล้ว +7

    The only suggestion for this type of retrofit is that, if it were a heavier unit, you could add a wooden batten to reinforce the drywall opposite the joist and a couple of screws up through those available holes in the lip of the casing would make it very rigid (the drywall ends up firmly sandwiched between the lip below, and the wooden batten above). This also minimises any air being sucked down from the joist space. Thanks for the video.

  • @rickames3621
    @rickames3621 2 ปีที่แล้ว +3

    This was great! I’m also adding a bigger exhaust fan to my bathroom with no attic access and you didn’t skip any of the steps that I didn’t see on other videos. Thank you for this!

  • @FatPeaches330
    @FatPeaches330 6 ปีที่แล้ว +9

    I have these same exhaust fans in my house built in '99. I've been playing around with the idea of replacing them and this video was super helpful. Thanks so much!

    • @RealWorld
      @RealWorld  6 ปีที่แล้ว

      Thanks for the post Ben and glad to be of help!:)

  • @zahkiyyah
    @zahkiyyah 11 หลายเดือนก่อน +1

    This is one of the best well-informed bathroom exhaust fan videos that I have seen thus far. Thanks for taking the time to show each step in detail. I feel more confident with doing it myself and saving money. Thanks.

    • @RealWorld
      @RealWorld  9 หลายเดือนก่อน

      glad to be of help!:) if i can do it, so can you!:) years later and the fan is running great!:)

  • @jamescrawford5330
    @jamescrawford5330 ปีที่แล้ว

    Attacked my apartment bathroom vent fan last night and planned on replacement. Another video suggested that lubricating the motor might help. Low and behold, after a couple of drops of WD-40, the blower ran like new!! Old apartment so this also gave me a chance to clean the fan and the casing. Your video is excellent and most attentive to details. Will subscribe and watch for further tips. Thanks!!

  • @keithp115
    @keithp115 3 ปีที่แล้ว +1

    I'm four years late, but your post encouraged me to change out my 20 year old exhaust fan. Great job and thanks much!

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว +1

      LOL - never too late:). Glad to be of help and good luck!:)

  • @melissademarco1466
    @melissademarco1466 4 ปีที่แล้ว +3

    You are a fantastic instructionalist. Thanks for the installation guide. After watching your video, I feel confident that I can choose an adequate new fan and safely install it correctly on the first try!

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      Glad to be of help Melissa and good luck!:)

  • @bdgs34
    @bdgs34 3 ปีที่แล้ว +1

    Excellent video. Was facing similar dilemma of underpowered fan for square footage needed. Best step by step I have seen. Thanks

  • @barbarat5729
    @barbarat5729 6 ปีที่แล้ว +2

    I don't understand why anyone would give this video a thumbs down. As a woman and someone who wasn't raised being shown this stuff, I GREATLY appreciate these videos.

    • @RealWorld
      @RealWorld  6 ปีที่แล้ว

      Thanks for the post/feedback Barb and glad to be of help!:)

  • @wongkeeleong
    @wongkeeleong 4 ปีที่แล้ว +1

    I wonder how Google knew that I had a noisy exhaust fan to be replaced! I'm glad they did because this is an awesome DIY video. Thank you for posting.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      LOL - I know what you mean - the power of AI (artificial intelligence):).

  • @DavidA-411
    @DavidA-411 4 ปีที่แล้ว +1

    I took my exhaust fan out. Saves a lot of money and it's much more comfortable.
    I just use a squeegee after the shower. I do the walls and shower curtain in the tub area and it works like a charm.
    No fan noise, Nothing to ware out. No heat loss in winter.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      interesting though although continuous moisture might cause mold and various other unwanted effects:)

    • @DavidA-411
      @DavidA-411 4 ปีที่แล้ว +1

      @@RealWorld As long as you don't leave the door closed, and you squeegee the tub walls and curtain every time, there hasn't been a problem in my bathroom for some 20 years so far.

  • @johncarlen2476
    @johncarlen2476 5 ปีที่แล้ว +3

    Good vid. When buying new, make sure the fan can be easily removed from housing for cleaning and lubrication. Do not use powerful blower when cleaning, too much force will break the plastic fan, especially as it gets older and more brittle.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Thanks for the tips John ... good points to note:).

  • @jimmysmith9957
    @jimmysmith9957 ปีที่แล้ว +1

    Very good video. Especially giving how to calculate the proper vent size for the bathroom. One suggestion: The ground wires do need a wire nut on them. The purpose is to be sure there is a firm connection between the wires so if a short does occur in the fan housing there is a path to ground. Without the wire nut on the ground wires the resistance could possible become to high for the ground path to function properly or the wires could become accidently pulled apart.

  • @glockbell
    @glockbell 3 ปีที่แล้ว +1

    I thought I knew what I was doing, but kept chickening out. This video gave me the confidence to proceed. Thanks for the explanations.

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      if i can do it, so can you! :)

  • @raypatino2610
    @raypatino2610 ปีที่แล้ว

    Very nicely explained, step by step. My biggest concern was going to be taking down the old housing since I couldn't see how it was attached, and I have the same as yours. Time to get the pry-bar!!! Thanks!

