- 185
- 145 129
Costa Power Indusries Pvt Ltd
India
เข้าร่วมเมื่อ 3 มี.ค. 2019
Costa Power Industries Pvt Ltd is a global leader in providing, designing, serving that enables in ups, ups battery, ups amc, inverter, stabilizer, server room, data centers, battery back up solution for office, commercial centers.
For more details about Costa Power Industries Pvt Ltd, go through the below links:
For more details about Costa Power Industries Pvt Ltd, go through the below links:
APC UPS Review & Setup Guide | Best Uninterruptible Power Supply?
#APCUPS #PowerBackup #UPSSetup #UninterruptiblePowerSupply #HomeOfficeTech #TechReview #PCBackup #APCReview #PowerSolutions #TechTips #viralvideo
มุมมอง: 92
วีดีโอ
Guide to Replacing Capacitors in Industrial UPS Systems for Optimal Performance #ups
มุมมอง 14019 ชั่วโมงที่ผ่านมา
Guide to Replacing Capacitors in Industrial UPS Systems for Optimal Performance #ups #capacitor Learn how to identify when capacitors in your industrial UPS system need replacement, understand the replacement process, and ensure optimal performance and longevity of your power backup system. This comprehensive guide covers troubleshooting tips, safety precautions, and benefits of timely maintena...
Emerson UPS: Reliable Power Solutions for Home and Business | Complete Overview #upsbattery
มุมมอง 62วันที่ผ่านมา
Emerson UPS: Reliable Power Solutions for Home and Business | Complete Overview #upsbattery Looking for a reliable power backup solution? The Emerson GXT MT PLUS 10 KVA UPS is designed for seamless performance, providing uninterrupted power for your critical devices. Why Choose Emerson GXT MT PLUS 10 KVA UPS? Perfect for data centers, server rooms, and industrial applications, this UPS ensures ...
Choosing the Right UPS: A Beginner's Guide
มุมมอง 69หลายเดือนก่อน
Choosing the Right UPS: A Beginner's Guide
Tips for installing vertiv Hipulse-U UPS
มุมมอง 3723 หลายเดือนก่อน
Tips for installing vertiv Hipulse-U UPS
unboxing and review of Schneider Electric Galaxy 5500 120 KVA UPS #ups #watchnow #electrical
มุมมอง 7593 หลายเดือนก่อน
unboxing and review of Schneider Electric Galaxy 5500 120 KVA UPS #ups #watchnow #electrical
ganapati visarjan #visarjan #ganapati #vlog #ups #electrical #trending #watchnow
มุมมอง 703 หลายเดือนก่อน
ganapati visarjan #visarjan #ganapati #vlog #ups #electrical #trending #watchnow
wiring a 10 kva inverter: safety tips and tricks #electrical #backup #viral #batterybackup #inverter
มุมมอง 453 หลายเดือนก่อน
wiring a 10 kva inverter: safety tips and tricks #electrical #backup #viral #batterybackup #inverter
Ganpati Festival celebration #ganpati #ganpatibappamorya #decoration
มุมมอง 2473 หลายเดือนก่อน
Ganpati Festival celebration #ganpati #ganpatibappamorya #decoration
Luminous 10KVA inverter #electrical #upsbattery #viralvideo
มุมมอง 1023 หลายเดือนก่อน
Luminous 10KVA inverter #electrical #upsbattery #viralvideo
A tutorial on how to maintain a hitachi ups#vlog #viral #upsbattery #backup #battery #powerbackup
มุมมอง 2624 หลายเดือนก่อน
A tutorial on how to maintain a hitachi ups#vlog #viral #upsbattery #backup #battery #powerbackup
#upsbattery #electrical #powerbackup #vlog
มุมมอง 704 หลายเดือนก่อน
#upsbattery #electrical #powerbackup #vlog
How to install 60 KVA BPE UPS #upsbattery #installups #ups #trending #electrical
มุมมอง 1.8K5 หลายเดือนก่อน
How to install 60 KVA BPE UPS #upsbattery #installups #ups #trending #electrical
UPS battery installation with parallel UPS connection. #viral #electrical #instaviews #battery #...
มุมมอง 1116 หลายเดือนก่อน
UPS battery installation with parallel UPS connection. #viral #electrical #instaviews #battery #...
