Natural Gas Dehydration System (Using Glycol)

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ส.ค. 2024

ความคิดเห็น • 15

  • @bestfriendhank1424
    @bestfriendhank1424 7 หลายเดือนก่อน +2

    Thanks for the video. In depth and interesting, but not a bore.

  • @stijn2472
    @stijn2472 4 หลายเดือนก่อน +1

    Incredibly interesting video. Thanks!

  • @KB-ok5ob
    @KB-ok5ob 2 ปีที่แล้ว +1

    Holy smokes!
    This was sooooo good.
    I recently interned at a midstream company (natural gas) & I wish I would of found this sooner.
    You touched on a lot of key items and explained them in a nice simple way.
    Keep up the good work!

  • @machmemo7
    @machmemo7 ปีที่แล้ว +1

    Love to see a video on the building or the maintanence of this systems

  • @mohamedwhba9724
    @mohamedwhba9724 2 ปีที่แล้ว +2

    great video , educational and simple

  • @thiagomarins1231
    @thiagomarins1231 ปีที่แล้ว

    Very good.
    Congratulations.

  • @kashifayub2189
    @kashifayub2189 10 หลายเดือนก่อน

    Excellent

  • @kikoiekiko7440
    @kikoiekiko7440 3 หลายเดือนก่อน

    hey quick question whats the different between a glycol contactor vs stand alone scrubber? the scrubber just takes the water out?

  • @francescobaruffi999
    @francescobaruffi999 2 ปีที่แล้ว +1

    Fascinating video, as a crude hauler sometimes I open a crude holding tank thief hatch and there's so much gas/pressure it blows my hard hat off my head. Always happens on hot "fresh" oil during flowback immediately following frac completion, and or hot summer days, would it be accurate to say this is natural gas which hasn't had the time to burn off via flare stacks, the absence of a dehydration system, or BTEX's pumped back in, or just some other pressure issue within the holding tank battery separation /dehydration system?

    • @OilfieldBasics
      @OilfieldBasics  2 ปีที่แล้ว

      Good question. That's largely going to be what we would call flash gas. As the oil dumps to the tanks from a higher pressure vessel, gas comes out of solution. Warm temperatures would also cause more gas to come out of solution from the oil. The gas should get combusted or recovered, but on warm days or days where production is high, the average tank pressure might be higher. This has nothing to do with a dehydration system. Check out our video on Flash Gas and Vapor Recovery - th-cam.com/video/l5wTR2neidA/w-d-xo.html

    • @francescobaruffi999
      @francescobaruffi999 2 ปีที่แล้ว +1

      Just checked it out, nailed it. 👌 grateful for your videos, keep em up !

  • @slomnim
    @slomnim 2 ปีที่แล้ว

    Woah

  • @snipper496
    @snipper496 ปีที่แล้ว

    What we called tube inside the reboiler