  • @siku5it
    @siku5it 5 ปีที่แล้ว +2

    This was very good. It helped me doing the job and had all the right information. - Thank You for this, you have all my gratitude. - I wanted to add what made my experience 1h longer than it should have been. My house if full of "atypical" vent conduits. Instead of flexible tubes from the vent to the fan, they used all over those rigid metallic tubes made by curling a sheet of metal and spot wielding it into a tube. The result is a very crappy and difficult to deal system. I had a 3 inches steel tube and I knew the new unit would have a 4 inches outlet. So I bought some flext 3 inch tube and a 'reducer" in light plastic (from 4 to 3 in) so that I could 1) Extend the metallic tube without disturbing it too much from the current position 2) Extend the flex tube inside the unit for an easier attachment to the reduction and outlet. - The result was that a) The 3 inch flex tube created an excessively long tube.. so I had to first try and cut it, then remove it altogether. b) The now direct connection between the metallic tube and the reduction... they were exactly 3 inch in diameter with no flexibility to go one inside the other.. discovered that the same was true for the 4 inches side to the outlet .. they were exactly the same diameter.. no way to insert one in the other. I had to make cuts in the both sided of the reduction in order to squeeze one side into the metal tube and the other in the unit's vent. - Then taped the heck out of the junctions that were created. - I agree that duct tape, with time, fails and eventually starts leaking.. . The first two attempts to connect with the flex tube I used duct tape and foil tape on top.. the third and last one.. I was too tired to do the double taping and went with the duct tape only.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Glad to be of help and thanks for the additional info!:)

  • @peter-hr1gl
    @peter-hr1gl 2 ปีที่แล้ว +2

    I see others mentioned the two items I saw regarding the need to put a mechanical fastener (either zip tie or hose clamp) on the inside sleeve of the duct to fasten it to fan housing outlet and also to put a plastic or metal sleeve on the electrical wire as it enters the box housing. I also think it would be beneficial to mention that you may have blown insulation around the housing (and most likely will), or have fiberglass insulation around the existing housing). That could fall through as you remove the existing housing and when you cut the whole larger. Could become a real pain/mess (surprised you had no insulation unless you have a second level and therefore were cutting into the dead space between your first and second floors).
    Dealing with falling insulation makes this job much more difficult and does suggest that 'if' you can get to the housing from above to at least move the insulation away from the existing housing, that should be done first (even if you don't want to work from up above).
    The last thing I thought of is that you put two screws into the stud closest to the side of the new housing, but I assume the stud was not close enough on the other side. Putting screws into the new housing to attach to existing studs can be problematic if they are not in the right position and you may need to jerry-rig something in that regard (worth mentioning as a possibility).
    I understand you can't account for EVERY possible scenario, but these are a few common things that could have been mentioned.
    Overall a very good and informative video. Thanks.

    • @RealWorld
      @RealWorld  2 ปีที่แล้ว

      thx for the post and good points:). i had a second level and did not have insulation to deal with.

  • @kashif254
    @kashif254 7 ปีที่แล้ว +5

    excellent video. this is exactly what i was looking for many months as my existing exaust housing is small and i did not know how to put a big housing exaust. thanks so much again.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      thanks for the post and glad to be of help!:) I was in a similar situation ... my fan was too small for the room in my opinion. After replacing the fan, I see little to no moisture issues from the shower ... moisture to some extent is expected immediately following a hot shower, but removing the moisture quickly after is the goal:).

  • @MrMoonpie001
    @MrMoonpie001 7 ปีที่แล้ว +2

    Again, thank you for your time and effort! You have great production skills and much empathy for those of us who are two of five stars when it comes to home repairs like myself! I tell people all the time, I am so lacking in skills that if the project is a four- star it means, someone will get injured if it is a five-star project, it could result in a hospital stay or death!!! LOL!!! One thing you really do well is explaining in advance, the problems one could fall into when doing a home project. Many a hole in the wall I have lacking this forsight! Many folks explain how to do things on the internet, but few tell you what problems and how to overcome them as part of the planning! Keep teaching and I will keep learning!
    Thanks againRich

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      Thanks for the post/feedback Rich and glad to be of help!:) I believe in people helping people when possible and the internet/youtube is a great method to share knowledge ... sharing knowledge and experiences is how we grow/learn:).

  • @willliamthompson9526
    @willliamthompson9526 7 ปีที่แล้ว

    I appreciate your methodical breakdown on replacing the bathroom exhaust fan. Your research on what type of fan to get and why was very helpful. Also, The how to portion on replacing an existing fan was extremely helpful. thank you

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      Thank you for the post/feedback and glad to be of help!:)

  • @starrywarz
    @starrywarz 4 ปีที่แล้ว +2

    I had the exact same (actually probably slightly older) fan as in this video, You can take the cover off, figure out what model your fan is and they sell new fan kits that can replace within the same housing. I did that since my house is older and I have a lot of blown in insulation above which would've gotten messy. But for $45, I was able to get an upgrade fan that fit in the same housing, installed it in 15 minutes, it had 1.5x CFM output and 2x as quiet (half as loud? 2 sones vs 4 sones). It also came with an updated cover, so the fan looks, sounds, and feels like a brand new installation!

    • @Lesikaification
      @Lesikaification 3 ปีที่แล้ว

      WILoveTrains Would you mind sharing a link? I have a Broan 50 CFM and it doesn't wick the moisture much at all. I would like to upgrade just the motor and fan not the entire thing but wasn't able to find an exact replacement with higher CFM. Please let me know where you purchased your replacement and what CFM does it have? Thank you!

    • @starrywarz
      @starrywarz 3 ปีที่แล้ว

      @@Lesikaification do you know the model number of your fan? If so you can search on Home Depot for Broan Xxxx upgrade kit

    • @Lesikaification
      @Lesikaification 3 ปีที่แล้ว

      @@starrywarz yes it's a Broan 688-k but all I could find so far was the same 50 CFM replacement.

    • @starrywarz
      @starrywarz 3 ปีที่แล้ว

      @@Lesikaification search for 205964212 on Home Depot website. That should take you to the upgrade kit which is listed for 688 in description!