UPS battery installation with parallel UPS connection. #viral #electrical #instaviews #battery #vlog
มุมมอง 1976 หลายเดือนก่อน
UPS battery installation with parallel UPS connection. #viral #electrical #instaviews #battery #vlog
UPS battery installation 3kVA Microtek UPS & 26AH Battery #viral #vlog #instaviews #viewsfordays
มุมมอง 2136 หลายเดือนก่อน
UPS battery installation 3kVA Microtek UPS & 26AH Battery #viral #vlog #instaviews #viewsfordays
ups systems | ups battery dealers | ups dealers in mumbai | ups amc services #viral #upsdealers #ups
มุมมอง 676 หลายเดือนก่อน
ups systems | ups battery dealers | ups dealers in mumbai | ups amc services #viral #upsdealers #ups
UPS Battery installation - Exide nxt battery overnight installation by CPIPL #vlog #viral #battery
มุมมอง 3097 หลายเดือนก่อน
UPS Battery installation - Exide nxt battery overnight installation by CPIPL #vlog #viral #battery
Vertiv S400D 20 Kva UPS Operation| SuperD UPS Vertiv ups dealers | #vlogger #vblog #Vertiv
มุมมอง 1.4K11 หลายเดือนก่อน
Vertiv S400D 20 Kva UPS Operation| SuperD UPS Vertiv ups dealers | #vlogger #vblog #Vertiv
Diwali festival celebration at CPIPL #vlogs #vblog #ups #festival #mumbai
มุมมอง 120ปีที่แล้ว
Diwali festival celebration at CPIPL #vlogs #vblog #ups #festival #mumbai
Ganpati festival celebration at CPIPL #vlogs #vblog #ups #festival #mumbai
มุมมอง 151ปีที่แล้ว
Ganpati festival celebration at CPIPL #vlogs #vblog #ups #festival #mumbai
Doing Emerson UPS AMC Service | UPS Battery Dealers | UPS AMC Service |#vlogs #vblog #Emerson ups
มุมมอง 449ปีที่แล้ว
Doing Emerson UPS AMC Service | UPS Battery Dealers | UPS AMC Service |#vlogs #vblog #Emerson ups
How to Perform Indian Make UPS system? Top ups battery dealers | Industrial ups system #vlogs #vblog
มุมมอง 360ปีที่แล้ว
How to Perform Indian Make UPS system? Top ups battery dealers | Industrial ups system #vlogs #vblog
How to function Emerson S400D 20KVA UPS? Best ups System | Vertive Industrial ups |#vlogs#vblog
มุมมอง 1.1Kปีที่แล้ว
How to function Emerson S400D 20KVA UPS? Best ups System | Vertive Industrial ups |#vlogs#vblog
How to repair UPS system? #UPS Repairs vlogs #vblog #electrical #ups repair Service #vblog UPS
มุมมอง 205ปีที่แล้ว
How to repair UPS system? #UPS Repairs vlogs #vblog #electrical #ups repair Service #vblog UPS
How to Install Luminous Optimus 2800Watts Inverter....#vlogs #vblog #luminousinverter
มุมมอง 4.3Kปีที่แล้ว
How to Install Luminous Optimus 2800Watts Inverter....#vlogs #vblog #luminousinverter
How to Install BPE UPS with exide Battery | ups battery dealers | ups dealers in mUmbai | ups amc
มุมมอง 2.9Kปีที่แล้ว
How to Install BPE UPS with exide Battery | ups battery dealers | ups dealers in mUmbai | ups amc
How to Install Vertiv make GXT MT 10 kva LB UPS ..UPS Dealers/UPS AMC/UPS repair #vertiv#vlogs
มุมมอง 2.2Kปีที่แล้ว
How to Install Vertiv make GXT MT 10 kva LB UPS ..UPS Dealers/UPS AMC/UPS repair #vertiv#vlogs
How to install Hitachi 3kva UPS ups dealers | ups battery dealers | ups dealers in Mumbai | ups amc
มุมมอง 9Kปีที่แล้ว
How to install Hitachi 3kva UPS ups dealers | ups battery dealers | ups dealers in Mumbai | ups amc
Nice 🎉
Hi. you have an idea how the LIEBERT VERTIV NXC 30 KVA inverter ignition steps
thank for your valuable comment.... kindly connect with us on 9372217661 or 9820710392 we will definitely help you out.
