@lipunayak2180 Comment krne k loye aapka shukriya......Luminous Optimus 2800 Inverter 2 battery matlab 24 VDC wala hai. Iske charger ki maximum charging capacity 21A hai.....Aur kisi bhi battery ko charge krme ke liye, uske AH rating ke 10% ka charger capacity hona jaruri hai....To 260 ah ki battery ko charge krne ke 26 A ka charger jaruri hai. Aap isko 210 Ah ki battery laga skte hai as per standard. Agar aap 260 Ah ki batterg lagate hai to battery dhire dhire charge hona ya charger kharan hone ki sambhavna jyada hai. Kabhi kabhi aapko warranty me bhi OEM se iski repairing na hone ki samasya ka samna krna pd sakta hai agar aap charger ke capacity ke bahar ka battery lagate ho to. ...jyada jaankari k liye kripaya 9372217661 ya 9820710392 pe sampark kare...Dhanyawad
Thanks for your comment..... Iska DC bus 24 VOlt ka hai to aap 2 battery series me connect kr sakte hai....agar aap 100 ah ka double set connect karoge to battery Ah capacity double ho jayega isases aapka back up time badhega .....iska charger 80Ah-250 Ah ki battery ko support karega to aap nishchint ho ke 2 battery parrallel with 2 set series connect kr sakte hai.
It's only an inverter not a UPS. Eventhough it has UPS function, my PC restarts on every power failure. The overload alarm starts beeping at 1760W itself. Has poor efficiency. Not at all recommended.
Thanks for your valuable comment.... Yes this is not UPS its Inverter..To avoid Shutdown of your PC during power failure you suppose to go for online UPS instead of Inverter.
Thanks for your comment....Ji jabtak inverter sahi se kam kr rha hai black switch ka position normal pe rahega...agar inverter me kuchh problem aati hai aur aapko output nhi milta hai to aapko is switch ka position bypass pe krna hai....for more information or any requirement you can call us on 98207 10392 or 9372217661
Asech video bnavat rha bhau
@@shortfast123 Dhanyawad मित्रा
Keep it up Costa😀
❤❤👍🏻👍🏻
Bhaiya kya is inverter per Exide ka 260 ah double battery chalega please jabab dejiye
@lipunayak2180 Comment krne k loye aapka shukriya......Luminous Optimus 2800 Inverter 2 battery matlab 24 VDC wala hai. Iske charger ki maximum charging capacity 21A hai.....Aur kisi bhi battery ko charge krme ke liye, uske AH rating ke 10% ka charger capacity hona jaruri hai....To 260 ah ki battery ko charge krne ke 26 A ka charger jaruri hai. Aap isko 210 Ah ki battery laga skte hai as per standard. Agar aap 260 Ah ki batterg lagate hai to battery dhire dhire charge hona ya charger kharan hone ki sambhavna jyada hai. Kabhi kabhi aapko warranty me bhi OEM se iski repairing na hone ki samasya ka samna krna pd sakta hai agar aap charger ke capacity ke bahar ka battery lagate ho to. ...jyada jaankari k liye kripaya 9372217661 ya 9820710392 pe sampark kare...Dhanyawad
@@costapowerindusriespvtltd5183 thanks for your valuable feedback 🙏🙏
100ah ki 4 battry use kr skta he kya
2 serias or 2 parreal
Thanks for your comment..... Iska DC bus 24 VOlt ka hai to aap 2 battery series me connect kr sakte hai....agar aap 100 ah ka double set connect karoge to battery Ah capacity double ho jayega isases aapka back up time badhega .....iska charger 80Ah-250 Ah ki battery ko support karega to aap nishchint ho ke 2 battery parrallel with 2 set series connect kr sakte hai.
@@costapowerindusriespvtltd5183thank You for replying
It's only an inverter not a UPS. Eventhough it has UPS function, my PC restarts on every power failure. The overload alarm starts beeping at 1760W itself. Has poor efficiency. Not at all recommended.
Thanks for your valuable comment.... Yes this is not UPS its Inverter..To avoid Shutdown of your PC during power failure you suppose to go for online UPS instead of Inverter.
Which PSU/SMPS you're using in your PC?
@@miningrig19569 vguard
2500 * 0.6 = 1500w you should use , they give 2000w
Hi... Iska bypass switch humesha.... Normal mode pe rahega.....?
Thanks for your comment....Ji jabtak inverter sahi se kam kr rha hai black switch ka position normal pe rahega...agar inverter me kuchh problem aati hai aur aapko output nhi milta hai to aapko is switch ka position bypass pe krna hai....for more information or any requirement you can call us on 98207 10392 or 9372217661
Battery backup nahi de raha hai q same inveter hai