    • @starrywarz
      @starrywarz 3 ปีที่แล้ว

      @@Lesikaification if you need something with more CFMS, aka a larger fan you’ll likely have to buy a new fan and cut a larger hole in the ceiling etc. but for a quick upgrade this is easy and worked for me

  • @ahmadawadallah5321
    @ahmadawadallah5321 ปีที่แล้ว +1

    This was an excellent vid. I needed to remove my fan housing but I couldn't see any screws. It's probably stapled in as yours was. Thank you.

    • @RealWorld
      @RealWorld  ปีที่แล้ว +1

      Glad to be of help!:) My new(er) fan is running strong and working well!

  • @samkim2766
    @samkim2766 2 ปีที่แล้ว +1

    It's so helpful video instruction for installation of Bathroom Fan.
    Thank you!

  • @klgraf
    @klgraf 11 หลายเดือนก่อน +1

    Thanks for showing the removal and retrofit of new fan. Appreciate it!

    • @RealWorld
      @RealWorld  9 หลายเดือนก่อน

      glad to be of help!:)

  • @michialmiller1754
    @michialmiller1754 4 ปีที่แล้ว +11

    Good gravy, bless this man's heart !!!!

  • @romulomusta
    @romulomusta ปีที่แล้ว

    By far the best video for someone who needs to replace their bathroom fan, thanks a lot!

  • @mariuszdabrowski7662
    @mariuszdabrowski7662 2 ปีที่แล้ว +1

    Indeed according to the size of the bathroom that's where you need the space underneath the door He's advanced in the room

  • @Craigpv2d
    @Craigpv2d 3 ปีที่แล้ว +1

    Nice video. Just a few tips I might pass along. First, as others have said, a romex connector should be used or at least a plastic bushing. Second, Duck tape doesn't last forever, especially if it is the cheap stuff. Where I live in Wisconsin, the current code recommends a mechanical fastener AND HVAC metal foil tape which lasts much longer. So for a mechanical fastener you could use a high quality zip tie, some sheet metal screws where the head catches the wire in the hose, or a metallic hose clamp. I recently had new shingles installed and took the opportunity to install roof mounted 4" vents above all three fart fans in my home. About 8 feet directly above the fans. The existing fart fans exited over 20 feet away through the vertical face of the gables and used uninsulated 3" aluminum flex dryer hose. Two of the three runs have holes in them and also water in the low spots. Now I have 4" insulted vent hose that is only 8 feet long. Even with the existing fans, ventilation is much better and the noise is less as well. We also have eliminated our ice dam problems which we still had even with the new shingles. Most of the hot, damp air from the fart fans was exiting into the attic space. Interestingly enough, the 2 stovetop hood fans, (our place is a two family duplex), were directly vented vertically though the roof with insulated tin HVAC ducting. I don't know why they skimped on the fart fans.

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Appreciate your post/feedback!:) This is great information and making me wish I could pin two comments to the top:). I pinned the romex connector early on but you have more to offer in your post. TY.

  • @stackedhippiechick
    @stackedhippiechick 6 ปีที่แล้ว +2

    I installed one in my bathroom and it works great. I have a 1-inch door clearance. However, the Broan InVent 110 should use a 4in duct to operate as designed. Only use the 4 to 3 reducer if you don't have access to the attic. The Broan Invent bathfan is the best fan to retrofit your bathroom.

    • @y_o_oj754
      @y_o_oj754 3 ปีที่แล้ว

      Youre good

  • @PapaStrumfPS3
    @PapaStrumfPS3 4 ปีที่แล้ว +2

    I can't find video that is bad or uninteresting. Real role model. Can we get update on this, did new vent help moisture situation ?

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      thanks for the post/question:). yes, this worked for me as the air flow has improved. i will also add that we leave the door over and the fan on after the shower for 5-10 mins.

    • @PapaStrumfPS3
      @PapaStrumfPS3 4 ปีที่แล้ว +1

      @@RealWorld Thanks for answer. I just moved to new apartment and seems like we have same problem so I might give it a go :)

  • @e3a3c3
    @e3a3c3 4 ปีที่แล้ว +1

    I put 2 exhaust fans in my shower room, on a timer, when I built my house in 1983. Turn it on after showering. Does the job fast, but gotta crack the bathroom door to let in enough air. Clears the mirror fog fast too.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      Thanks for the post/feedback:).

  • @radchander
    @radchander 3 ปีที่แล้ว +1

    Very clear tutorial. Not to be picky, but I didn’t see a connector or wire clamp when the power supply entered the housing through the feed hole. Did I miss it. Thank you

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Glad to be of help:). I did not show in the video but you should use a wire clamp where the wires enter the housing.

  • @televisionplayer3990
    @televisionplayer3990 7 ปีที่แล้ว +1

    Firstly, Fantastic video. Unlike another gentleman, who said it's beyond his ability to follow this, I'm very handy, and I will 100% be upgrading my fan myself using the training I received from your video. One question that always stumps me on electrical jobs: Where do I connect the green ground wire? You just said "coil it" ... but where do I screw it onto? I usually screw it onto the metal casing with the ground-screw attached to the casing. But I didn't see you attach it anywhere. Thanks for the response.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +1

      Thanks for the post/feedback and glad to be of help!:) The green is used for ground and should attached to the bare copper wire coming from the wire group (white, black, copper). Sometimes you may see a green screw the housing or casing, and this can be used as well.

    • @televisionplayer3990
      @televisionplayer3990 7 ปีที่แล้ว +1

      Ok Thanks !! I will definitely be commenting this week as to how my installation goes. Thank you so much again !!