Hi. you have an idea how the NXC 30 KVA inverter ignition steps
yes please call us on 9372217661 or 9820710392
खूप छान माहिती सांगताय तुम्ही
@@AmolGosavi-h5c आपला खुप आभारी आहे.
Dombivli East chi branch aahe ka
@@saichavan4944 Yes
Very nic
@@anijee-u5e Thanks for your valuable comment
Sir iske invter on kar k code bata do
Thanks for your comment....Call me on 9372217661 or 9820710392
Thank you sir for your valuable video......sir one thing what is the default dc voltage of this ups and is there any password.
@jayantaroy1963 thank you for your valuable comment...Default DC voltage is set for 32 nos battery system...13.50 per battery charving voltage set to 432 VDC.....Yes system DC voltage setting changes with number of battery setting through mimic display and is done by OEM software only...
How much
Thanks for comment...please send ur enquiry on sales@upsbatteriesindia.com or call us on 9372217661
Output light is not blowing but ups is on. How to fix it?
Thanks for your comment...please connect with us on 9372217661 definitely we will help you out.
Koi Delhi mein ups engineer hai to mera apne company mein lag le kyu mein bhi ek ups engineer hu
Sir mein bhi ek ups engineer hu abhi mera pass job nhi hai aap pass job mil sakte hai
Thanks for your valuable comment.
Great 🎉
I am also working same field.
pls make video about connection about 2 volt 500ah 110 volt ups use on industrial use with connection.
Thanks for your comment....You mean 110V DC UPS? Please connect with us on 9372217661.
Brother give me number i want to talk you
@@mohammedsalahuddin8166 call me on 9372217661
Ups pehle ON kar ke karte to spark nhi aati
How on inverter
Fir se ek baar aapko dhanyawad help ke liye😊
Bahut Sunder 😊
Thank you For more details about Costa Power Industries Pvt Ltd, go through the below links: Website: www.upsbatteriesindia.com TH-cam Channel: studio.th-cam.com/users/videolZh8Ap1uQHg/edit
What is "noa" and "cf" in side display .. meanings
Sir. Numeric company ka online ups battery par rusht aur corbon ki vajah se battery ka error dikha raha hai kripya karke iske baare me. Bataye. Good morning 🌞
@@pintugupta9148 Thanks for your valuable comment...Please contactvus on 9372217661 or 9820710392
Shukriya sir aap ka help karne ke liye. Online ups ke pcb bor ke baare me jankari chahiye tha. Ki ye jarurat padne par kaise aur kaha par milega.
@@pintugupta9148 Aap har ups ka spare parts hamare pass milega....kabhi jarurat pade to contact kr lema 9372217661 or 9820710392
@@costapowerindusriespvtltd5183 thik hai
Nice
@@tejasingale4412 Thank you for your valuable comment
😊
Good work team,keep rocking🙂🙂
Hy
Libert ITA 20 kva ka install karne ke sambhand me
Sir aap ki help chahiye
@@pintugupta9148 call on 9372217661
@@pintugupta9148 Thanks for ur valuable reply.....call us on 9372217661 or 9820710392
@@costapowerindusriespvtltd5183 installation lagata hai cancel ❌ ho jayega Aaj kaafi barish ho rahi hai mere yahan. Ruk haya to jaaunga
Barish ruk gaya to jaaunga.
@@pintugupta9148 ye bhi reply krke hi bataoge kya???
Out put short ckt, how to check
@@ANILKUMAR-uu2vi output short circuit ka alarm aapke load side me faulty ya defective equipment ki wajah se aata hai, aap agar output ka mcb off krke check kroge to ye alarm chala jayega ga ......distribution panel me separate mcb rahenge to trace out krna easy jayega ki konse circuit me problem hai...kabhi kabhi mobile charger ya power adapter ke kharab home se bhi ye alarm aa jata hai.
If we don't connect battery connector to the ups, then there will be display ON or the warning indicator will blink and no display on the panal
@rajnishkaloi8591 if you didn't connect battery connector, ups display will be turned ON through input AC supply but it will show alarm NC i.e for battery not connected and it will give you contineous beeping until battery not get connected.
backup?
@@hardikagrawal9068 HALF HOUR
5 min
@@bibhasroy9067 sir, can you please explain how it is 5 min
"Bypass volt not ok" इसका क्या?
