    In this video, we take a look at how to test a pool pump motor capacitor with a multi-meter. If your pool pump motor makes a humming sound when you try to turn it on, then following these steps can help you determine if you need a new capacitor or a new motor.
    SUBSCRIBE for FREE swimming pool care and maintenance videos
    every week: bit.ly/SubscribeINYO ****
    VISIT our blog for weekly swimming pool tips, tricks, and more! bit.ly/InyoBlog
    SHOP at our online store! bit.ly/InyoPools
    LIKE us on FACEBOOK! / inyopools
    FOLLOW us on TWITTER! / inyopools
    FOLLOW us on INSTAGRAM! / inyopools

ความคิดเห็น • 27

  • @StepUnclesStepCousin
    @StepUnclesStepCousin 2 ปีที่แล้ว +2

    I’m a pool tech and see this issue all the time. I will get a volt meter that can test capacitors. Very helpful. Thanks!

    • @Inyopools
      @Inyopools  2 ปีที่แล้ว

      Glad it helped!

  • @donhorvat1931
    @donhorvat1931 10 หลายเดือนก่อน +1

    😀Thank you, you guys rock. Motor (~$600), the capacitor was $14 and available locally. (5 minutes 2 screws) I would have ordered it from INYO, but time was important in the case.

    • @Inyopools
      @Inyopools  10 หลายเดือนก่อน

      The best kind of money is saved money. #Facts 😃

  • @poolmotorrepairguyFL
    @poolmotorrepairguyFL 2 ปีที่แล้ว +2

    Jay the Florida pool pump motor bearing repair guy When Service Calls Longwood approved ! that was good info 👨‍🔧IPool

  • @ronaldedwards2465
    @ronaldedwards2465 11 หลายเดือนก่อน

    Good video
    Thank-you

  • @freddurst4420
    @freddurst4420 ปีที่แล้ว

    Nice job and great video !!

    • @Inyopools
      @Inyopools  ปีที่แล้ว

      Thank you very much!

  • @harryvon9275
    @harryvon9275 9 วันที่ผ่านมา

    If my capacitor is rated 124-148 and I am getting 152, is that close enough or does it need to be replaced? It does not have a tolerance % printed on body.

  • @keithfadden7316
    @keithfadden7316 ปีที่แล้ว

    I found a flaw that caused the pump to burn. The yellow wire from what I believe is the starter cap caught on the flywheel. Luckily I was standing next to the pump and turned it off in time.
    I repaired it by soldering the wire back and added tie wraps to prevent a repeat.
    I just wanted to make you aware of this because it could happen to any pump and if the tie wraps were added in the factory, it could prevent this. Had I not been there, there would have been a fire.
    I have pictures if you are interested.

  • @mattsarnelli954
    @mattsarnelli954 หลายเดือนก่อน

    Thanks! Definitely a helpful video! Now, I have to see if the capacitance result being higher than the reference range is ok. Mine is 200-240 and the test shows it at 260?? Margin for error, perhaps.. 🤷🏻‍♂️

    • @Inyopools
      @Inyopools  หลายเดือนก่อน

      There might be a +/- 5%; sometimes it is 6% or 10%; that would explain the difference.

  • @bigfish2544
    @bigfish2544 ปีที่แล้ว

    I have the exact capacitor in your video. Its reading 116. So im assuming it needs to be replaced??

    • @Inyopools
      @Inyopools  ปีที่แล้ว

      If your capacitor is rated as 124 - 149 MFD like the one we show, then yes, you would need to replace it. Start Capacitor, 124-149 MFD - BC-124 - www.inyopools.com/Products/07501352014032.htm

  • @MurbyD.HealthTalk-vj3bk
    @MurbyD.HealthTalk-vj3bk 4 หลายเดือนก่อน

    KI have a pump in which the start capacitor emits smoke as soon as I turn the power on. Replaced the capacitor , it does the sma thing. What coul be the cause?

    • @Inyopools
      @Inyopools  4 หลายเดือนก่อน

      Your capacitor seems to be overheating, so I would presume there is an issue with the circuitry. My guess would be something is causing overcurrent. I suggest having a licensed electrician troubleshoot the circuit.

  • @rickchapman2733
    @rickchapman2733 9 หลายเดือนก่อน

    My Pentair pump stopped working and nothing shows on the display either. A tech checked it and said there is power going to the unit so it’s not electrical. Would a bad capacitor cause these symptoms? Thx.

    • @Inyopools
      @Inyopools  9 หลายเดือนก่อน

      When you say "display" are you referring to a IntelliFlo's motor mounted control/timer?

  • @thaddeusjohnson9109
    @thaddeusjohnson9109 ปีที่แล้ว

    My pump is making a kinda loud noise but its working it didn't use to make that noise but water is flowing and the pump running. what's wrong with the pump

    • @Inyopools
      @Inyopools  ปีที่แล้ว +1

      The most common cause would be bearings that are beginning to fail. The motor will continue to get louder until eventually, the shaft seizes up. The bearings can be replaced, if you are handy and have the correct tools. Most pool owners replace the motor once the noise gets too loud.

  • @jackietaylor5165
    @jackietaylor5165 2 หลายเดือนก่อน

    What if there is no humming noise when u turn it on ...pump does not come on... silent

  • @BackpackandGear
    @BackpackandGear ปีที่แล้ว

    I have a well pump that won't start and I purchased a start capacitor that goes on the outside of the motor since the original capacitor tested at 205 micro farads when it should be in the range of 161-193 micro farads. The new capacitor tested at around 194 micro farads. The motor still won't start and just hums. Should the new capacitor be in the range or does it mean that it is bad being outside the range by just 1 micro farad? I was planning soon to open the end of the motor to see what is inside. I did not realize that there could be another capacitor. I just assumed the capacitor on the outside was the start capacitor. Maybe it is not!

    • @commieslayer8218
      @commieslayer8218 ปีที่แล้ว

      I had also not starting motor with run capacitor bad, start cap was good at the end of the motor shaft but run cap failed and didn't kick in. Did you try to spin the shaft by finger? Sometime the impeller gets clogged or the shaft in that area sticks in on older motors. I don't have burnt winding very much cause there is a thermal cutoff protection and the system is frequently turned off by the customer if it doesn't run.

  • @etmeyutub
    @etmeyutub ปีที่แล้ว

    I can't tell what that symbol is you are turning your meter too. Am I blind? I don't recognize it. It does not look like I have that on my meter. Can someone explain?

    • @Inyopools
      @Inyopools  ปีที่แล้ว

      The meter you're using may not have the ability to test capacitance.

    • @etmeyutub
      @etmeyutub ปีที่แล้ว

      @@Inyopools yep. figured that out since the question