  • @redline870
    @redline870 7 ปีที่แล้ว +31

    I think code requires the use of a Romex clamp where the wires enter the box. I’d annotate the video and add that point in there, it’s very unsafe to go without one.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +1

      Great point and thank you for the post!:) I will post an add note in the description and see if I can overlay that part of the video with a notation on the clamp as well.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +1

      Just discovered that TH-cam removed the free form annotation feature - ouch:). I will pin a related comment to the top and add a note in the description:).

    • @bguen1234
      @bguen1234 5 ปีที่แล้ว

      How is it "very unsafe"?

    • @Guillotines_For_Globalists
      @Guillotines_For_Globalists 5 ปีที่แล้ว +7

      @@bguen1234 Years of vibration can cause the wire to get a cut in it from the sharp sheet metal fan box. The clamp acts as a grommet to protect the wire's insulation.

    • @bguen1234
      @bguen1234 5 ปีที่แล้ว

      @@Guillotines_For_Globalists Yeah, so not "very unsafe" or even very likely. But a simple plastic grommet is probably a good idea.

  • @garyboyce6186
    @garyboyce6186 2 ปีที่แล้ว +1

    Thank you this was fantastic, I’m confident the power was off at the switch and wouldn’t be doing that in the dark was the only thing I noticed. Otherwise this is what I’ll be doing. Hoping mine is easier as it’s changing a Broan for another brown but more powerful

    • @RealWorld
      @RealWorld  2 ปีที่แล้ว

      thanks for the post gary and hopefully your project went/goes well! :)

  • @aaronclayson2813
    @aaronclayson2813 6 ปีที่แล้ว +1

    Thank you for this video, you've given me the courage to replace my bathroom fan! I'm buying a slightly different one, but I think the basics should still be close enough!

    • @RealWorld
      @RealWorld  6 ปีที่แล้ว

      Glad to be of help!:) If I can do it, you can to!:)

  • @scoop4321
    @scoop4321 4 ปีที่แล้ว +1

    I am upgrading my bathroom fan, and I am installing the same one you used. I thought I would check my venting tube which runs horizontally about 20 feet to the side of my house. I removed my outside vent, and I found bird nests in there. I cleaned it out, and it filled up a bucket. So I would suggest you check that venting to be sure it is clear of debris.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      That is AWESOME!:) Great find/tip:). Birds will nest in the oddest place.

  • @sansfreewill3843
    @sansfreewill3843 2 ปีที่แล้ว +1

    Very thorough walk through, and clear and concise narration. Thank you! and Subscribed.

    • @RealWorld
      @RealWorld  2 ปีที่แล้ว

      ty and welcome to the channel! :)

  • @aerodicus
    @aerodicus 7 ปีที่แล้ว +65

    What I can't figure out is people that refuse to turn the fan on when they crap, do they like the smell?? I think I'm going to wire the lights and fan together on a timer so there's no way around it.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +3

      lol - good point and i like the idea!:)

    • @Billy_Darley
      @Billy_Darley 7 ปีที่แล้ว +14

      i like the noise too. privacy. :)

    • @Jeff-xy7fv
      @Jeff-xy7fv 7 ปีที่แล้ว +15

      Flush the toilet as soon as the crap hits it. Problem solved!

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +4

      LOL - yes, that is another solution!:)

    • @Jamestfarrell
      @Jamestfarrell 6 ปีที่แล้ว +19

      Had the same problem. I just wired the toilet seat so that when a toilet user sits down the 110 volts gets switched from the toilet seat to the fan. Only had a couple of bugs to work out but my attorney says he's taking care of that.

  • @JamesThompson-xl4yu
    @JamesThompson-xl4yu 3 ปีที่แล้ว +2

    Should have use a clamp for the duct as tape is not a mechanical but a sealer for air flow being fans vibrate. I saw the box had rolled edge where the wire came in so may be ok, but agree a clamp on the wire is better. Thanks for the video, you did a good job overall. I think these fans need a humidity sensor that runs the fan till the humidity drops to normal level.

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Thanks for your post/feedback and agreed ... a clamp would be a good idea:).

  • @digdug5945
    @digdug5945 4 ปีที่แล้ว +7

    You are going to have a fire in that unit later on down the road because you didn't use a romex connector. The unit will eventually cut through the romex and possibly cause a fire. You need to pull that unit down and correct that mistake.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      LOL - 1) this is NOT a high vibration unit 2) i pinned a comment to place to romex connector in the box for anyone with concerns as i feel it is prudent to include it

  • @bobprins2324
    @bobprins2324 2 ปีที่แล้ว

    My question is how much good does it do to try push more cfms thru a 3" vent ? The Fan is designed for 4" and you're reducing/restricting the flow. That's defeeting the purpose of the replacement ! In my 40+years of working in New home construction as a plumber, I've never seen an electrical use a reducer.
    I realize it's more of a job to do it right, but thats my plan, even if I have to convert to a roof vent or pull a 4"thru with the old 3"
    Also if the wall switch or timer is off, there's no need to work in the dark ! Also replacing a switch with a timer is much better. It allows you to crank the timer to the max as you leave to maximize run time to vent even more humidity.
    We keep our master suite cooler which causes more condensation so it's time for an upgrade.

  • @bassetHoynd
    @bassetHoynd 3 ปีที่แล้ว +2

    Thank you for the great video. You have really explained some of the smaller details I had questions about.

  • @paulmoffat9306
    @paulmoffat9306 5 ปีที่แล้ว +2

    One 'rule of thumb' is that the minimum CFM required is = to the square footage of the room, so a bathroom of 60 sqft, would need a 60 cfm fan. Also, you can buy fans that are almost silent today, and still have the CFM needed, but you pay more for quietness.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Thanks for the post and good point Paul:). I would stress the word 'minimum' as more might be desired to really move the air. I also thought about the quiet factor but realized most people may want a louder fan to mask ... uhhhhh ... various sounds:).