@@atharvapowersys9997 System ka bypass supply source ka Fuse open rakha hai on customer demand, iocl, bpcl, hpcl aur bhi bahut sare clients ko inverter fail home ke baad ups apne system bypass yani raw source ka supply load ko na jane dene ki demand krte hai, in that case hum bypass supply off rakhte hai to ye alarm aata hai.
DC capacitor ki value kya hai super D 20kva
@@kunaltelangi2779 3300Uf 450V
Battery sidhi rakho bhai
Comment krne k liye aapka shukriya....Agar mai battery sidhe rakhta to connection complicated ho jate hai.....Koi baat nhi aapki ray ham next installation me use karenge....Thank you
Ismain external battery connector nhi hota hai alag se lag wana padta hai kya
1 kva se lekar 3 kva tak internal battery and external battery ke do alag alag model aate hai...internal battery model me external battery ke liye battery andar hi fix hoti hai isiliye bahar se connector nhi hote hai .....balki external battery model me ups k pichhe connector rehta hi hai
✨❣️
@@priyankamahadik2566 Thanks for your valuable comment
Bhaiya kya is inverter per Exide ka 260 ah double battery chalega please jabab dejiye
@lipunayak2180 Comment krne k loye aapka shukriya......Luminous Optimus 2800 Inverter 2 battery matlab 24 VDC wala hai. Iske charger ki maximum charging capacity 21A hai.....Aur kisi bhi battery ko charge krme ke liye, uske AH rating ke 10% ka charger capacity hona jaruri hai....To 260 ah ki battery ko charge krne ke 26 A ka charger jaruri hai. Aap isko 210 Ah ki battery laga skte hai as per standard. Agar aap 260 Ah ki batterg lagate hai to battery dhire dhire charge hona ya charger kharan hone ki sambhavna jyada hai. Kabhi kabhi aapko warranty me bhi OEM se iski repairing na hone ki samasya ka samna krna pd sakta hai agar aap charger ke capacity ke bahar ka battery lagate ho to. ...jyada jaankari k liye kripaya 9372217661 ya 9820710392 pe sampark kare...Dhanyawad
@@costapowerindusriespvtltd5183 thanks for your valuable feedback 🙏🙏
Great work...keep going
Sir Why You Not Used Changeover Mcb..
Thank you for your comment....Changeover MCB comes under electrical scope which is in client scope by default so not to use changover MCB is at all his own decision. .....Thanks again to suggest your ideas and improve us.
Happy independence day 🎉
@ganeshkhade897 Thank you sir for your valluable comment....Wishing you and your family happy independence day
th-cam.com/video/hKqRAFXLuYA/w-d-xo.htmlsi=aFAmDXGhsif-haXH
shankar, i have Liebert NX 300kva UPS it does not power up on battery and showing BCB Close, send mw your whats app or any other platform so i could share pictures with you
@TalhaSid-k3l Thanks for your valuable comment....please comnect with us on 9372217661
👌👌👌👌
@@SajjadHussain-rg3he Thank you for your valuable comment
Sir this UPS user name password
Great work CPIPL and Shankar
Ups ko online se bypass kese kare
Displayy se off ka button jo do buttons k bich me hai usko 3 seconds tak press kro to inverter off ho jayega aur load bypass ho jayega..... is ups me maintenance ya manual bypass nhi hai
Sir aap kaha se hai
@chhotebhai-mn1wm ...Basically we are located in Mumbai .....But we have our services all over india along with our branches.
Sir ji aap ka number mil jayega
Sir ji aap ka number mil jayega
@@chhotebhai-mn1wm 9372217661 or 98207 10392
@@chhotebhai-mn1wm 9372217661
Inverter is not going to battery mode.
@biswajitroutray6680 ...Thanks for your comment...there might be battery faulty, check battery fuse, individual battery voltage on load, ...for more information connect with us 9372217661 or 98207 10392
Hello sir can you share us alarm details ALA 208 or service manual
Please reach us at 9372217661 or 9820710392
Bpe 60 kva ups connection batao sir
Thank you for your valuable comment....please call us on 9372217661
@amolingole3745 please be there as we are going to upload one new video for BPE 40 kva EPX model UPS installation very soon...will share you link once get upload