    • @jackson2620
      @jackson2620 5 ปีที่แล้ว +1

      ahaha i'm guilty of the fan mask myself. works like a charm

  • @MarkTellier
    @MarkTellier 5 ปีที่แล้ว +2

    This is a problem we have had in our bathroom for quite some time. Thanks to your video, I am now able to fix the problem.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Glad to be of help and best of luck!:)

  • @richardlorith8256
    @richardlorith8256 3 ปีที่แล้ว +1

    Thank you for the video, maybe something I need to look at in my bathroom, that needs replacing, get wet spots above my shower

  • @kevinbelluche1747
    @kevinbelluche1747 5 ปีที่แล้ว +2

    Great video ,I currently have the same problem you had, the calculation you provided will be a huge help!

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Glad to be of help Kevin!:) Still working strong today!:)

  • @barrynirmal
    @barrynirmal 5 ปีที่แล้ว +1

    Very good video. Because it is detailed it shows all aspects of the job. I did not have to remove the housing but if I have to, I can do it with help from this video.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Thanks for the post Barry and glad to be of help!:)

  • @sambaritone
    @sambaritone 7 ปีที่แล้ว

    Great video, thank you very much. I need to do exactly the same thing in my bathroom, and the attic space is so remote and tight, there's no practical way for me to get in there to do it the standard way. My old one never really worked well, and I took it apart to realize that the fan motor either runs backward, or the impeller is made for the opposite direction. It actually moves very little air, because of this. So, I'm going to get one of the same ones you installed, and get it done. Thank you again, this video was extremely helpful, especially your detailed explanations and up close video.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      Thanks for the post/feedback and glad to be of help!:) No fun when the bathroom walls are wet and start to streak, etc. When I saw this happen in my bathroom, it was time to take action:).

    • @sambaritone
      @sambaritone 7 ปีที่แล้ว

      RealWorld well, I got it done yesterday afternoon. I had to wrestle with the exhaust port and hose adaptor, but it was a lot easier after watching your step by step directions. Thanks again.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      Great to hear and glad to be of help!:) Remember to leave the fan on a bit after each shower in order to clear the room ... the larger fan should handle the job:).

  • @MegaHollywood1971
    @MegaHollywood1971 2 ปีที่แล้ว +1

    I'm super late to this video, but this was superb instruction! Calm, Cool, and Collected - Well Done 👍

    • @RealWorld
      @RealWorld  2 ปีที่แล้ว

      thank you! :)

  • @enriquegonzalez2540
    @enriquegonzalez2540 6 ปีที่แล้ว +2

    When buying paint for bathroom let the paint department what you are painting.At Home Depot you can add a additive for about five bucks that when mixed with the paint it will greatly
    reduce those black spots due to moisture,but adding the fan with more cfm is a necessity .

    • @RealWorld
      @RealWorld  6 ปีที่แล้ว

      Great idea regarding the paint:).

  • @number1pappy
    @number1pappy 5 ปีที่แล้ว +8

    Awesome video! Thank you! I feel confident to do this to my bathroom now!

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว +1

      Glad to be of help ... If I can do it, so can you!:)

    • @aLortizable
      @aLortizable 3 ปีที่แล้ว +1

      Just use a Rome clamp to do it right.

  • @Tchairdjian
    @Tchairdjian 5 ปีที่แล้ว +2

    Exactly what I needed! Thanks for the details for amateurs like me. Mine was built in 1999 too and the motor sounded seized, which woke the dead up every time anyone used it. LOL

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว +3

      LOL - glad to be of help and I know the sound!:)

  • @wuntunmein88
    @wuntunmein88 3 ปีที่แล้ว +1

    You made it look easy. Thanks for posting a detailed and easy to follow video

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Glad to be of help!:)

  • @busymama2402
    @busymama2402 7 ปีที่แล้ว +4

    Great video! Did you ever update if the 110 cfm was enough for the small bath? Having tons of moisture in our small bath and needing to upgrade fan and would love to know. Thx!

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +4

      Thanks for the post/feedback!:) Yes, the new 110 cfm was the answer and appears to be working great!:) We have also been more diligent about leaving the fan on after showing for at least 5-10 mins with the door open.

  • @SupermanChad23
    @SupermanChad23 3 ปีที่แล้ว +1

    Reducing your exhaust diameter I have found will make the unit work harder so I'm glad you had a 4-inch exhaust. I would not recommend anyone tapering down if the fan is requiring a certain diameter You're only going to make the unit work that much harder. If you wanted to be extremely safe while you worked also you could pull out the switch off the wall and disconnect it there and cap that so that you could turn the lights back on and definitely not worried that you have any power up at the exhaust fan and then just reattach the switch when you're done. Why wouldn't you secure it with the holes on the flashing?? Also never use duct tape in an area like that when that duct tape dry rots as it will it's going to let loose I would have used metal tape, that stuff will never degrade. Also some covers are larger and you sometimes need to make sure that you're going to have clearance you are pretty close there to that corner I would have measured how much overlap that was going to take and mention that in the video but you got lucky.

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Good point Chad and thx for the post. The fan will work a bit harder but will still work. It's like exhaling with your mouth open and doing the same with your lips place together forming a small hole (like whistling). the same amount of air will flow out, but you will need to push a bit more when whistling.

  • @Ducknell
    @Ducknell 3 ปีที่แล้ว +1

    Your video gave me confidence to tackle this task. I installed same fan.3 hours later and bunch of cuss words shouted complete. Fan makes almost a rattle sound. Pull it out of housing quiet? Thinking is noise from having to use reducer? I don't know. Nothing loose to rattle. Works good but sounds like old crappy fan. Frustrated. Even removed plastic dampener to see if different. It's not. Again it's quiet when on but out of housing. Any ideas?

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว +1

      Hmmmm the reducer should not impact noise. Nonetheless, my fan is not ultra quiet either which is okay as some noise is to be expected given the larger motor, higher volume, etc. I will trade off a bit more noise for greater air flow:).

    • @Ducknell
      @Ducknell 3 ปีที่แล้ว +1

      @@RealWorld yes I get it I'm not being picky about the volume of noise just that it sounds not like a steady hum but like something is loose. Thanks for responding.

  • @joeretired4552
    @joeretired4552 3 ปีที่แล้ว +1

    About the cubic feet of the room - someone has already pointed out the room is 405 ft cu. The fan is too small to remove the moisture quickly enough. Did you increase the fan size based upon that size room????

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Yes, I realized the same:). While the smaller fan is better than no fan, a larger fan is more appropriate for the given room size.

  • @a.f.carmona3484
    @a.f.carmona3484 3 ปีที่แล้ว +1

    Thanks for video - gonna be upgrading my 50cfm to the same model you used. 🤙🏽

  • @TW-il4vy
    @TW-il4vy 4 ปีที่แล้ว +2

    The real question is where the end of the fan duct terminated since your old fan was actually working. I found out my bathroom fan ducts all went to vented soffit and simply dangled on top by lazy builder/contractors, and not actually vented to the outside correctly through the side walls nor the roof. Check your outdoor vent if you can find it.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      You make a good point ... check the route of air flow to ensure nothing is off or blocked as this might be the root cause.

    • @kathryndegraaf7115
      @kathryndegraaf7115 4 ปีที่แล้ว +1

      Any suggestions as to how to find it? Is there a way to trace venting??

    • @TW-il4vy
      @TW-il4vy 4 ปีที่แล้ว +1

      @@kathryndegraaf7115 You'll need the access to the attic or the opposite side of the wall where the fan is installed to find where the connected duct leads out to.

  • @JessicaT-qp9uv
    @JessicaT-qp9uv 2 หลายเดือนก่อน +1

    I'm necroing this thing but heres info to help installers. Mark your drywall and remove the appropriate amount prior to removing the housing. Then you can easily remove it as the sheetrock will be out of your way.

  • @supersaiyangoku3580
    @supersaiyangoku3580 5 ปีที่แล้ว +81

    Are you John Cena's brother?

    • @michaelleddy3701
      @michaelleddy3701 4 ปีที่แล้ว +6

      Hahaah 1st thing I thought when the video started.

    • @cwickwitted
      @cwickwitted 4 ปีที่แล้ว +3

      @@michaelleddy3701 me too, brother

    • @JonO387
      @JonO387 4 ปีที่แล้ว

      Don't insult the guy. Come on.

    • @phrebh
      @phrebh 3 ปีที่แล้ว

      @@JonO387 John Cena has done more the Make-a-Wish foundation than any other celebrity.

    • @JonO387
      @JonO387 3 ปีที่แล้ว +2

      @@phrebh OK?

  • @lovefeist3136
    @lovefeist3136 4 ปีที่แล้ว +1

    Excellent. Very detailed. Thank you! A Sawzall with a short hacksaw blade would have made quick work of that staple. Or a simple "frameless" hacksaw designed for tight spaces.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      Thanks for the post and agreed - a sawzall would have been nice:).

  • @stevied9082
    @stevied9082 7 ปีที่แล้ว +2

    What a great vid. Having the same problems with my small bathroom & the exhaust fan is only 50cfm. I'm gonna go ahead & upgrade to a higher cfm & use your video as a guide. Thank you much brother.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +2

      Thanks for the post/feedback and glad to be of help!:) The moisture control in my bathroom is much better since installing the new fan:).

    • @stevied9082
      @stevied9082 6 ปีที่แล้ว

      Installing my exhaust fan... as I get to the wires, there is a black & white in ceiling, but no copper for the ground wire.... is that a problem????

    • @RealWorld
      @RealWorld  6 ปีที่แล้ว +2

      Typically electrical wiring should have 3 wires (black, white, and copper). The copper is used for ground. The fan will run without a copper ground but this creates a safety issue if a ground is needed for any reason (i.e. lightening strike, etc.).

    • @stevied9082
      @stevied9082 6 ปีที่แล้ว +1

      RealWorld thank you much for your response & knowledge.
      God Bless you brother.

    • @RealWorld
      @RealWorld  6 ปีที่แล้ว +2

      Glad to be of help and may God bless you and your family!:)

  • @JasonSmith-qx3zh
    @JasonSmith-qx3zh ปีที่แล้ว

    Looking forward to an update. Thanks for all you do.

  • @MrMackanno
    @MrMackanno 4 ปีที่แล้ว +1

    If moisture on walls appeared after the reno, even after leaving the fan on for 20 minutes means he didn't use bathroom rated paint. Seems silly BUT bathroom-rated paint exists for a reason, it has chemicals that help avoid moisture from being absorbed.
    You can also paint the bathroom with semi-gloss or glossy paint, just keep in mind these paints require more attention when applying them because the overlaying of the roll is more pronounced if you are not applying the same amount of paint all over the surface.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      Thanks for the post/feedback and you make a good point:). Consider bathroom rated paint which will help.

  • @mikeimparato824
    @mikeimparato824 6 ปีที่แล้ว +3

    At 25:39 he needs to install a type NM cable connector in the wire entry hole per NEC code.
    This to prevent any chafing of the conductor insulation that will over time cause a ground fault, short circuit or potential electrical fire hazard.

    • @RealWorld
      @RealWorld  6 ปีที่แล้ว

      Thanks for the feedback Mike!:) Agreed.

  • @arturobolanos6061
    @arturobolanos6061 4 ปีที่แล้ว +2

    I have the same problem but worse. I have a son that spends an hour taking a shower I repainted and the mold came back. I am going to install larger fan and uses kilz primer and use semigloss paint

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      lol - you are on the right path ... i did the same - although i believe i used primer and satin instead of semi-gloss (i believe satin is one step down from semi-gloss regarding sheen):).

  • @Topazpm20
    @Topazpm20 3 ปีที่แล้ว +1

    Great video.. I have been meaning to do this for a long time, but am afraid of dealing with the attic insulation above the ceiling drywall. Please tell me if the fan housing is separated from the insulation or if it sits right against it. Thanks in advance

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Glad to be of help!:) I have a second floor above and had no isolation between floors. Nonetheless, I have a shower on the second floor as well which does have an attic above and yes, the isolation will rest on top of the fan:). It might be a bit messy but very doable.

  • @notawildthingy
    @notawildthingy 4 ปีที่แล้ว +1

    how did this work out? noticed that you used a reducer to get to your 3" exhaust pipe. Conventional wisdom states that high airflow systems are more influenced by pipe size than fan size. In other words, if you need to move more air increase the pipe size.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      Still working strong ... no problems and definitely helped the situation:). The reducer is not significant enough to adversely impact the air flow with the given volume.

    • @notawildthingy
      @notawildthingy 4 ปีที่แล้ว +1

      Cool, I'll be in the same situation shortly, so thanks for sharing.

  • @danaolson2871
    @danaolson2871 4 ปีที่แล้ว +2

    #1. Until you clean the lint that is blocking screen out at the vent exit, the fan airflow will not be great. Every bathroom fan in the USA has a outlet with louvers and a wire screen that can't be easily removed. I had to snake 12 feet of shop vac hose to reach the screen in my duct outlet. Then the fan worked great for the first time since I owned the house. Next time I will try blowing the lint back down the duct to see if that is easier. #2. Use a squeegee to get most of the water off the shower walls into the drain and the place dries out much faster.

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      Thanks for the post/feedback Dana!:) Great tip on the vent exit! I had the same on my dryer vent but not certain about the shower vent ... time to take a closer look:).

  • @suedankrell425
    @suedankrell425 5 ปีที่แล้ว +1

    Hi. Thanks for video and helpful instructions.
    Please do yourself and everyone else a favor and wear eye protection, particularly looking up into sheetrock work and fiberglass. As a doctor, I'm tired of taking chunks and stuff out of people's eyes, only to hear them say, "Well, I guess I shudda." True story: I had one guy come in for his second eye injury, exactly like the first, a year later to the week. Hit by a chip of fresh cedar that I had to remove; had abrasion of the eye and chemical conjunctivitis from the cedar oils. Never came back, and I'm not sure if it was because of the crap I gave him or he started using safety goggles.
    Keep up the good work.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      LOL - absolutely and THANK YOU for the post/tip!:) I know a few people who trapped various particles in their eyes. You make a great point which is much appreciated.

  • @kimnuyen4628
    @kimnuyen4628 4 ปีที่แล้ว +1

    Excessive CFM is nullified by the 4" to 3* reducer. (Bad idea). Go to the manufacturers website for proper installation. Also dimmable lights ,humidity sensors, variable fan speeds all require special switches on the wall. Upgrades may require more than you think.

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      reducers are fine depending on the volume

  • @ntt2232
    @ntt2232 3 ปีที่แล้ว +1

    I had exact same problem and replaced my fan and it immediately took care of the problem.

  • @francisantony12
    @francisantony12 6 ปีที่แล้ว +6

    Super Useful Video. Thank you for taking time.

  • @onlimi616
    @onlimi616 4 ปีที่แล้ว

    Great video! Makes a job that I've been terrified of look very simple. One question on the electricals, you don't need to connect the ground to the metal housing? It's ok to leave it more or less just dangling inside?

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว

      Thanks for the post/question:). You do not want to leave the ground unattached ... the ground should be attached to a ground wire of some sort (the wire may run back to a ground or might be a pig tail running from the housing).

  • @siku5it
    @siku5it 5 ปีที่แล้ว +1

    Regarding the suggested timer - it's very tempting but it requires a "neutral" (4th wire) which does not exist in older houses wiring. - Maybe there is a 3 wires model out there that I could use.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      Good point and I would need to check into this further (3 vs 4 wire).

  • @camaromike82
    @camaromike82 7 ปีที่แล้ว +9

    Be careful working on a switched device with only the switch being off as your protection. Depending on how it was installed it may be opening / closing the neutral not the hot conductor. If you happen to touch bare hot and a grounded object, ZAP.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      Good call Mike!:) I believe in tripping the breaker.

    • @Billy_Darley
      @Billy_Darley 7 ปีที่แล้ว +5

      i got zapped once changing out a 120v outlet. in one hand and out the other. sounded like the rhythm of a jackhammer in my ears but not as loud. hurt like hell on my hands and wrists lil bit of pain thru my arms, chest and back. i had to fall back in order to release myself from it. couldnt force my hands open. im surprised im still alive to tell about it. now i never fail to kill the breakers first :)

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      Wow - sounds like you were lucky:). I had an electrician friend get zapped on more than one occasion - not a good feeling:).

  • @rickghigna6986
    @rickghigna6986 7 ปีที่แล้ว +1

    I can do many DYI. But for the middle of the road person, up on a ladder doing this job is on the difficult side. What is it worth in YOUR time. If you have the experience, go for it. Most of us this is not an easy project. Thanks.Rick

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว

      Hi Rick and thanks for the post/feedback:). The task can be a bit daunting but doable depending on the situation.

  • @stevencogar7393
    @stevencogar7393 3 ปีที่แล้ว +1

    Thank you for getting back to me . Enjoyed your Video

    • @RealWorld
      @RealWorld  3 ปีที่แล้ว

      Glad to be of help Steven:). I typically post videos about photography but also conduct a good amount of everyday repairs:).

  • @g8738
    @g8738 ปีที่แล้ว

    Thank you for the video !
    My fan at washroom broken loooong time 😢
    I’ll try to fix it !!!!

  • @derrickhallrealty
    @derrickhallrealty 7 หลายเดือนก่อน +1

    Thank you, this will help me to tackle this job on my own

    • @RealWorld
      @RealWorld  4 หลายเดือนก่อน

      glad to be of help!:)

  • @oscarbalderas6025
    @oscarbalderas6025 5 ปีที่แล้ว +4

    Thank you, great video tutorial, I was looking for this information and you explained it very clearly.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว +1

      Glad to be of help Oscar!:)

  • @martynenkodima
    @martynenkodima 10 หลายเดือนก่อน +1

    How did you connect the vent housing in the attic to the box in such a narrow place? Looks impossible

    • @RealWorld
      @RealWorld  9 หลายเดือนก่อน

      it was previously laid with the build of the house so i did not have to make a new run - thankfully!:)

  • @50tigres79
    @50tigres79 5 ปีที่แล้ว +3

    Why did you only secure one side of the housing with 2 decking screws? the other side looks kind of loose.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว

      The two screws did the trick and seems to hold well - no need for any additional screws in my opinion:).

    •  3 ปีที่แล้ว

      @@RealWorld Actualky, You should definitely worry about only using two deck screws as it is loose and vibrating even more than normal. Considering you didn’t use an electrical grommet, that amount of vibration on the wire is a fire hazard just waiting to happen. Other than these two issues,your video was good for the beginner DIY’er.

  • @mav48185
    @mav48185 4 ปีที่แล้ว +3

    How well is that holding when it’s just in one joist like that? I’m a beginner here and confused if that puts stress on anything with the weight of the motor

    • @RealWorld
      @RealWorld  4 ปีที่แล้ว +1

      great question and one that i might ask as well:). it's solid ... the sheet frame is relatively firm/rigid and will hold with only one side securely fastened.

    • @The777fo
      @The777fo 4 ปีที่แล้ว +1

      See the post above from Mike Imparato that addresses this concern with a great remedy!

  • @jerzyserafin3855
    @jerzyserafin3855 ปีที่แล้ว

    Excellent, very comprehensive video. Thank you.

  • @monsteramn88
    @monsteramn88 7 ปีที่แล้ว +1

    thanks for the video, I've been trying to wrap my head around how to make this remodel fan without destroying the old housing. it seems more beneficial to completely redo the whole thing.

    • @RealWorld
      @RealWorld  7 ปีที่แล้ว +1

      Thanks for the post ... hang in there:).

  • @billdowney6891
    @billdowney6891 5 ปีที่แล้ว +27

    Should have used insulated foil tape instead of crappy duct tape. That tape will fail and you'll have air leaks.

    • @RealWorld
      @RealWorld  5 ปีที่แล้ว +3

      Thought about doing the same and for the same reason:). Nonetheless, the duct tape is still holding without any signs of wear as of today:).

    • @mdillon4311
      @mdillon4311 5 ปีที่แล้ว

      I learned that too when I put up my vent hood of my oven. Glad I'm not the only one paying attention to that detail!

    • @billdowney6891
      @billdowney6891 5 ปีที่แล้ว +7

      @@mdillon4311 It's very important to make sure the duct work is insulated and all seams are taped properly with insulated foil tape or you will experience condensation leaks. I'm a maintenance tech at an apartment complex and we just dealt with a repair that was a result of improperly installed duct.

    • @rafars2246
      @rafars2246 4 ปีที่แล้ว

      foil tape doesn't insulate...

    • @glasser2819
      @glasser2819 4 ปีที่แล้ว +1

      everything is easily messed up!! There are rules even for proper venting ducts.
      Nothing BUT a solid steel duct for fire rating!!
      Insulated for winter condensation build up
      Vented outside not in attic space...
      Seams saled with mastic so you don't smell the dirty attic air when running kitchen hood (sucking air out from anywhere possible)
      Screws are mechanical fasteners, duck tape is not... even the real aluminum one. Screw all duct connections.

  • @DerkaDerka66
    @DerkaDerka66 ปีที่แล้ว +1

    Any advice on how to remove the fan once it’s installed? I need to replace mine and I’ve removed the two screws on each side but it still seems secure up in the housing and I don’t want to break anything trying to pull it down

    • @RealWorld
      @RealWorld  ปีที่แล้ว

      you may need to leverage a prybar as i suspect the housing is nailed to the stud

  • @markmarquez5431
    @markmarquez5431 ปีที่แล้ว

    I am not in construction business so inam learning here. But why multiply the area with only 1.2 for 9ft ceiling? Isn’t is supposed to be L x W x H so your 45 sq-ft will give you approx 405 cu-ft of space. So your 50cfm fan will be able to get rid of 405 cu-ft of air in the bathroom in 8mins. But not all moist air will get exhausted in 8mins. It will gradually decrease overtime that is why it is better to leave the fan running a little longer.